Game Ready 550550-03 User Manual

Manual is about: Physical Therapy Unit

Summary of 550550-03

  • Page 1

    This user’s manual is also available online in english, french, german, italian, japanese, spanish, portuguese, arabic, russian, dutch, hungarian and turkish at www.Gameready.Com under support. Model numbers 550550-03, 550550-03-rn, 550550-53 g r pro ® 2.1 c o n t r o l u n i t user’s manual 53.

  • Page 2

    Slee p time time run ice bath temp . Pres sure off low med high avg. Wrap tem p. 55/1 3 50/1 0 45/7 40/5 ºf/ºc d e s c r i p t i o n o f t h e g r p r o 2 . 1 s y s t e m the following items are included in your grpro ® 2.1 system: sleep time time run pressure off low med high 55/13 50/10 45/7 40/5 ...

  • Page 3

    En-1 introduction to game ready _________________________________ 2 detailed instructions for use _________________________________ 3 modes of operation _____________________________________ 3 buttons ________________________________________________ 3 adjusting temperature __________________________...

  • Page 4

    En-2 based in concord, california, and founded in 1998, game ready ® (coolsystems, inc.) is a best-in-class sports medicine and orthopedic medical device that helps athletes and patients recover from injury or orthopedic surgery. The game ready system with accel ® technology gives healthcare provide...

  • Page 5

    En-3 do not use this device without your physician’s specific recommendations for the frequency and duration of your treatments. The most common recommendation is to use cold therapy at least 4 times a day, for approximately 30 minutes each time, with at least a 30-minute break between treatments. W...

  • Page 6

    En-4 adjusting temperature to adjust the temperature being applied during treatment, simply turn the temperature knob towards 3 snowflakes for the maximum amount of cold, or towards 1 snowflake for the least amount of cold. Notice that as you adjust the knob, the “target temperature” on the display ...

  • Page 7

    En-5 pressure: off low med high off low med high off low med high off low med high when selecting a program: sleep time time run pressure off low med high 55/13 50/10 45/7 40/5 ºf/ºc target temperature actual temperature displays pressure. Displays amount of time unit will run. Displays amount of ti...

  • Page 8

    En-6 operating the system to operate your grpro 2.1 system, you need: • control unit filled with ice and water as indicated by the fill line labels within the reservoir. Optimal performance is achieved by first adding 1.5 liters of water, and then filling the reservoir to the top with ice. • game re...

  • Page 9

    En-7 4 place the control unit in the location where you plan to use it. The control unit should only be used in the upright orientation as shown. The control unit will leak if placed on its side. 2 add water to fill-line indicated on label within the reservoir. Do not overfill. Add ice to top of res...

  • Page 10

    En-8 6 connect the larger end of the connector hose (with the red button) to the control unit. Make sure you hear it click. To disconnect, simply press the red button and remove the connector from the control unit. 7 apply the selected wrap (consult the use guide accompanying each wrap for applicati...

  • Page 11

    En-9 9 select the operating mode. You can choose either manual mode or program mode. Manual mode allows you to customize the time and pressure settings. Program mode allows you to select one of six automated programs that provide treatment for a set time interval then “sleep” (providing no treatment...

  • Page 12

    En-10 control unit the exterior of the control unit and the visible interior surfaces of the reservoir can be cleaned with a soft cloth and one of the following cleaning agents: • mild detergent • 70% isopropyl alcohol • 100% simple green ® • quaternary ammonium (such as virex ® – typically only fou...

  • Page 13

    En-11 connector hose the surface of the connector hose can be cleaned using a soft cloth and one of the following: • mild detergent • steri-fab ® • 70% isopropyl alcohol • we do not recommend the use of quaternary ammonium (such as virex ® ) or cavicide. ® do not use : • phenolic-based disinfectants...

  • Page 14

    En-12 m a i n t e n a n c e the reservoir filter should be inspected, cleaned, and/or replaced as necessary. Other than maintaining the reservoir filter, no product service should be performed by the user. If your grpro 2.1 system requires service, in the u.S. Call game ready customer service at 1.8...

