Golmar 50124545 Instruction Manual

Manual is about: Video Kit digital installation

Summary of 50124545

  • Page 1

    Stadio plus video kit digital installation instructions manual 67 une façon simple de vérifier si les équipements fonctionnent correctement, est de les déconnecter de l'installation et de les tester directement sur le circuit microprocesseur el500se. Un court-circuit entre les différentes bornes (ou...

  • Page 2

    70 o o o o o o o o microprocessed system with 3 common wires plus coaxial cable installation or 4 common wires plus twisted pair (only for kits /sc). Fully compatible with 'stadio' audio systems of 4 common wires installation. Unlimited number of door panels being not necessary the use of switching ...

  • Page 3

    70 o o o o o o o o microprocessed system with 3 common wires plus coaxial cable installation or 4 common wires plus twisted pair (only for kits /sc). Fully compatible with 'stadio' audio systems of 4 common wires installation. Unlimited number of door panels being not necessary the use of switching ...

  • Page 4

    Door panel installation 1650 1850 1450 mbedding box positioning. E break the bottom flange to pass the cables through. Reparing the embedding box. P o to make a call the visitor should press the push button corresponding to the apartment he wishes to contact. An acoustic tone will be heard confirmin...

  • Page 5

    Door panel installation 1650 1850 1450 mbedding box positioning. E break the bottom flange to pass the cables through. Reparing the embedding box. P o to make a call the visitor should press the push button corresponding to the apartment he wishes to contact. An acoustic tone will be heard confirmin...

  • Page 6

    Door panel installation door panel installation ssembling the el500se microprocessed circuit. A 1 2 old the door panel on the embedding box. H 74 73 the el500se circuit is to be assembled on the top of the embedding box. Insert the circuit in the top flanges of the embedding box (1). Push-in the cir...

  • Page 7

    Door panel installation door panel installation ssembling the el500se microprocessed circuit. A 1 2 old the door panel on the embedding box. H 74 73 the el500se circuit is to be assembled on the top of the embedding box. Insert the circuit in the top flanges of the embedding box (1). Push-in the cir...

  • Page 8

    Door panel installation door panel installation 76 75 escription of the sw1 configuration dip-switch of d the el500se microprocessor module. Placed to off if the el500se microprocessor module is configured as el500 . Set to on if the el500se microprocessor module is configured as el501 (only general...

  • Page 9

    Door panel installation door panel installation 76 75 escription of the sw1 configuration dip-switch of d the el500se microprocessor module. Placed to off if the el500se microprocessor module is configured as el500 . Set to on if the el500se microprocessor module is configured as el501 (only general...

  • Page 10

    78 power supply installation lock release installation nstalling the fa-805 power supply. I din 46277 77 door panel installation lace the nameplate labels. P open the label holder. Place the label and close. Lose the door panel. C inal adjustments. F if after starting the system it's considered that...

  • Page 11

    78 power supply installation lock release installation nstalling the fa-805 power supply. I din 46277 77 door panel installation lace the nameplate labels. P open the label holder. Place the label and close. Lose the door panel. C inal adjustments. F if after starting the system it's considered that...

  • Page 12

    80 monitor description 79 monitor description a. B. C. D. E. F . G. H. I . J . K. L . M. Handset. B/w or color screen (depending on the model). Led to indicate the monitor is on. Function push buttons. Cord. Attachment holes. Identification label. Connecting points. Cn4 connector. Three positions ca...

  • Page 13

    80 monitor description 79 monitor description a. B. C. D. E. F . G. H. I . J . K. L . M. Handset. B/w or color screen (depending on the model). Led to indicate the monitor is on. Function push buttons. Cord. Attachment holes. Identification label. Connecting points. Cn4 connector. Three positions ca...

  • Page 14

    82 terminals +, – and malla (shield) are duplicated for easiest cascade installation of parallel monitors or telephones. If the first monitor is not placed on the connector, cascade units will not be powered. Escription of the rctk-plus d monitor connector. A. Wall attachment hole (x6). B. Monitor a...

  • Page 15

    82 terminals +, – and malla (shield) are duplicated for easiest cascade installation of parallel monitors or telephones. If the first monitor is not placed on the connector, cascade units will not be powered. Escription of the rctk-plus d monitor connector. A. Wall attachment hole (x6). B. Monitor a...

  • Page 16

    84 monitors programming 83 monitor installation ix the monitor connector to the wall. F ix the monitor. F rogramming the tekna plus monitors. P set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the terminal connector protection cove...

  • Page 17

    84 monitors programming 83 monitor installation ix the monitor connector to the wall. F ix the monitor. F rogramming the tekna plus monitors. P set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the terminal connector protection cove...

  • Page 18

    Telephone description 86 telephone description 85 escription of the t-940 plus telephone. D a. B. C. D. E. F. G. H. I. Telephone handset. Speaker grille. Microphone hole. Subjection hole. Telephone cord connectors. Function push buttons. On-off light indicator. Call reception volume control. Hook sw...

