Gardena C 2030 duo plus Operating Instructions Manual - page 9
9
GB
The Prog
ON
must be selected so that the watering programme
can start. With Prog
OFF
automatic watering is deactivated.
Prog
ON
/
OFF
can be independently selected for each valve.
Also with Prog
OFF
manual watering is possible.
1. Select Valve 1 (
ï
V1) or Valve 2 (V2
ð
) with the
▼-▲ button (V1/ V2) (if a programme was previously created
then the valve cannot be selected, the corresponding valve is
automatically selected).
2. Press Menu button 5 times [Level 6] (not necessary if a
programme was previously created).
3. Select Prog
ON
or Prog
OFF
with the
▼-▲ buttons and
confirm with the OK button.
For 2 sec. Prog
OK
is shown and then the display moves to
the Normal Display [Level 1].
Prog
ON
: The water computer has now been programmed, i.e. the
inbuilt valve opens and closes completely automatically and thus
waters at the programmed time.
B) Direct sensor control
:
Prerequisite : at least one GARDENA Soil Moisture Sensor is
connected (see 4. Initial Operation). Watering nights (20:00 –
06:00), if the sensor registers dry.
A previously set scheduled watering programme is stored but
not carried out.
1. Select programme for Valve 1 (
ï
V1) or Valve 2 (V2
ð
)
with the
▼-▲ buttons (V1/ V2).
2. Press Menu button 3 times.
Run Time
and the watering duration flash on the display.
3. Set watering duration hours with the
▼-▲ buttons (e.g.
0
hours) and confirm with the OK button.
Run Time
and the watering duration minutes flash on
the display.
4. Set watering duration minutes with the
▼-▲ buttons (e.g.
10
minutes) and confirm with the OK button.
Watering cycle flashes on the display.
5. Select direct sensor control
with the
▼-▲ buttons and
confirm with the OK button.
After each watering, a 2-hour watering pause is triggered in
order for the Soil Moisture Sensor to record the soil moisture.
Activate / deactivate
watering programme :
[Level 6]
3.
4.
5.