  • Page 15

    En-13 the grpro 2.1 control unit can be used with any of the following accessories: • any game ready wrap using atx series heat exchangers (wraps made by any other manufacturer cannot be used with this system) • game ready supplied fsp group, inc. Power supply model fsp 030-rcam and hospital grade p...

  • Page 16

    En-14 g e n e r a l w a r n i n g s a n d c a u t i o n s warnings • follow the treatment recommendations of your health care practitioner for duration and frequency of use for this device. • improper placement or prolonged use of the game ready system could result in tissue damage. • during the cou...

  • Page 17

    En-15 cautions • to avoid the risk of electrical shock, do not remove any panels from the control unit. Opening the case will void the game ready warranty. For all servicing and repair, in the u.S. Call game ready customer service at 1.888.426.3732 (+1.510.868.2100); from outside of the u.S. Please ...

  • Page 18

    En-16 protection against electric shock: the grpro 2.1 system is considered to be class i (protective earth) when connected to the fsp group, inc. Model fsp 030-rcam power supply. Protection against harmful ingress of water: this product provides ordinary protection against ingress of water. Polluti...

  • Page 19

    En-17 e l e c t r o m a g n e t i c c o m p a t i b i l i t y electromagnetic compatibility information according to iec/en 60601-1-2 table 1 for emissions guidance and manufacturer’s declaration – electromagnetic emissions the grpro 2.1 is intended for use in the electromagnetic environment specifi...

  • Page 20

    En-18 table 2 for transient electromagnetic immunity guidance and manufacturer’s declaration – electromagnetic immunity the grpro 2.1 is intended for use in the electromagnetic environment specified below. The customer or the user of the grpro 2.1 should assure that it is used in such an environment...

  • Page 21

    En-19 table 3 for rf electromagnetic immunity guidance and manufacturer’s declaration – electromagnetic immunity the grpro 2.1 is intended for use in the electromagnetic environment specified below. The customer or the user of the grpro 2.1 should assure that it is used in such an environment. Immun...

  • Page 22

    En-20 table 4 for rf immunity recommended separation distances between portable and mobile rf communications equipment and the gr pro 2.1 the grpro 2.1 is intended for use in an electromagnetic environment in which radiated rf disturbances are controlled. The customer or the user of the grpro 2.1 ca...

  • Page 23

    En-21 error what does it mean? What can i do? Air pressure sensor: the control unit has detected a problem calibrating the air pressure circuit on start-up. • this is most likely to occur if you have restarted the system with an inflated wrap attached. • detach the wrap, pressing it flat to expel th...

  • Page 24

    En-22 error what does it mean? What can i do? Under pressure: the control unit can’t reach its target maximum compression. This often indicates that there is a leak in the pneumatic compression circuit, either in the connector hose, wrap or control unit. Or it may occur because the hook and loop fas...

  • Page 25

    En-23 error what does it mean? What can i do? Self-test error – fluid circuit: the control unit has detected an electronic problem in the fluid circuit on start-up. • turn off the control unit. • turn the control unit back on and resume treatment. • if the problem persists, contact customer service....

  • Page 26

    En-24 manufacturer’s warranty coolsystems warrants that the grpro 2.1 control unit, if properly used, will be free from defects in material and workmanship for a period of two (2) years after the date the grpro 2.1 control unit was purchased. If the grpro 2.1 control unit, which is the subject of th...

  • Page 27

    En-25 ec rep emergo europe molenstraat 15 2513 bh, the hague the netherlands 0086 limitations of liability coolsystems’ responsibility under this, or any other warranty, implied or express, is limited to repair or replacement, as set forth above. These remedies are the sole and exclusive remedies fo...

  • Page 28

    Game ready control unit user’s manual pn 703995 rev b ©2014 coolsystems, inc. All rights reserved. Coolsystems ® , inc. 1800 sutter street, suite 500 concord, ca 94520 usa 1.888.Gameready (1.888.426.3732) +1.510.868.2100 www.Gameready.Com.