  • Page 1

    I www garrettcom com . . Www garrettcom com . . Corporate headquarters garrettcom, inc. 47823 westinghouse dr. Fremont, ca 94539-7437 phone (510) 438-9071 fax (510) 438-9072 website: http://www.Garrettcom.Com email support@garrettcom.Com magnum 6kq managed field switch hardware installation and user...

  • Page 2: Magnum

    Magnum 6kq managed field switch installation & user guide 04/07) i www garrettcom com . . Magnum ™ 6kq managed field switch hardware installation and user guide part #: 84-00180z (rev. C) trademarks ethernet is a trademark of xerox corporation nebs is a trademark of telcordia technologies ul is a re...

  • Page 3

    Magnum 6kq managed field switch installation & user guide 04/07) ii www garrettcom com . . Contacting garrettcom, inc please use the mailing address, phone and fax numbers and email address listed below: garrettcom, inc. 47823 westinghouse dr. Fremont, ca 94539-7437 phone (510) 438-9071 fax (510) 43...

  • Page 4

    Magnum 6kq managed field switch installation & user guide 04/07) iii www garrettcom com . . Electrical safety requirements: 1. This product is to be installed only in restricted access areas (dedicated equipment rooms, electrical closets, or the like). 2. 48vdc products shall be installed with a rea...

  • Page 5

    Magnum 6kq managed field switch installation & user guide 04/07) iv www garrettcom com . . Table of contents .............................................................................. Page 1.0 specifications ............................................................................... 1 1.1 te...

  • Page 6

    Magnum 6kq managed field switch installation & user guide 04/07) v www garrettcom com . . 5.2.1a 6kq2-10st, 2@10mb mm fx-st “twist lock” module .......... 36 5.2.2 6kq2-msc, 2@100mb mm fx-sc “snap-in” module ............ 37 5.2.3 6kq2-sscl, 2 ports @100mbps sm fx-sc-type, sgl.M ........ 37 5.2.4 6kq...

  • Page 7: The Magnum Line

    Magnum 6kq managed field switch installation and user guide (04/07) www garrettcom com . . The magnum line industrial networking products "designed and manufactured in the usa" overview garrettcom, inc. Offers the premium-quality magnum ™ line of industrial conectivity products with industry-standar...

  • Page 8

    Magnum 6kq managed field switch installation and user guide (04/07) 1 www garrettcom com . . 1.0 specifications 1.1 technical specifications performance filtering / forwarding rate: ethernet(10mb):14,880 pps fast ethernet(100mb): 148,800 pps gigabit ethernet (1000mb): 1, 488,000 pps switching proces...

  • Page 9

    Magnum 6kq managed field switch installation and user guide (04/07) 2 www garrettcom com . . 1000base-sx, full-duplex, multi-mode(50 μm cable) - 550m 1000base-lx, full-duplex, single-mode(62.5 μm cable) -5km fiber multi-mode connector types supported: fiber port, st-type (twist-lock):fiber multi-mod...

  • Page 10

    Magnum 6kq managed field switch installation and user guide (04/07) 3 www garrettcom com . . Power consumption: 35 watts worst case (for a fully loaded fiber model) 12 watts typical (for a small 4 port copper-only model) dual dc power input (optional) a dual-source option is available for the 12vdc,...

  • Page 11

    Magnum 6kq managed field switch installation and user guide (04/07) 4 www garrettcom com . . 1.2 ordering information magnum managed field switch (16 ports max) model description magnum 6kq- 24vdc magnum 6kq managed field switch, base unit with 24vdc power supply and four 10/100 copper ports. May be...

  • Page 12

    Magnum 6kq managed field switch installation and user guide (04/07) 5 www garrettcom com . . Fiber-only slot c configuration choices 6kqf-4mt “4 ports” module, w/four 100mb mm 2km fx mtrj’s fiber ports 6kqf-4mlc “4 ports” module, w/four 100mb mm 2km fx lc’s fiber ports 6kqf-4slc “4 ports” module, w/...

  • Page 13

    Magnum 6kq managed field switch installation and user guide (04/07) 6 www garrettcom com . . 2.0 introduction 2.1 inspecting the package and product examine the shipping container for obvious damage prior to installing this product; notify the carrier of any damage that you believe occurred during s...

