Goldline AsB II Operating And Assembly Manual

Manual is about: ELECTRIC TANKLESS WATER HEATER FOR CENTRAL HEATING SYSTEMS

Summary of AsB II

  • Page 1

    Rok założenia 1992 operating and assembly manual electric tankless water heater for central heating systems (electric water boiler) type ekw - asdc-w - asdc-w - aszn-w - asb ii - asd-w aszn-w asb ii goldline asd-w intelligent antistop system zŁoty certyfikat przedsiĘbiorstwo zŁoty certyfikat grand p...

  • Page 2

    2 bolier ekw asd-w 10 15 8 7 9 2 insulation (polistyren) ch hot water inflow circulation sensor cover ch water outflow tank diagram 460 mm 18 11 spiral coil thermostat sensor cover magnesium anode. Cold water inflow 3/4" l 400 mm 1/2" 325 mm 12 20 c 11:5 3:33 12 0 5 2 01 1 czw c 123 45 6 1/2" 100 mm...

  • Page 3

    3 relays esc on off 10 15 8 7 9 2 18 11 sensors sensors elterm body. Bal. Ch. Huw. Room. Wea.. External regulators attention thermoregulator 0 v! 6 5 4 3 2 1 boiler ekw aszn-w 6 c 11:5 3:33 12 0 5 2 01 1 czw c 123 45 6 boiler equipment 1 2 3 external casing mounting plate automatics mounting bracket...

  • Page 4

    4 thank you for placing trust in our company and for purchasing our product. Operating and assembly manual - electric tankless water heater for central heating systems type ekw aszn-w, asd-w asdc-w, asb ii (electric water boiler) application all of the goldline (ekw aszn-w, ekw asd-w, ekw asdc-w, ek...

  • Page 5

    Hydraulic and electric assembly hydraulic assembly please familiarize yourself with the electrical and hydraulic diagram, as well as technical data prior to assembly. Details on www.Elterm.Pl boilers ekw aszn-w, asd-w, asb ii are hanging vertical devices and should be hung on bolts. First, remove th...

  • Page 6: Boiler Start-Up

    6 electric assembly boiler start-up connection to the electrical system needs to be done in accordance with the regulations applicable in the country where the given boiler is installed, and therefore must be done by qualified electrician (electrical company installing the boiler puts a relevant sta...

  • Page 7: Boiler Start-Up

    Boiler start-up elements 1 –lcd screen 2 – huw signal icon 3 – huw pump active icon 4 – huw program active icon 5 – ch signal icon 6 – ch pump active icon 7 – ch program active icon 8 – current huw temperature 9 – current ch temperature 10 – time 11 – data 12 – ch and huw temperature setting icon 13...

  • Page 8: Settings

    8 3 settings settings attention!!!! Boiler connected to the installation according to point ii electrical assembly. Ch (huw) pump should be turned on for iii speed. Valves on radiators should be completely open while start-up. 1. Red diode on – no. 20, boiler stand-by – boiler turned on. 2. For 5 s....

  • Page 9: Setting

    Setting - press another time, below sign appears: huw ch - decrease ch or huw temp. - increase ch or huw temp. - „back” (given parameters are set) multiple press enables getting back to main menu 9 huw 50°c 50°c default: 50 ch 2 „weather curve” setting - press 1 time, enter the „weather curve” setti...

  • Page 10: Settings

    10 3. Room temperature setting on boiler (optional) - press 1 time, enter the function: room temperature setting on boiler - decrease ch or huw temp. (from 5° to 29°c) - increase ch or huw temp. (from 6° to 30°c) - „back” (given temperatures are set) multiple press enables getting back to main menu ...

  • Page 11: Setting

    Setting ad. A2 11 settings energy consum. Venting ad. A2. „settings – sections ” active ch and huw. - press 1 time, setting sign appears - press 2 times, sections sign appears - (to enter section area press one time button: another press shows below screen: huw ch on on ) huw ch on on - press 1 time...

  • Page 12: Settings

    12 ad. A4. „settings – pid-p” – proportional integral derivative controller - press 1 time, settings sign appears - press 2 times, pid-p sign appears ( to enter press three times button on the right - change parameter - change parameter’s value attention: in case boiler needs long time to achieve se...

  • Page 13: Settings

    Settings ad. A6 13 settings energy consum. Venting ad. A6. „settings – huw histerese” - press 1 time, settings sign appears - press 2 times, huw histerese sign appears ( to enter press five times button on the right) - press another time, below screen is visible huw histerese - decrease histerese 1 ...

  • Page 14: Settings

    14 settings weekly programming on boiler + huw time programming (optional) - are not a standard boiler equipment weekly programming on boiler, as well as huw time programming enables setting and maintaining given temperature at any defined time periods with minute accuracy. Limpid menu and illuminat...

  • Page 15: Settings

    Settings ad. A8 15 settings energy consum. Venting ad. A8. „settings –programs room” (optional) - press 1 time, settings sign appears - press 2 time, programs room sign appears ( to enter press seven times button on the right) - press another time, settings menu is visible - change parameter - chang...

  • Page 16: Settings

    16 active / nonactive program each program can be temporarily deactivated. One should then turn in programs room or programs huw: active: no in case we want to turn the program on: active: yes settings tu we start: stop: temp: active: tu we start: stop: temp: active : th fr sa su 08:03 1 6 :00 nr 25...

  • Page 17: Settings

    Settings - press 1 time, below screen appears: huw ch (turn on huw bleeding) 17 on on huw ch off off - press 1 time – go to huw function: off - press 1 time – turn on huw bleeding: on same method applies to ch installation - after proper venting process, one should turn function off: huw ch off off ...

  • Page 18: Declaration Of Conformity

    Declaration of conformity declaration of conformity ec no. 1/2011 elterm m.M. Kaszuba sp.J. 86-200 cheŁmno ul. PrzemysŁowa 5 we herewith declare, under our sole responsibility, that the following products: tankless water heater for central heating systems (electric central heating water boiler) type...

  • Page 19: We Also Recommend:

    We also recommend: hydraulic balancers she, she-sp, she-oc from 25 to 420 kw leatherette coat pur foam 0,025w/mk hydraulic balancers she-elterm hydraulic balancers she-sp elterm with air separator hydraulic balancers she-oc elterm insulated pump modules with mix system boiler's pump module with mix ...

  • Page 20

    Reccomended room temperature controllers: thermline rt room temperature controllers thermline rt pump temperature controllers thermline pt thermline rt–r (air temp.) thermline rt–f (floor temp.) thermline rt–rf (air-floor temp.) thermline rt–rw (wireless air temp.) thermline pt-p2 thermline pt-p3 th...