Garland SHGRIN3500 Installation And Operation Manual - 3.5  Operating Conditions

Manual is about: INDUCTION BUILT-IN GRIDDLES with RTCSmp (Real-time Temperature Control System multi-point sensing) TECHNOLOGY

Summary of SHGRIN3500

  • Page 1

    Part # 4532291 rev 2 (01/15/14) © 2013 garland commercial ranges limited installation and operation manual garland induction built-in griddles with rtcsmp technology real-time temperature control system multi-point sensing models: shgrin3500 shgrin5000 please read all sections of this manual and ret...

  • Page 2: Warranty

    Installation and operation manual garland rtcsmp induction built-in griddles 2 part # 4532291 rev 2 (01/15/14) warranty our warranty statements for induction products are available on-line. Please visit our website at www.Garland-group.Com/minisite/service to download the latest revision. If you mig...

  • Page 3: Contents

    Installation and operation manual garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 3 contents warranty ..................................................................................................................................... 2 using this manual ....................

  • Page 4: 1  Safety Requirements

    Safety requirements garland rtcsmp induction built-in griddles 4 part # 4532291 rev 2 (01/15/14) 1 safety requirements warning this product contains chemicals known to the state of california to cause cancer. Installation and servicing of this product could expose you to airborne particles of glass ...

  • Page 5

    Safety requirements garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 5 • the induction unit must only be used for cooking. Do no put any object other than food on the cooking surface. O never heat cookware on the griddle plate as this could damage the griddle plate. O do no...

  • Page 6: 2.1  Application

    Components and features garland rtcsmp induction built-in griddles 6 part # 4532291 rev 2 (01/15/14) 2 components and features 2.1 application the unique and patented rtcsmp install griddle-line units are specially engineered for cooking a large variety of food throughout the day. These compact grid...

  • Page 7: 3.1  Rating Plate

    Dimensions and technical specifications garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 7 3 dimensions and technical specifications 3.1 rating plate the rating plate lists important information such as model number, serial number, and electrical specifications. The rating ...

  • Page 8: 3.5  Operating Conditions

    Dimensions and technical specifications garland rtcsmp induction built-in griddles 8 part # 4532291 rev 2 (01/15/14) 3.5 operating conditions max. Tolerance of nominal supply voltage +6 /-10 % supply frequency 50/60 hz ingress protection class ip x0 maximum ambient temperature in storage > -4°f to +...

  • Page 9: 4  Installation

    Installation garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 9 4 installation important • kitchen designers and installation contractors are responsible for designing and installing correctly the appropriate support structures and ventilation system for the cooking equipme...

  • Page 10

    Installation garland rtcsmp induction built-in griddles 10 part # 4532291 rev 2 (01/15/14) • when installing the built-in unit, ensure the intake air and exhaust air are conducted separately. The in- take air and exhaust air must not mix. To avoid build-up of hot exhaust air inside the counter, draw...

  • Page 11

    Installation garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 11 the call-outs in the illustrations show: (c) air intake kit: the air duct can be connected from the unit to the bottom or to the side of the cabinet. (d) if there is no direct path to install the air intake du...

  • Page 12

    Installation garland rtcsmp induction built-in griddles 12 part # 4532291 rev 2 (01/15/14) template for holes and studs: c. Four (4) welding bolts d. Opening for service interface e. Holes for mounting control switch to install a control unit: 1. Use the dimensions from the template above to install...

  • Page 13

    Installation garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 13 4.5.2.2 drop-in mounting instructions important to protect the induction unit from water penetration, you must apply and bond the silicone adhesive properly to create a water-tight seal. Before you begin the i...

  • Page 14

    Installation garland rtcsmp induction built-in griddles 14 part # 4532291 rev 2 (01/15/14) to flush mount the griddle unit: important to protect the induction unit from water penetration, you must apply and bond the silicone adhesive properly to create a water-tight seal. Before you begin the instal...

  • Page 15

    Installation garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 15 an example of an air intake kit connected to a built-in induction unit: a. Cut-out opening b. Silicone (pactan) c. Air exhaust opening d. Sleeve with clamp mounted on bottom of unit e. Flex aluminum air duct (...

  • Page 16

    Installation garland rtcsmp induction built-in griddles 16 part # 4532291 rev 2 (01/15/14) 4.6 electrical installation important • refer to the electrical specifications in chapter 3 dimensions and technical specifications and • ensure the supply voltage and the line current match the specifications...

  • Page 17: 5  Function Test

    Function test garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 17 5 function test important caution when the unit is in use, the griddle plate is hot. To avoid burn injuries, do not touch the unit during operation. • before carrying out the function test, the user must unde...

  • Page 18: 6  Operating Instructions

    Operating instructions garland rtcsmp induction built-in griddles 18 part # 4532291 rev 2 (01/15/14) 6 operating instructions important • induction units are more powerful, heat up quicker, and cook food faster than conventional cooking equipment. Your induction unit will require different use and c...

  • Page 19: 6.3  Considerations

    Operating instructions garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 19 6.3 considerations • always season the grill plate before putting any protein on. • cooking food from frozen if frozen food is used directly on the griddle plate regularly, pay special attention that...

  • Page 20: 7  Cleaning

    Cleaning garland rtcsmp induction built-in griddles 20 part # 4532291 rev 2 (01/15/14) 7 cleaning caution ensure no liquid can enter into the induction unit. Do not let water or food overflow the cooking area. Do not use hoses to clean or power wash the induction unit or its vicinity. Caution the cl...

  • Page 21: 8  Maintenance

    Maintenance garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 21 8 maintenance caution maintenance and servicing work other than cleaning as described in this manual must be done by an authorized service personnel. Do not open the induction unit – dangerous electric voltage ...

  • Page 22: 10  Troubleshooting

    Troubleshooting garland rtcsmp induction built-in griddles 22 part # 4532291 rev 2 (01/15/14) 10 troubleshooting do not open the induction unit – dangerous electric voltage inside! The induction unit may only be opened by an authorized service personnel. Caution stop and do not use the induction uni...

  • Page 23

    Troubleshooting garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 23 10.2 problems and possible causes problem possible causes action to take by operator no heat, 7-segment display is off (dark) no power supply. Check the electrical supply, e.G. Power cable plugged into the ...

  • Page 24

    Troubleshooting garland rtcsmp induction built-in griddles 24 part # 4532291 rev 2 (01/15/14) 10.3 troubleshooting with error codes (for service technicians) when a malfunction occurs, an error code (e.G. E03) alternating with the set value is shown on the display. To obtain the internal data and er...

  • Page 25

    Troubleshooting garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) 25 notes:.

  • Page 26

    Troubleshooting garland rtcsmp induction built-in griddles 26 part # 4532291 rev 2 (01/15/14) notes:.

  • Page 27

    Installation and operation manual garland rtcsmp induction built-in griddles part # 4532291 rev 2 (01/15/14) page 27 correct disposal of this product this marking shown on the product indicates that the product should not be disposed as household waste or regular commercial waste. Instead it shall b...

  • Page 28

    Installation & operation manual garland induction built-in griddles with rtcsmp technologies garland commercial ranges ltd. 1177 kamato road, mississauga, ontario, canada l4w 1x4 t. 1-905-624-0260 f. 1-905-624-5669 www.Garland-group.Com usa sales, parts and service 1-800-424-2411 canadian sales 1-88...