  • Page 14

    Magnum 6kq managed field switch installation and user guide (04/07) 7 www garrettcom com . . 2.2 product description - magnum 6kq field switch magnum 6kq managed field switches provide maximum configurability in their class. The fiber-rich 6kq can be configured with up to 12 100mb fiber ports and t...

  • Page 15

    Magnum 6kq managed field switch installation and user guide (04/07) 8 www garrettcom com . . The 6kq managed switches also provide poe options via power – inside poe modules on one of a, b or c slots and allows the users to select a wide option of combo poe modules to support 802.3af pd devices. See...

  • Page 16

    Magnum 6kq managed field switch installation and user guide (04/07) 9 www garrettcom com . . Alarm relay contacts provided on each magnum 6kq switch monitor the hardware and software through traps, providing a record of any losses of power signals and other user- defined software events. See section...

  • Page 17

    Magnum 6kq managed field switch installation and user guide (04/07) 10 www garrettcom com . . When on (half-duplex when off). The blinking act led indicates receiving activity on the port. A fiber cable must be connected into a sff port and the link (lk) indicator for that port must be on (indicatin...

  • Page 18

    Magnum 6kq managed field switch installation and user guide (04/07) 11 www garrettcom com . . Except they have the capability of providing power on each port to power up the pd devices, per the ieee802.3af poe standard. The power-pass-through poe modules are dependent upon the -48vdc input power to ...

  • Page 19

    Magnum 6kq managed field switch installation and user guide (04/07) 12 www garrettcom com . . 2.2.5 two -port 10 mb mm fiber st modules the 2-port @10mb st fiber modules behave the same as the 2@100mb st fiber modules except for the 10mb speed. The default setup on the 10mb fiber module is half-dupl...

  • Page 20

    Magnum 6kq managed field switch installation and user guide (04/07) 13 www garrettcom com . . That port when lit.The copper gigabit ports come with speeds indicating (10/100/1000mb) leds also. The operation of the gigabit sfp and 10/100/1000 rj-45 ports is as described for those port types above. Fo...

  • Page 21

    Magnum 6kq managed field switch installation and user guide (04/07) 14 www garrettcom com . . The switch sends industry standard (full-duplex only) pause packets out to the devices sending it packets to cause “flow control”. This tells the sending devices to temporarily stop sending traffic, which a...

  • Page 22

    Magnum 6kq managed field switch installation and user guide (04/07) 15 www garrettcom com . . 2.3 features and benefits „ managed switching for high performance ethernet lans magnum 6kq switches provide unicast non-blocking (all ports can run at full speed at once) performance with standard managed ...

  • Page 23

    Magnum 6kq managed field switch installation and user guide (04/07) 16 www garrettcom com . . 2.4 applications magnum 6kq field switches offer high performance, modularity and availability. They provide the flexibility of 100mbps fiber and copper ports as well as single or dual gigabit (1000mb) port...

  • Page 24

    Magnum 6kq managed field switch installation and user guide (04/07) 17 www garrettcom com . . Fiber media provide widespread options to the users to mix and match their legacy and advance network needs. The modularity of the 6kq managed field switches make them an attractive choice for use in applic...

  • Page 25

    Magnum 6kq managed field switch installation and user guide (04/07) 18 www garrettcom com . . Example 2. A managed network is needed to provide a redundant ring topology for maximum redundancy. In a network where any faulty cable, cable disconnection or power failure can bring the whole thing down, ...

  • Page 26: Example 3.

    Magnum 6kq managed field switch installation and user guide (04/07) 19 www garrettcom com . . Example 3. In another application in an industrial environment, a 12 port nebs compliant, -24vdc managed switch is required to meet the fiber and copper connections to cover the wider area of video cctv. Th...

  • Page 27

    Magnum 6kq managed field switch installation and user guide (04/07) 20 www garrettcom com . . For dc power input data, see appendix b. For dual source, see appendix c . The rugged metal case of the magnum 6kq will normally protect it from accidental damage in a lab or workplace setting. Maintain an ...

  • Page 28

    Magnum 6kq managed field switch installation and user guide (04/07) 21 www garrettcom com . . 2. Wipe clean the ends of the dual connectors with a soft cloth or lint-free lens tissue dampened in alcohol. Make certain the connectors are clean before connecting. Note: one strand of the duplex fiber op...

  • Page 29

    Magnum 6kq managed field switch installation and user guide (04/07) 22 www garrettcom com . . Note : it is recommended that high quality cat. 5 cable be used whenever possible in order to provide flexibility in a mixed-speed network, since 10/100 copper switched ports are auto-sensing for either 10 ...

