Golmar Stadio Plus T500SE ML Instruction Manual

Manual is about: Audio and Video door entry system

Summary of Stadio Plus T500SE ML

  • Page 1

    99 rÉsolution des problÈmes stadio plus instructions manual audio and video door entry system digital installation (one or several accesses doors / general door panel) une façon simple de vérifier si les équipements fonctionnent correctement, est de les déconnecter de l'installation et de les tester...

  • Page 2

    102 101 safety precautions introduction starting recommendations index first of all we would like to thank and congratulate you for the purchase of this product manufactured by golmar. The commitment to reach the satisfaction of our customers is stated through the iso-9001 certification and for the ...

  • Page 3

    System operation o to make a call the visitor should press the push button corresponding to the apartment he wishes to contact. An acoustic tone will be heard confirming the call is in progress once the push button has been pressed. At this moment the call will be received at the monitor (telephone)...

  • Page 4

    Modules model w h d 106 105 door panel installation mbedding box positioning. E 1650 1850 1450 reparing the cables entry. P break the bottom flange to pass the cables through. In case of door panels with more than one embedding box, break the side flanges and attach the embedding boxes using uc junc...

  • Page 5

    108 107 door panel installation door panel installation 1 2 ssembly the sound module. A ssembling the el500se microprocessed circuit and the el516se push buttons encoders. A old the door panel on the embedding box. H lace the label (informative window). P before connecting the circuit of the informa...

  • Page 6

    110 109 ush buttons wiring. P door panel installation door panel installation lace the nameplate labels. P open the label holder. Place the label and close. Plug the push buttons connection cable to the cn6 connector of the el500se microprocessor circuit, this cable has 10 conductors (p1 to p8, b an...

  • Page 7

    112 111 ush buttons limit. P ush buttons digital code. P the maximum number of push buttons to be connected depends on the number of installed el516se encoders, as it is shown on the following chart: without el516se circuit: with 1 el516se circuit: with 2 el516se circuits: with 3 el516se circuits: w...

  • Page 8

    114 113 door panel installation general door panel installation inary coding of the sw2 configuration dip switch b of the el500se microprocessor module. The switches set to off have null value. The values of the switches set to on are shown in the enclosed chart. The backbone code will be calculated...

  • Page 9

    General door panel installation define a backbone code to program with dip switches sw2-4 to sw2- 10. Set a code between 1 and 120. To set the code use binary coding, (see page 113). Press the general door panel push button that is wished has this backbone code. At this moment the general door panel...

  • Page 10

    118 117 amps wiring. L door panel installation lock release installation nstalling the fa-plus and fa-plus/c power supplies. I din 46277 f3,5 x 25 din-7971 f3,5 x 25 din-7971 m 4 x 8 f3,5 x 25 din-7972 din-963 power supply installation ock release installation. L inal adjustments. F lose the door pa...

  • Page 11

    120 119 j l k m a. B. C. D. E. F . G. H. I . J . K. L . M. Handset. B/w or color screen (depending on the model). Front film. Function push buttons. Cord. Attachment holes. Identification label. Connecting points. Cn4 connector. Three positions call reception volume control. Cable slot. Contrast con...

  • Page 12

    122 121 v in v out malla shield malla shield a hz- int sa cto 2c a1 vp mp d ref rcpl-plus lote code 11758882 colocar la parte superior de la regleta a 1,60m. Del suelo. Place the top part of the monitor connector at 1,60m. From the floor. 50mm. 50mm. Presionar para abrir. Press to open. Escription o...

  • Page 13

    124 123 monitor installation monitors programming ix the monitor connector to the wall. F ix the monitor. F rogramming the platea plus monitors. P set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the terminal connector protection c...

  • Page 14

    126 125 telephone description telephone description escription of the t-940 plus telephone. D a. B. C. D. E. F. G. H. I. Telephone handset. Speaker grille. Microphone hole. Subjection hole. Telephone cord connectors. Function push buttons. On-off light indicator. Call reception volume control. Hook ...

