Golmar T505i Stadio Plus Instruction Manual

Manual is about: Audio door entry system for residential complexes 4+'n' installation

Summary of T505i Stadio Plus

  • Page 1

    T505i rev.0103 stadio plus instructions manual (+34) 934 800 696 (+34) 609 807 631 golmar@golmar.Es golmar reserves the right to make any modifications without prior notice for improvement purposes. Audio door entry system for residential complexes 4+'n' installation.

  • Page 2

    1 introductiÓn important notice system characteristics o o o this instruction manual describes the assembly and wiring of audio door entry systems with 4+n wires installation for residential complexes: several internal buildigns and one or several general entrance door panels. Do not use the instruc...

  • Page 3

    3 door panel installation door panels description eneral entrance door panel g description. Note: each el505 microprocessed circuit can manage two internal door panels. Use as many circuits as required. The 3xx1 push buttons modules have a window useful to show the name of the internal building and ...

  • Page 4

    5 4 door panel installation lace the embedding p box. Pass the wiring through the hole made in the bottom part of the embedding box. Level and flush the embedding box. Once the embedding box is placed, remove the protective labels from the attaching door panel holes. Ssembly the door panel a modules...

  • Page 5

    Lacing the identifying label p of the 3xx1 window 7 6 ssembly and wiring of the el505 microprocessed a circuits in the general entrance door panel(s). These circuits are to be assembled on the top of the embedding box. Insert the circuit in the top flanges of the embedding box (1). Push-in the circu...

  • Page 6

    8 9 lace the nameplate labels. P open the label holder. Place the label and close. Inal f adjustments. If after starting the system it's considered that the audio volume isn't correct, proceed with the necessary adjustments as shown. Once the nameplate labels are placed, wire the lamps from differen...

  • Page 7

    10 system operation 11 a d c e e g f b o o to make a call the visitor should press the push button corresponding to the apartment he wishes to contact. An acoustic tone will be heard confirming the call as the push button is pressed. At this moment the call will be received at the telephone in the d...

  • Page 8

    Installation diagram 13 installation diagram 12 ind. 1a ind. 2a 0 0 10 10 5 5 3 3 p1 p1 cv cv inh co cp ind. 1a ind. 2a ind. 3a p cn1 - tf-104 el-551 jp1 jp1 building a sec ~ ~ pri ~ ~ main ind. 1a ind. 2a ind. 3a ind. 1b ind. 2b 0 0 10 10 5 5 3 3 p1 p1 cv cv inh co cp ind. 1b ind. 2b ind. 3b p cn1 ...

  • Page 9

    Optional connections 14 sections chart 15 ind. 0 0 10 10 5 5 3 3 p1 p1 xternal lock release activation. E ections chart. S inking 3xx1 modules. L a1 b1 a2 b2 l1 l2 1 1 l1 2 2 l2 l1 l2 el505 a window b window el551 if the general entrance door panel contains 3xx1 window modules to show the busy statu...

  • Page 10

    Troubleshooting hints 16 o nothing operates. W check the output transformer voltage between sec terminals: it should have 12 to 17va.C. If not, disconnect the transformer from the installation and measure again. If it's correct now, it means there is a short circuit in the installation: disconnect t...