Ganz ZP-EPC10 Installation Manual

Manual is about: GANZ ZP-EPC10 Protocol converter

Summary of ZP-EPC10

  • Page 1

    Installation guide protocol converter zp-epc10 always read this manual before installing, starting up, operating, storing or otherwise handling any part of the system..

  • Page 2

    This installation guide, edition 01 – 05/2000, is valid for use with the the zp-epc10 protocol converter (year 2000 version).

  • Page 3: Introduction

    Contents introduction intended use 4 eu directives 4 identification plate 4 safety measures danger by electric current 5 installation 5 repair and maintenance 5 product description scope of supply 6 recommended accessories 6 summary of features 6 connections and switches 7 installation connections 8...

  • Page 4: Intended Use

    4 zp-epc10 introduction this installation guide is designed for the use of persons concerned with the installation and configuration of the protocol converter and any devices connected to it. Relevant international, national and – if applicable – local electronic engineering standards should be obse...

  • Page 5: Danger By Electric Current

    Zp-epc10 5 (05/2000) security measures safety measures danger by electric current • the device must be connected to the appropriate power supply. • only use a suitable adaptor (see technical data). • disconnect the adaptor from the mains supply when an error occurs. • only use the adaptor and device...

  • Page 6: Scope of Supply

    6 zp-epc10 product description scope of supply ❚ protocol converter zp-epc10 ❚ 4 screw clamps ❚ installation guide recommended accessories ❚ cv12 power supply available from cbc ❚ cable made to belden specifications summary of features the zp-epc10 protocol converter is designed to convert control s...

  • Page 7: Connections and Switches

    Zp-epc10 7 (05/2000) product description 1 power light lights up red when ready 2 addressing rotary switch adjustment to start address (hexadecimal in value) 3 addressing rotary switch adjustment to end address (hexadecimal in value) 4 options switches reserved for further extensions 5 power clamp s...

  • Page 8: Connections

    8 zp-epc10 installation z caution! The device is intended for indoor use. Do not expose it to either extreme tem- peratures or extreme humidity at any time and choose its setup site accord- ingly. The ambient temperature must fall within the range from 5 to 40 °c at all times, the relative humidity ...

  • Page 9

    Zp-epc10 9 (05/2000) installation when the device is switched off, internal relays produce direct connections between command (input) and command (output), as in between answer (input) and answer (output) so that the signals are transmitted transparent between the remaining devices. Use belden cable...

  • Page 10: Configuration

    10 zp-epc10 configuration termination if you are using several units in a daisy chain configuration (rs422 or rs485), you must terminate the end-connectors with a resistor equivalent to the cable impedance, otherwi- se the system may not communicate properly. The factory settings for the protocol co...

  • Page 11

    Zp-epc10 11 (05/2000) installation addressing the system needs to be able to address every individual dome camera separately. This is done by assigning a unique address to each camera in a daisy chain. The protocol con- verter manages camera addressing for the multiplexer. Rotary selectors on the fr...

  • Page 12: Switching On and Off

    12 zp-epc10 example 2: 45 cameras in the system, using addresses 1 to 45 cameras 1 to 31 are connected to the first converter, 32 to 45 are connected to a second unit. First converter: selector 1 to position 0, selector 2 to position 1 (= address 1) selector 3 to position 1, selector 4 to position f...

  • Page 13: Cleaning

    Zp-epc10 13 (05/2000) repair and maintenance care and maintenance cleaning z warning! Never use alcohol, solvents, abrasive or corrosive cleaning agents for cleaning. These can damage the body of the device or scratch the polished finish. Use only a damp cloth. ❚ clean the device on the outside only...

  • Page 14

    14 zp-epc10 appendix appendix conversion table for hexadecimal addresses dec hex dec hex dec hex dec hex dec hex dec hex dec hex dec hex 1 01 33 21 65 41 97 61 129 81 161 a1 193 c1 225 e1 2 02 34 22 66 42 98 62 130 82 162 a2 194 c2 226 e2 3 03 35 23 67 43 99 63 131 83 163 a3 195 c3 227 e3 4 04 36 24...

  • Page 15

    Zp-epc10 15 (05/2000) appendix typical system configurations system with 12 smd cameras • connect the first protocol converter directly to the jack labelled rcvrs (j4) on your cec c328. • make your selection for the address range, between 1 (lower address) and 12 (upper address). • assign addresses ...

  • Page 16

    16 zp-epc10 appendix system with 45 smd cameras and 2 protocol converters • connect the first converter directly to the jack labelled rcvrs (j4) on your cec c328. • connect the second converter to the rcvrs jack of the first converter. • make your selection for the address range on the first convert...

  • Page 17

    Zp-epc10 17 (05/2000) appendix system with 3 smd cameras and 3 rs422 receivers (e.G. Cec vsd, cec ptr) • connect the first converter directly to the jack labelled rcvrs (j4) on your cec c328. • connect other rs422 receivers (e.G. Cec vsd) to the converter’s rcvrs jack. • assign addresses 1 to 3 to t...

  • Page 18: Meaning of Function Keys

    18 zp-epc10 appendix meaning of function keys use the multiplexer keyboard to control the smd dome cameras. Note that some of the keys may perform functions that are different from those you are used to from other receivers (e.G. Cec vsd): cec c328 key smd camera function joystick pan, tilt zoom in ...

  • Page 19: Troubleshooting

    Zp-epc10 19 (05/2000) appendix troubleshooting the following table is meant to help you in reading failure situations correctly and possi- bly in finding a solution. If you cannot correct the malfunction on your own, please con- tact the customer services department of cbc. Technical data operating ...

  • Page 20

    Cbc (deutschland) gmbh hansaallee 191 d – 40549 düsseldorf t: +49 (0) 211 53 06 70 f: +49 (0) 211 53 06 71 80 cbc (europe) ltd. 7/8 garrick industrial centre, irving way gb – london nw9 6aq t: +44 (0) 208 732 33 12 f: +44 (0) 208 202 33 87 cbc (europe) ltd. Ufficio milano via carolina romani, 1/11 i...