Gardenline GLGP 1003 Quick Manual

Summary of GLGP 1003

  • Page 1

    Priming plug connection adaptor for hose non-return valve emptying plug inlet outlet quick guide for glgp 1003 garden pump please read all instructions before using the pump 1. Overview quick guide glgp_1003_spk7:layout 1 24.06.2008 8:21 uhr seite 1.

  • Page 2

    2. Pump operation clamp for connection remove the plastic covers and insert the hose adaptors into the pump body tightly. Connect the suction hose and the delivery hose to the hose adaptors. The hoses should be fixed tightly by clamps, with no leakage of hose or connections. The hose and clamps are ...

  • Page 3

    Also connect the non-return valve to the suction hose with a clamp. 1. Put the non-return valve and suction hose into water. Please make sure the pump is higher than water level at least 300mm. 2. Remove the priming plug and fill water into pump body until it overflows. 3. Replace the priming plug, ...

  • Page 4

    Before storing the pump please remove emptying plug to empty the water from the pump body then replace the plug. Empty water from this hole. Eh 06/2008 (01) please read all instructions before using the pump quick guide glgp_1003_spk7:layout 1 24.06.2008 8:21 uhr seite 4.