Garland MO/WO 3500 Installation, operation and maintenance manual - Section 2

Manual is about: Induction Designer Series RTCS Module-Line Built-In Wok

Summary of MO/WO 3500

  • Page 1

    Installation, operation and maintenance manual this manual is updated as new information and models are released. Visit our website for the latest manual. Part number 4532880 1/15 induction designer series rtcs module-line built-in wok models.

  • Page 3

    3 safety notices safety notices definitions danger indicates a hazardous situation that, if not avoided, will result in death or serious injury. This applies to the most extreme situations. N warning indicates a hazardous situation that, if not avoided, could result in death or serious injury. , cau...

  • Page 4

    4 safety notices danger improper installation, adjustment, alteration, service, or maintenance of this appliance or installation of a damaged appliance can result in death, injury, equipment damage, and void the warranty. Never install damaged appliances, equipment, or accessories. Always have insta...

  • Page 5

    5 safety notices code n warning authorized service representatives are obligated to follow industry standard safety procedures, including, but not limited to, local/national regulations for disconnection / lock out / tag out procedures for all utilities including electric, gas, water and steam. Pers...

  • Page 6

    This page intentionally left blank.

  • Page 7: Table of Contents

    7 safety notices definitions.................................................................................................................................................3 descriptions of safety symbols and warnings on unit .............................................................3 disclaimer...

  • Page 8

    8 part number 4532880 1/15 table of contents (continued) section 3 operation proper induction cookware ............................................................................................28 wok pan .................................................................................................

  • Page 9: Section 1

    Part number 4532880 1/15 9 section 1 general information nomenclature and model numbers series function power (watt) model number mo = module line wo = wok line 3500 5000 8000 mo/wo 3500 mo/wo 5000 mo/wo 8000 warranty information visit www.Garland-group.Com to view and download a copy of your warran...

  • Page 10

    This page intentionally left blank.

  • Page 11: Section 2

    Part number 4532880 1/15 11 section 2 installation n warning safety and electrical requirements this appliance component requires additional features and components to comply with appliance and electrical standards. It is the responsibility of the customer and installer to interpret and comply with ...

  • Page 12

    12 part number 4532880 1/15 installation section 2 components induction generator, rtcsmp built-in line dual cook-tops (with built-in frame and ceran glass-top) x1 versions available: 3.5kw generator in/mo/wo3500 5.0kw generator in/mo/wo5000 8.0kw generator in/mo/wo8000 control unit, complete assemb...

  • Page 13

    Part number 4532880 1/15 13 section 2 installation critical requirements summary of operatig coditios maximum tolerance of nominal supply voltage +6 /-10 % supply frequency 50/60 hz ingress protection class ip x0 (protection by customer is required.) minimal diameter of induction pan 5” (12cm) maxim...

  • Page 14

    14 part number 4532880 1/15 installation section 2 electrical compartmet for personal safety and to protect the induction unit and wiring, we recommend isolating the electrical components and wires in separate electrical compartments inside the cabinet (figure b). The illustration below shows a simp...

  • Page 15

    Part number 4532880 1/15 15 section 2 installation istallatio clearace dager risk of fire/shock/equipment failure. All minimum clearances must be maintained. Do not obstruct vents or openings. Installation clearance – components b a a b b b b b b b b a cable bend / connection clearance (minimum) b a...

  • Page 16

    16 part number 4532880 1/15 installation section 2 locatio requiremets , caution do not position the air intake vent near steam or heat exhaust of another appliance. • the induction unit must be installed securely in a suitable non-flammable electrical enclosure (closed counters). • allow easy acces...

  • Page 17

    Part number 4532880 1/15 17 section 2 installation wok bowl, coil carrier, shield plate and generator installation dimesios: rtcs mo/wo shield plate ad geerator 12.24” (311 mm) 13.07” (332 mm) 7.17” (182 mm) 5.71” (145 mm) 0.79” (20 mm) 14.21” (361 mm) 3.82” (97 mm) 12.24” (311 mm) 12.24” (311 mm) 8...

  • Page 18

    18 part number 4532880 1/15 installation section 2 dimesios: coil carrier ad moutig coil carrier note: fasteners are not provided unless otherwise specified. 8 pactan (silicone seal) silicone gasket ceran bowl counter surface (5x2 mm, x1, provided) coil carrier flange lock nut (m5, x4) washer (5/15 ...

  • Page 19

    Part number 4532880 1/15 19 section 2 installation couter-top cut-out dimesios the opening for the wok bowl is to be fabricated with a slanted flange. The exact dimensions are listed in this section. This flange ensures the wok pan will sit properly without touching the ceran glass surface. Typical ...

  • Page 20

    20 part number 4532880 1/15 installation section 2 to install the induction unit: 1. Create a proper flange and opening on the counter-top. See “counter-top cut-out dimensions” on page 19 2. Install studs on the underside of the counter-top for mounting the coil carrier and the shield plate. See “di...