  • Page 30

    Magnum 6kq managed field switch installation and user guide (04/07) 23 www garrettcom com . . 3.2.6 gigabit sfp (small form-factor pluggable) optical transceivers the small form-factor pluggable (sfp) is a compact optical transceiver used in optical communications for both telecommunication and data...

  • Page 31

    Magnum 6kq managed field switch installation and user guide (04/07) 24 www garrettcom com . . The various sfps transceivers supported by garrettcom 6kqs d slot are- 3.2.6a connecting fiber optic cable to sfp transceivers 1. Before connecting the fiber optic cable, remove the protective dust caps fro...

  • Page 32

    Magnum 6kq managed field switch installation and user guide (04/07) 25 www garrettcom com . . Fiber optic segment. 3. Find the transmit (tx) and receive (rx) markings on the sfp transceiver to verify the top side of it. Some of the transceiver marks arrow sign for up. 4. Position the sfp transceiver...

  • Page 33

    Magnum 6kq managed field switch installation and user guide (04/07) 26 www garrettcom com . . The din rail latching clips are mounted on the upper side corners of the 6kq unit. Two threaded holes are provided on the sides of 6kq for din- rail mounting purposes. See side view at the left. The require...

  • Page 34

    Magnum 6kq managed field switch installation and user guide (04/07) 27 www garrettcom com . . Air circulation and cooling of the rear part of the case. For best cooling of the 6kq, attach the metal brackets to metal (rather than wood or plastic). Attaching to metal helps conduct heat away from the 6...

  • Page 35

    Magnum 6kq managed field switch installation and user guide (04/07) 28 www garrettcom com . . Consumption will range from about 20 up to 35 watts, depending on the port quantity and types in the configuration.. When connecting the ethernet cabling, there is no need to power down the unit. Individual...

  • Page 36

    Magnum 6kq managed field switch installation and user guide (04/07) 29 www garrettcom com . . The alarm contacts are on the front left area (next to the dc power source) of the magnum 6kq unit and are green in color as shown in the picture. 3.6 6kq port module (6kpm) installation magnum 6kq switches...

  • Page 37

    Magnum 6kq managed field switch installation and user guide (04/07) 30 www garrettcom com . . The hyper terminal configuration is exactly the same as all other 6k-family managed switches. Please check the following url for details- http://www.Garrettcom.Com/techsupport/software/userguides/mns6k_cli....

  • Page 38

    Magnum 6kq managed field switch installation and user guide (04/07) 31 www garrettcom com . . To the other ports where it is not needed. Traffic needed for maintaining the un- interrupted operation of the network (such as occasional multi-cast packets) is forwarded to all ports. The magnum 6kq switc...

  • Page 39

    Magnum 6kq managed field switch installation and user guide (04/07) 32 www garrettcom com . . One frequently-used application for the managed magnum 6kq switch copper ports is to connect one of them using a fiber media converter to another switch in the network backbone, or to some other remote 100m...

  • Page 40

    Magnum 6kq managed field switch installation and user guide (04/07) 33 www garrettcom com . . Account for all devices and cable lengths within that domain. For magnum 6kq fast ethernet switched ports operating at 100mb half-duplex, the bit time delay is 50bt. 4.4 flow-control, ieee 802.3x standard m...

  • Page 41

    Magnum 6kq managed field switch installation and user guide (04/07) 34 www garrettcom com . . The following data has been collected from component manufacturer’s (agilent’s and lucent’s) web sites and catalogs to provide guidance to network designers and installers. Fiber port module speed, std. Mod...

  • Page 42

    Magnum 6kq managed field switch installation and user guide (04/07) 35 www garrettcom com . . 5.0 magnum 6kq managed field switch port modules this chapter describes each port module (pm), including appearance, functionality, and status displays. 5.1 inspecting the package and product this section a...

  • Page 43

    Magnum 6kq managed field switch installation and user guide (04/07) 36 www garrettcom com . . Each 6kq port module (pm) is individually described in the following sections. For the “6kf-series” fiber modules in slot c, the operational description is the same as the corresponding fiber modules config...

  • Page 44

    Magnum 6kq managed field switch installation and user guide (04/07) 37 www garrettcom com . . Switch, the fiber port supports fiber optic cable distances up the ieee-standard 10mbps distance limits, i.E., typically 2km at full-duplex and half-duplex. Each port has an activity (act) led indicating pa...