  • Page 19

    Telephone description 86 telephone description 85 escription of the t-940 plus telephone. D a. B. C. D. E. F. G. H. I. Telephone handset. Speaker grille. Microphone hole. Subjection hole. Telephone cord connectors. Function push buttons. On-off light indicator. Call reception volume control. Hook sw...

  • Page 20

    88 87 telephones programming rogramming the t-940 plus telephones. P switch off the telephone to be programmed. Once the telephone is off, press the door release push button. Set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the ter...

  • Page 21

    88 87 telephones programming rogramming the t-940 plus telephones. P switch off the telephone to be programmed. Once the telephone is off, press the door release push button. Set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the ter...

  • Page 22

    90 89 . F unction push buttons telephone description ix the telephone to the wall f . It is necessary to open the telephone for wiring and fixing purposes to open the telephone, insert a plain screwdriver into the slots and gently lever as shown in the drawing . . P . C . . Ass the installation wire...

  • Page 23

    90 89 . F unction push buttons telephone description ix the telephone to the wall f . It is necessary to open the telephone for wiring and fixing purposes to open the telephone, insert a plain screwdriver into the slots and gently lever as shown in the drawing . . P . C . . Ass the installation wire...

  • Page 24

    92 91 installation diagrams onnexion of an a.C. Lock release. C rogramming the t-740 plus telephones. P to show that the system is ready for programming, the door panel and the telephone's handset will reproduce a tone (the telephone led will light). Audio communication can be established. Press the...

  • Page 25

    92 91 installation diagrams onnexion of an a.C. Lock release. C rogramming the t-740 plus telephones. P to show that the system is ready for programming, the door panel and the telephone's handset will reproduce a tone (the telephone led will light). Audio communication can be established. Press the...

  • Page 26

    94 installation diagrams main ne or several accesses with o coaxial cable. 93 cascade installation example. Remove the jumper from the cn4 connector in all the monitors (see page 81), except on the one where the video cable finishes (don't uses the video output). Distributed installation example. Re...

  • Page 27

    94 installation diagrams main ne or several accesses with o coaxial cable. 93 cascade installation example. Remove the jumper from the cn4 connector in all the monitors (see page 81), except on the one where the video cable finishes (don't uses the video output). Distributed installation example. Re...

  • Page 28

    96 installation diagrams main ne or several accesses with o twisted pair. 95 cascade installation example. Remove jp1 jumper from all of the el562 monitor modules (see page 81), except on the one where the twisted pair cable finishes (don't uses the video output). Remove jp1 jumper from all of the v...

  • Page 29

    96 installation diagrams main ne or several accesses with o twisted pair. 95 cascade installation example. Remove jp1 jumper from all of the el562 monitor modules (see page 81), except on the one where the twisted pair cable finishes (don't uses the video output). Remove jp1 jumper from all of the v...

  • Page 30

    98 optional connections 97 optional connections xternal lock release activation. E uxiliary devices activation with a tekna plus monitor. The use of a fa-805 power supply ( tf-104 transformer (maximum current 1,5a) will be necessary to activate a second lock release. Maximum current 0,8a) or onnecti...

  • Page 31

    98 optional connections 97 optional connections xternal lock release activation. E uxiliary devices activation with a tekna plus monitor. The use of a fa-805 power supply ( tf-104 transformer (maximum current 1,5a) will be necessary to activate a second lock release. Maximum current 0,8a) or onnecti...

  • Page 32

    100 optional connections 99 optional connections ntercom function. I oor bell push button connection. D xternal lock release activation with e t-740plus telephone. A + _ d t-740 plus sar-12/24 p n 220 vac/ 1.8a max. In in nc na c ( ) * the neutral supply from the stairs light will be wired through t...

  • Page 33

    100 optional connections 99 optional connections ntercom function. I oor bell push button connection. D xternal lock release activation with e t-740plus telephone. A + _ d t-740 plus sar-12/24 p n 220 vac/ 1.8a max. In in nc na c ( ) * the neutral supply from the stairs light will be wired through t...

  • Page 34

    102 101 troubleshooting hints an easy way to check that the system is working properly is to disconnect the wiring from the door panel and to check the monitor directly connected to the el500se circuit. No shortcircuit will damage the connected units, with the exception of a shortcircuit between cto...

  • Page 35

    102 101 troubleshooting hints an easy way to check that the system is working properly is to disconnect the wiring from the door panel and to check the monitor directly connected to the el500se circuit. No shortcircuit will damage the connected units, with the exception of a shortcircuit between cto...

  • Page 36

    Golmar se reserva el derecho a cualquier modificación sin previo aviso. Golmar se réserve le droit de toute modification sans préavis. Golmar reserves the right to make any modifications without prior notice. Golmar@golmar.Es www.Golmar.Es 103 este producto es conforme con las disposiciones de las d...