  • Page 21

    Part number 4532880 1/15 21 section 2 installation control unit installation • one control unit is provided for each cook zone. Note: install the operating unit in an upright position. Note: do ot dis-assemble the control unit or remove / loosen any screws on the control unit. Frot-mout method to mo...

  • Page 22

    22 part number 4532880 1/15 installation section 2 dimesios: cotrol uit 4.09" (104 mm) 4.09" (104 mm) 4.72" (120 mm) 4.72" (120 mm) 2.5" (63.5 mm) 3.62" (92 mm) 0.08" (2 mm) 0.55" (14 mm) 1.34" (34 mm) 2.28" (58 mm) 4.17" (106 mm) 4.72" (120 mm) 0 4.09" (104 mm) 4 x r 0.2” (5 mm) 4.09" (104 mm) Ø0.3...

  • Page 23

    Part number 4532880 1/15 23 section 2 installation electrical installation dager all electrical connections must be carried out by a certified electrical contractor, who is responsible for the correct rating and installation of the induction unit. The contractor has to comply with all legal safety r...

  • Page 24

    24 part number 4532880 1/15 installation section 2 electrical specificatios (cotiued) voltage power phase1 phase2 phase3 eutral earth 3.5kw model 208 v ac / 1ph / 60hz 3500w / 17a brown - - blue yellow-green 230 v ac / 1ph / 50hz 3500w / 15a brown - - blue yellow-green 240 v ac / 1ph / 60hz 3500w / ...

  • Page 25

    Part number 4532880 1/15 25 section 2 installation function test n warning before you start, read carefully and understand all safety and operational requirements in sections “safety notices” and “operation”. N warning ever leave an empty pan on cook-top induction units heat up empty pans very quick...

  • Page 26

    This page intentionally left blank.

  • Page 27: Seition 3

    Part number 4532880 1/15 27 disclaimer danger the on-site supervisor is responsible for ensuring that operators are made aware of the inherent dangers of operating this equipment. Dangerous electrical voltage danger if any part of the unit is cracked or broken, stop and immediately turn off the unit...

  • Page 28

    28 part number 4532880 1/15 operation section 3 notiie the reliability of the unit can only be guaranteed when it is used properly. The unit must always be operated within the limits / operating conditions provided in this manual. , caution metallic objects are heated up very quickly when placed on ...

  • Page 29

    Part number 4532880 1/15 29 section 3 operation material of cookware use cookware made of conductive and magnetic materials. If the pan bottom attracts a magnet, the pan is suitable for induction cooking. Look for cookware that is labeled “suitable for induction” or with an induction compatible symb...

  • Page 30

    30 part number 4532880 1/15 operation section 3 no pan no heat when a temperature is chosen, the induction unit only transmits energy when a pan is placed in the heating zone. If you remove the pan from the heating zone, power transfer to the pan stops immediately. If the pan is put back in the heat...

  • Page 31: Section 4

    Part number 4532880 1/15 31 disclaimer danger it is the responsibility of the equipment owner to perform a personal protective equipment hazard assessment to ensure adequate protection during maintenance procedures. N warning a good maintenance of the unit requires regular cleaning, care and servici...

  • Page 32

    32 part number 4532880 1/15 maintenance section 4 important rules on maintenance notice follow these rules to ensure reliable and repeatable performance of your induction unit: • keep kitchen temperature below 105°f (40°c). • never place your induction units next to any grease generating or heat gen...

  • Page 33

    Part number 4532880 1/15 33 section 4 maintenance weekly cleaning and maintenance notice inspect and clean air intake filter a dirty, blocked air intake filter blocks the air vent and will cause damages to the electronic components. Ensure to clean the filter at least once a week or as often as requ...

  • Page 34

    This page intentionally left blank.

  • Page 35: Section 5

    Part number 4532880 1/15 35 dangerous electrical voltage danger disconnect electric power at the main power disconnect for all equipment being serviced. Failure to disconnect the power at the main power supply disconnect could result in serious injury or death. The power switch does not disconnect a...

  • Page 36

    36 part number 4532880 1/15 troubleshooting section 5 note: if a problem arises during operation of your induction unit, follow the chart below before calling service. Routine adjustments and maintenance procedures are not covered by the warranty. Troubleshooting chart without error code / indicator...

  • Page 37

    Part number 4532880 1/15 37 section 5 troubleshooting troubleshooting chart with error code / indicator lamp flash code • unit equipped with an indicator lamp: the indicator lamp flashes to signal a specific problem area. Counting the number of short flashes after each long flash will give the possi...

  • Page 38

    38 part number 4532880 1/15 troubleshooting section 5 wearable parts list photo part number description 70000015 silicone seal pactan 7076, 310ml. For installation and water- tight seal..

  • Page 40

    Garland 1177 kamato road, mississauga, ontario, canada, l4w1x4 888-442-7526 www.Garland-group.Com to learn how manitowoc foodservice and its leading brands can equip you, visit our global web site at www.Manitowocfoodservice.Com, then discover the regional or local resources available to you. ©2014 ...