  • Page 45

    Magnum 6kq managed field switch installation and user guide (04/07) 38 www garrettcom com . . 5.2.4 6kq3-rjmsc “combo” 2@ 10/100mbps rj-45 ports and 1@100mbps multi-mode fx-sc-type, “snap-in” connector the magnum 6kq3-rjmsc is also a combo module equipped with 2 dual speed copper ports and 1 multi-m...

  • Page 46

    Magnum 6kq managed field switch installation and user guide (04/07) 39 www garrettcom com . . Black in color. The mt-rj’s small compact size connector and ease of connection make it a good choice for 100mbps “fiber-to-the-desktop” ethernet connectivity. When installed in a magnum 6kq switch, it supp...

  • Page 47

    Magnum 6kq managed field switch installation and user guide (04/07) 40 www garrettcom com . . 6kq switch, it supports fiber optic cable distances up to the ieee-standard 100mbps distance limits, i.E., typically 2km at full-duplex and 412m at half-duplex. The compact size of the lc connector reduces ...

  • Page 48

    Magnum 6kq managed field switch installation and user guide (04/07) 41 www garrettcom com . . Four-port rj-45 connector, and offers 10/100 full / half-duplex auto-negotiating capability on each port. The rj-45 connector is shielded to minimize emissions and will allow both unshielded twisted pair (u...

  • Page 49

    Magnum 6kq managed field switch installation and user guide (04/07) 42 www garrettcom com . . • in the case where the 48vdc power in not internally connected and no power is coming to the poe ports for some reason, all the poe port leds are on simultaneously to indicate a trouble condition. The port...

  • Page 50

    Magnum 6kq managed field switch installation and user guide (04/07) 43 www garrettcom com . . 5.2.12 6kq-blnk the 6kq-blnk is a blank face plate or cover plate that must be installed in any empty 6kq pm slot to maintain proper cooling air flow, safety, etc. Two screws underneath the front panel hold...

  • Page 51

    Magnum 6kq managed field switch installation and user guide (04/07) 44 www garrettcom com . . 6.2 when calling for assistance please be prepared to provide the following information. 1. A complete description of the problem, including the following points: a. The nature and duration of the problem; ...

  • Page 52

    Magnum 6kq managed field switch installation and user guide (04/07) 45 www garrettcom com . . 6.4 shipping and packaging information should you need to ship the unit back to garrettcom, please follow these instructions: 1. Package the unit carefully. It is recommended that you use the original conta...

  • Page 53

    Magnum 6kq managed field switch installation and user guide (04/07) 46 www garrettcom com . . Appendix b : dc power input b1.0 specifications for magnum 6kq switches, dc power at 24v and – 48v and 125v dc power input eachmagnum model 6kq managed switch requires dc power input, at either 24vdc, -48vd...

  • Page 54

    Magnum 6kq managed field switch installation and user guide (04/07) 47 www garrettcom com . . Other communication companies. In addition, many high availability equipment services, such as broadcasters, publishers, newspaper operations, brokerage firms and other facilities often use a battery backup...

  • Page 55

    Magnum 6kq managed field switch installation and user guide (04/07) 48 www garrettcom com . . 4. “complies with fda radiation performance standards, 21 cfr subchapter j.” or equivalent. 5. Fastening torque of the lugs on the terminal block: 9 inch-pound max. 6. To secure a centralized dc power sourc...

  • Page 56

    Magnum 6kq managed field switch installation and user guide (04/07) 49 www garrettcom com . . With the exception of the dual dc input power connections and the power supply, all specifications and configuration options for the magnum 6kq -48vdc, 12vdc, 24vdc, 125vdc and 250vdc models with this dual-...

  • Page 57

    Magnum 6kq managed field switch installation and user guide (04/07) 50 www garrettcom com . . Figure c5.0: dc dual-source, wiring connections with dual-source option. C5.0 installation this section describes the proper connection of the -48vdc, 12vdc, 24vdc, 125vdc and 250vdc dual source leads to th...

  • Page 58

    Magnum 6kq managed field switch installation and user guide (04/07) 51 www garrettcom com . . C6.0 ordering information for dual source power to order the optional dual-source power supply factory installed, add “dual- src-xxxv” as a separate line item following the product model. Example: magnum 6k...