Gardena 5500/3 Operating Instructions Manual - page 4
15
14
GB
GB
Fault Possible
cause
Remedy
8. Technical Data
5500/3 (Art. 1461)
6000/4 (Art. 1468)
Mains voltage /
mains frequency
230 V / 50 Hz
230 V / 50 Hz
Rated power
900 W
1,000 W
Max. delivery capacity
5,500 l/h
6,000 l/h
Max. pressure
3.0 bar
4.0 bar
Max. delivery height
30m
40m
Max. submersion depth
12m
12m
Power cable
15m H07 RNF
15m H07 RNF
Pump connection
33.3mm (G 1 female thread)
33.3mm (G 1 female thread)
Minimum submersion depth
on commissioning
50mm 70mm
Min./ max. cut-in height
430mm / 660mm
450mm / 680mm
Min./ max. cut-out height
115mm / 210mm
135mm / 230mm
Residual water level
25mm
25mm
Weight approx.
9.6 kg
10.0 kg
Fastening rope
length 15m / Ø 5mm
length 15m / Ø 5mm
Max. media temperature
35 °C
35 °C
9. Available accessories
GARDENA 2- / 4-Way Valve
For parallel connection for more than
one hose or connected devices.
Art. 8193 / 8194
GARDENA Fitting 3/4"
For 19mm (3/4") hoses.
Art. 1723
GARDENA Fitting 1"
For 25mm (1") hoses.
Art. 1724
GARDENA
For 13mm (1/2") hoses via the
Art. 1750
Pump Connection Set
GARDENA Connection System.
GARDENA Tap Connector
For 16mm (5/8") hoses via the
Art. (2)902
GARDENA Hose Connector
GARDENA Connection System.
Art. (2)916
GARDENA
For 19mm (3/4") hoses via the
Art. 1752
Pump Connection Set
GARDENA Connection System.
For any other malfunctions please contact the GARDENA service department.
Repairs must only be carried out by GARDENA service departments or specialist
dealers authorised by GARDENA.
v Unplug the mains plug and
clean the suction foot valve
(see 6. Maintenance).
Suction foot / inlet screens
clogged.
Delivery rate suddenly
decreases.
6. Maintenance
Do not use any corrosive or abrasive cleaning media.
1. Unscrew the 4 screws
8
with a screwdriver.
2. Remove the suction foot valve
9
with inlet screen from the
pump and clean it.
3. Attach the suction foot valve with the inlet screens
9
to the
pump and tighten the 4 screws
8
with washers
0
.
7. Troubleshooting
Fault Possible
cause
Remedy
v Disassemble check valve and
clean (see 3. Initial operation).
Check valve jammed.
v Check fuses and electrical
plug-in connections.
Power supply interrupted.
v Unplug the mains plug and
clean the suction foot valve
(see 6. Maintenance).
Observe max. media
temperature (35 °C).
Pump overheated:
Thermal protection switch
switched pump off due to
overheating.
v Unplug the mains plug and
clean the suction foot valve
(see 6. Maintenance).
Suction foot / inlet screens
clogged.
v Submerge pump deeper
(see 8. Technical Data /
Minimum submersion depth
on commissioning).
When starting the pump,
water height falls below the
min. water level.
v Unplug mains cable and
plug in again.
Air cushion in suction foot.
v Open pressure line
(e. g. bent pressure hose).
Air cannot escape as the
pressure line is closed.
The pump does not
deliver any water.
DANGER! Electric shock!
There is a risk of injury from electric shocks.
v Before eliminating faults, disconnect the
submersible pressure pump from the mains.
9
0
8
For safety reasons, a damaged turbine must only be
replaced by GARDENA Service.
DANGER! Electric shock!
There is a risk of injury from electric shocks.
v Before maintenance, disconnect the
submersible pressure pump from the mains.
Clean suction foot with
inlet screen: