Standard Features
• R-410A chlorine-free refrigerant
• TuffTube™ tubular heat exchanger
• High-efficiency scroll compressor
• HIgh- and low-pressure switches
• Copper tube / aluminum fin coils
• Contactor with lugs
• High-capacity, steel-cased filter drier
• 24-volt terminal strip
• Convertible
• Easy to service
• Built-in filter rack with standard 2” filters
• Bottom utility entry
• Complies with California NOx emissions standards
• AHRI Certified; ETL Listed
Cabinet Features
• Heavy-gauge, galvanized-steel cabinet with
UV-resistant powder-paint finish
• Full Perimeter Rail
CPG C
ommerCial
3-
to
6-t
on
P
aCkaGed
G
as
/e
leCtriC
U
nits
13 seer /
UP
to
11.3 eer
80% aFUe
* Complete warranty details available from your local dealer or at www.goodmanmfg.com.
Contents
Nomenclature ....................................................................2
Product Specifications .......................................................3
Airflow Data .....................................................................10
Expanded Cooling Data ...................................................17
Dimensions ......................................................................25
Wiring Diagrams .............................................................29
Accessories .......................................................................39
C
oolinG
C
aPaCity
:
34,600 — 71,000 BtU/
h
h
eatinG
C
aPaCity
:
36,800 — 110,400 BtU/
h
Summary of CPG0360451D***B Series
Page 1
Ss-cpg36-72 www.Goodmanmfg.Com 3/12 supersedes 11/11 standard features • r-410a chlorine-free refrigerant • tufftube™ tubular heat exchanger • high-efficiency scroll compressor • high- and low-pressure switches • copper tube / aluminum fin coils • contactor with lugs • high-capacity, steel-cased fil...
Page 2
P roduct s pecifications p roduct s pecifications 2 www.Goodmanmfg.Com ss-cpg36-72 n omenclature c p g 060 045 3 b * * * a * 1 2 3 4,5,6 7,8,9 10 11 12 13 14 15 16 revision levels major & minor brand factory-‐installed op7ons c commercial x no opcons a non-‐powered convenience outlet configura7on b...
Page 3: — Cpg036
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 3 p roduct s pecifications — cpg036 cpg036 0451d***b* cpg036 0453d***b* cpg036 0453b***b* cpg036 0454b***b* cooling capacity total btu/h 34,600 34,600 34,600 34,600 sensible btu/h 25,600 25,600 25,600 25,600 seer / eer ...
Page 4: — Cpg036 (
P roduct s pecifications p roduct s pecifications 4 www.Goodmanmfg.Com ss-cpg36-72 p roduct s pecifications — cpg036 ( cont .) cpg036 0901d***b* cpg036 0903d***b* cpg036 0903b***b* cpg036 0904b***b* cpg036 0907b***b* cooling capacity total btu/h 34,600 34,600 34,600 34,600 34,600 sensible btu/h 25,6...
Page 5: — Cpg048
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 5 p roduct s pecifications — cpg048 cpg048 0901d***b* cpg048 0903d***b* cpg048 0903b***b* cpg048 0904b***b* cooling capacity total btu/h 45,500 45,500 45,500 45,500 sensible btu/h 35,000 35,000 35,000 35,000 seer / eer ...
Page 6: — Cpg048 (
P roduct s pecifications p roduct s pecifications 6 www.Goodmanmfg.Com ss-cpg36-72 p roduct s pecifications — cpg048 ( cont .) cpg048 1151d***b* cpg048 1153d***b* cpg048 1153b***b* cpg048 1154b***b* cpg048 1157b***b* cooling capacity total btu/h 45,500 45,500 45,500 45,500 45,500 sensible btu/h 35,0...
Page 7: — Cpg060
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 7 p roduct s pecifications — cpg060 cpg060 0901d***b* cpg060 0903d***b* cpg060 0903b***b* cpg060 0904b***b* cooling capacity total btu/h 59,500 59,500 59,500 59,500 sensible btu/h 43,200 43,200 43,200 43,200 seer / eer ...
Page 8: — Cpg060 (
P roduct s pecifications p roduct s pecifications 8 www.Goodmanmfg.Com ss-cpg36-72 p roduct s pecifications — cpg060 ( cont .) cpg060 1401d***b* cpg060 1403d***b* cpg060 1403b***b* cpg060 1404b***b* cpg060 1407b***b* cooling capacity total btu/h 59,500 59,500 59,500 59,500 59,500 sensible btu/h 43,2...
Page 9: — Cpg072
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 9 p roduct s pecifications — cpg072 cpg072 1403b***b* cpg072 1404b***b* cpg072 1407b***b* cooling capacity total btu/h 71,000 71,000 71,000 sensible btu/h 48,280 48,280 48,280 eer / ieer 11.1 / 11.2 11.1 / 11.2 11.1 / 1...
Page 10: — Cpg036B
P roduct s pecifications p roduct s pecifications 10 www.Goodmanmfg.Com ss-cpg36-72 a irflow d ata — cpg036b s tandard d irect d rive — h orizontal s tandard d irect d rive — d own s hot cfm static amps watts rpm speed tap cfm static amps watts rpm speed tap 1293 0.1 1.72 364 715 low 1313 0.10 1.68 ...
Page 11: — Cpg036B (
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 11 a irflow d ata — cpg036b ( cont .) s tandard b elt d rive — h orizontal esp (“ h 2 o) turns open 0 1 2 3 4 5 cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp 0.2 --- --- --- --- --- --- --- --- 1524 0.32 1340 0.25 0.4...
Page 12: — Cpg048B
P roduct s pecifications p roduct s pecifications 12 www.Goodmanmfg.Com ss-cpg36-72 a irflow d ata — cpg048b s tandard d irect d rive — h orizontal s tandard d irect d rive — d own s hot cfm static amps watts rpm speed tap cfm static amps watts rpm speed tap 1592 0.1 2.54 543 815 low 1612 0.1 2.60 5...
Page 13: — Cpg048B (
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 13 a irflow d ata — cpg048b ( cont .) s tandard b elt d rive — h orizontal esp (“ h 2 o) turns open 0 1 2 3 4 5 cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp 0.2 --- --- --- --- --- --- --- --- 1800 0.47 1556 0.35 0.4...
Page 14: — Cpg060B
P roduct s pecifications p roduct s pecifications 14 www.Goodmanmfg.Com ss-cpg36-72 a irflow d ata — cpg060b s tandard d irect -d rive — h orizontal s tandard d irect -d rive — d own s hot cfm static amps watts rpm speed tap cfm static amps watts rpm speed tap 1416 0.1 1.63 176 588 t1 1237 0.1 1.64 ...
Page 15: — Cpg060B (
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 15 a irflow d ata — cpg060b ( cont .) s tandard b elt d rive — h orizontal esp (“ h 2 o) turns open 0 1 2 3 4 5 cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp 0.2 --- --- --- --- 2460 0.96 2251 0.80 2073 0.65 1862 0.51...
Page 16: — Cpg072B
P roduct s pecifications p roduct s pecifications 16 www.Goodmanmfg.Com ss-cpg36-72 a irflow d ata — cpg072b s tandard b elt d rive — h orizontal esp (in w.C.) 0 turns 1 turn 2 turns 3 turns 4 turns 5 turns cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp cfm bhp 0.2 --- --- --- --- --- --- 2749 1.18 2573 0....
Page 17: — Cpg036B
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 17 e xpanded c ooling d ata — cpg036b outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 13...
Page 18: — Cpg036B (
P roduct s pecifications p roduct s pecifications 18 www.Goodmanmfg.Com ss-cpg36-72 e xpanded c ooling d ata — cpg036b ( cont .) outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6...
Page 19: — Cpg048B
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 19 e xpanded c ooling d ata — cpg048b outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 18...
Page 20: — Cpg048B (
P roduct s pecifications p roduct s pecifications 20 www.Goodmanmfg.Com ss-cpg36-72 e xpanded c ooling d ata — cpg048b ( cont .) outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6...
Page 21: — Cpg060B
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 21 e xpanded c ooling d ata — cpg060b outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 22...
Page 22: — Cpg060B (
P roduct s pecifications p roduct s pecifications 22 www.Goodmanmfg.Com ss-cpg36-72 e xpanded c ooling d ata — cpg060b ( cont .) outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6...
Page 23: — Cpg072B
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 23 e xpanded c ooling d ata — cpg072b outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70 24...
