Garmin REACTOR 40 COMPACT HYDRAULIC Installation Instructions Manual - page 9
Only One Receiving Wire
If your NMEA 0183 compatible device has only one receiving
wire (Rx), you must connect it to the blue wire (Tx/A) from the
helm control, and leave the white wire (Tx/B) from the helm
control unconnected.
À
NMEA 2000 network (provides power to the helm control)
Á
12 Vdc power source
Helm control
Ã
NMEA 0183 compatible device
Wire Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ê
N/A
Power
Ë
N/A
NMEA 0183 ground
Ì
Blue — Tx/A (+)
Rx
Í
White — unconnected
N/A
Î
Brown — Rx/A (+)
Tx/A (+)
Ï
Green — Rx/B (-)
Tx/B (-)
NOTE:
When connecting a NMEA 0183 device with only one
receiving (Rx) line, you must connect the NMEA 2000 bus and
the NMEA 0183 device to a common ground.
Only One Transmitting Wire
If your NMEA 0183 compatible device has only one transmitting
wire (Tx), it must be connected to the brown wire (Rx/A) from the
helm control, and the green wire (Rx/B) from the helm control
must be connected to NMEA 0183 ground.
À
NMEA 2000 network (provides power to the helm control)
Á
12 Vdc power source
Helm control
Ã
NMEA 0183-compatible device
Wire Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ê
N/A
Power
Ë
Green — Rx/B (-) (connect to
NMEA 0183 ground)
NMEA 0183 ground
Wire Helm Control Wire Color —
Function
NMEA 0183 Compatible
Device Wire Function
Ì
Blue — Tx/A (+)
Rx/A (+)
Í
White — Tx/B (-)
Rx/B (-)
Î
Brown — Rx/A (+)
Tx/A (+)
NOTE:
When connecting a NMEA 0183 device with only one
transmitting (Tx) line, you must connect the NMEA 2000 bus
and the NMEA 0183 device to a common ground.
Specifications
Compact Pump
Specification
Measurement
Dimensions (H × W × D)
84.6 x 100.3 x 155.3 mm (3.3 × 4.0 ×
6.1 in.)
Weight
2.2 kg (5 lb.)
Temperature range
From -15° to 75°C (from 5° to 167°F )
Material
• Motor frame: Powder coat gloss black
• Motor end caps: Cast aluminum ADC12
• Pump body and cap: Anodized die cast
ADC12
• Mounting bracket: 304 stainless steel
ECU cable length
0.6 m (24 in.)
Input voltage
(from
the ECU)
13.8 Vdc max.
Main power usage (from
the ECU)
• Standby: Less than 1 A
• Engaged: From 5 to 10 A
• Peak: 34 A
CCU
Specification
Measurement
Dimensions (L × W × H)
170 × 90 × 50 mm (6.7 × 3.5 × 2 in.)
Weight
200 g (7 oz.)
Temperature range
From -15° to 70°C (from 5° to 158°F)
Material
Fully gasketed, high-impact plastic
Water resistance
IEC 60529 IPX7*
NMEA 2000 input voltage
From 9 to 16 Vdc
NMEA 2000 LEN
4 (200 mA)
*The device withstands incidental exposure to water of up to 1 m for up
to 30 min. For more information, go to
ECU
Specification
Measurement
Dimensions (W × H × D)
168 × 117 × 51 mm (6.6 × 4.6 × 2 in.)
Weight
680 g (24 oz.)
Temperature range
From -15° to 60°C (from 5° to 140°F)
Material
Fully gasketed, high-impact aluminum
alloy
Water resistance
IEC 60529 IPX7*
Power cable length
2.7 m (9 ft.)
Input voltage
From 11.5 to 30 Vdc
Fuse
40 A, blade-type
Main power usage
1 A (not including the pump)
*The device withstands incidental exposure to water of up to 1 m for up
to 30 min. For more information, go to
Alarm
Specification
Measurement
Dimensions (L×diameter)
29
/
32
× 1 in. (23 × 25 mm)
Weight
2.4 oz. (68 g)
Temperature range
From 5°F to 140°F (from -15°C to 60°C)
Cable length
10 ft. (3.0 m)
9