  • Page 15

    127 telephones programming rogramming the t-940 plus telephones. P switch off the telephone to be programmed. Once the telephone is off, press the door release push button. Set to on the switch number 2 of the sw2 configuration dip switch, that's accessible in the el500se module by opening the termi...

  • Page 16

    . F unction push buttons 129 telephone description ix the telephone to the wall f . It is necessary to open the telephone for wiring and fixing purposes to open the telephone, insert a plain screwdriver into the slots and gently lever as shown in the drawing . . P . C . . Ass the installation wires ...

  • Page 17

    132 installation diagrams onnexion of an a.C. Lock release. C ink of several power supplies units. L 1st fa-plus 2nd fa-plus/c or fa-plus sec pri ~ ~ main + + - - sec pri ~ ~ main + + - - rogramación de los teléfonos t-740 plus. P p3 to show that the system is ready for programming, the door panel a...

  • Page 18

    134 133 main main place this power supply as closest as possible to the first distributor. One or several accesses doors ideo installation with coaxial cable. V 1,00mm² 2,50mm² 0,25mm² 0,25mm² rg-59 rg-59 terminal sections chart 50m. Distance 150m. A , a , a, d in out v , v , v , v in+ out+ in out +...

  • Page 19

    136 135 main main * take off jp1 jumper of all the distributors except in the last one. 1,00mm² 2,50mm² 0,25mm² 0,25mm² cat-5 cat-5 terminal sections chart 50m. Distance 150m. A , a , a, d in out v , v , v , m in+,- out+,- p,d p,d +, –, cv1, cv2 ideo installation without coaxial cable. V fa-plus/c o...

  • Page 20

    138 137 main main udio installation. A 1,00mm² 2,50mm² 0,25mm² 0,25mm² terminal sections chart 50m. Distance 150m. A , a , a, d in out +, –, cv1, cv2 *place this power supply as closest as possible to the first telephone. Fa-plus/c o fa-plus a a + + _ _ d d t-740 plus t-740 plus a + _ d t-940 plus a...

  • Page 21

    Sw1 d malla v in- a in a out v in+ v out- v out+ cn2 + ap - - + cv1 cv2 - +12 - sw2 to monitors continues in the following p a ge e s + s1 sec pri ~ ~ + + - - sw2 d4l-plus jp1 fa-plus o fa-plus/c main el501 mode to monitors e s + s1 fa-plus o fa-plus/c sec pri ~ ~ + + - - d4l-plus jp1 main inner doo...

  • Page 22

    142 141 general door panel installation diagrams ideo installation with general door panel to large residential complexes. V for greater distances contact our technical support department. 1,50mm² 2,50mm² 0,25mm² 0,25mm² cat-5 rg-59 terminal sections chart 100m. Distance 300m. A , a , a, d in out v ...

  • Page 23

    To telephones to telephones udio installation with general door panel to large residential complexes. A 1,50mm² 2,50mm² 0,25mm² 0,25mm² terminal sections chart 100m. Distance 300m. A , a , a, d in out for greater distances contact our technical support department. +, –, cv1, cv2 sec pri ~ ~ + + - - ...

  • Page 24

    146 145 optional connections optional connections xternal lock release activation. E uxiliary devices activation. A the use of a tf-104 transformer will be necessary to activate a second lock release. Onnecting the platea plus monitor c to a video recorder or tv. A _ + d malla v in v out cn4 platea ...

  • Page 25

    Ntercom function. I 148 147 optional connections optional connections oor bell push button connection. D xternal lock release activation with t-740plus telephone. E a + _ d t-740 plus sar-12/24 p n 220 vac/ 1.8a max. In in nc na c ( ) * the neutral supply from the stairs light will be wired through ...

  • Page 26

    150 149 notas/notes an easy way to check that the system is working properly is to disconnect the wiring from the door panel and to check the monitor directly connected to the el500se circuit. No shortcircuit will damage the connected units, with the exception of a shortcircuit between cto and ' ' m...