Page 24: — Cpg072B (
P roduct s pecifications p roduct s pecifications 24 www.Goodmanmfg.Com ss-cpg36-72 e xpanded c ooling d ata — cpg072b ( cont .) outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 6...
Page 25: Appendix C Unit Dimensions
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 25 d imensions 30 appendix c unit dimensions horizontasl discharge vertical discharge note for horizontal discharge, remove the supply and return duct covers and place them over the vertical discharge return and supply ...
Page 26
P roduct s pecifications p roduct s pecifications 26 www.Goodmanmfg.Com ss-cpg36-72 u nit c learances maintain an adequate clearance around the unit for safety, service, maintenance, and proper unit operation. Leave a total clearance of 75” on the main control panel side of the unit for possible rem...
Page 27: — R
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 27 r oof c urb i nstallation — r igging provisions for forks have been included in the unit base frame. No other fork locations are approved. • unit must be lifted by the four lifting holes located at the base frame cor...
Page 28
P roduct s pecifications p roduct s pecifications 28 www.Goodmanmfg.Com ss-cpg36-72 r oof c urb i nstallation ( cont .) curb installations must comply with local codes and should follow the established guidelines of the national roofing contractors association. Proper unit installation requires that...
Page 29: —
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 29 w iring d iagram — cpg0360451d (s ingle -p hase , d irect d rive ) 2. For 208 volt transformer operation move black wire from terminal 3 to terminal 2 on transformer. 1. Replacement wire must be the same size and typ...
Page 30: —
P roduct s pecifications p roduct s pecifications 30 www.Goodmanmfg.Com ss-cpg36-72 w iring d iagram — cpg036/480901d (s ingle -p hase d irect d rive ) 2. For 208 volt transformer operation move black wire from terminal 3 to terminal 2 on transformer. 1. Replacement wire must be the same size and ty...
Page 31: —
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 31 w iring d iagram — cpg060*1d (s ingle -p hase d irect d rive ) auxillary limit switch female plug/connector integrated ignition control vmr ls 4 installer/serviceman troubleshooting this appliance. Status light codes...
Page 32: —
P roduct s pecifications p roduct s pecifications 32 www.Goodmanmfg.Com ss-cpg36-72 w iring d iagram — cpg060*3d (t hree -p hase , d irect d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arnin g high voltage: disconnect al...
Page 33: —
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 33 w iring d iagram — cpg036.48*3d (t hree -p hase d irect d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arnin g high voltage: disconnect a...
Page 34: —
P roduct s pecifications p roduct s pecifications 34 www.Goodmanmfg.Com ss-cpg36-72 w iring d iagram — cpg036/48*3d (t hree -p hase , d irect d rive ) wiring is subject t o chang e. Alw ay s re fer to the wiring diagr am or the unit for the mos t up-t o-da te wiring. ⚠ w arning high volt ag e: disc ...
Page 35: , B
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 35 w iring d iagram — cpg036-600904b/7b — cpg036*4b/7b — cpg072*4b/7b (460v/575 v , b elt d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arn...
Page 36: —
P roduct s pecifications p roduct s pecifications 36 www.Goodmanmfg.Com ss-cpg36-72 w iring d iagram — cpg036/48/600903b — cpg072*3b (t hree -p hase , b elt d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arnin g high volt...
Page 37: —
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 37 w iring d iagram — cpg036/480454b — cpg072*4b/7b (460v/ 575v b elt d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arnin g high voltage: d...
Page 38: —
P roduct s pecifications p roduct s pecifications 38 www.Goodmanmfg.Com ss-cpg36-72 w iring d iagram — cpg036/480453b (t hree -p hase , b elt d rive ) wiring is subject to change. Al wa ys refer to the wiring diag ram or the unit for the most up-to-da te wiring . ⚠ w arnin g high voltage: disconnect...
Page 39
P roduct s pecifications p roduct s pecifications ss-cpg36-72 www.Goodmanmfg.Com 39 a ccessories item # description fits model sizes field- installed factory- installed 14curb3672b 14" roof curb 3-6 tons √ 25fd3672 25% manual fresh air damper 3-6 tons √ 25mfd3672 25% motorized fresh air damper 3-6 t...
Page 40
P roduct s pecifications p roduct s pecifications 40 www.Goodmanmfg.Com ss-cpg36-72 goodman manufacturing company, l.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2012 • goodman manufacturing company, l.P. •...