Golmar Stadio Plus 4502/AL Instruction Manual - page 5
LOCK RELEASE INSTALLATION
7
6
4Plus operation mode.
C
Use this operation mode to connect the module to a C4Plus access control system.
In this case, the C4Plus relays will be activated instead of the module internal relay.
Use the PIN code to enter into programming mode, as it's described on page 4.
In case of valid code, the display will show the selected
operation mode (C4P). In case of wrong code,
the display will show the message "E–5" during
10 seconds and will automatically exit from the
programming mode.
M 4 x 8
f3,5 x 25
DIN-7972
DIN-963
IMPORTANT: a varistor and a diode are supplied with this proximity reader.
In case to connect an a.c. lock release, place the varistor
on the lock release terminals directly.
In case to connect an d.c. lock release, place the diode
on the lock release terminals directly. Special attention
on polarity is required.
+
-
a.c. lock release
d.c. lock release
1N4007
MODULE PROGRAMMING
In this mode, the cards are recorded on the C4Plus memory instead of the memory module.
DIRECTORPlus software will be necessary to manage the C4Plus memory. However, one
of the C4Plus relays must be assigned to the proximity reader module.
Use "UP" or "DOWN" arrows to select a C4Plus relay.
The display will show the following messages:
C–1 (relay 1), C–2 (relay 2), C–3 (relay 3) or
C–4 (relay 4).
To exit from the programming mode, wait 20 sec.
from the last operation.
If the lock release will be installed in a metal door, use a
Ø3,5mm. drill and tap the hole. In case of wood door,
use a
Ø3mm. drill.
ock release installation.
L