    C us ® *note: please contact your distributor or our website for the applicable specification sheets referred to in this manual. Recognize this symbol as a safety precaution. Attention installing personnel prior to installation, thoroughly familiarize yourself with this installation manual. Observe ...

  • Page 2

    2 warning i nstallation and repair of this unit should be performed only by individuals meeting the requirements of an “e ntry l evel t echnician ” as specified by the a ir -c onditioning , h eating , and r efrigeration i nstitute (ahri). A ttempting to install or repair this unit without such backg...

  • Page 3

    3 important: to register your goodman ® brand unit, go to www.Goodmanmfg.Com and click “warranty registration”. Com- plete registration as prompted. To register your amana ® brand unit, go to www.Amana-hac.Com and click “warranty registration”. Complete registration as prompted. Product limited warr...

  • Page 4

    4 contained packaged units so the only connections needed for installation are the supply and return ducts, the line and low voltage wiring and drain connection. The units are etl listed and ahri certified. The information on the rating plate is in compliance with the ftc & doe rating for single pha...

  • Page 5

    5 • the unit may be installed directly on wood floors or on class a, class b, or class c roof covering material. • to avoid possible personal injury, a safe, flat surface for service personnel should be provided. Rooftop installation r oof c urb i nstallations o nly note: sufficient structural suppo...

  • Page 6

    6 remove these covers for horizontal duct applications remove these panels for downflow duct applications supply return duct cover installation down discharge applications cut insulation around bottom openings and remove panels from the bottom of the unit, saving the screws holding the panels in pla...

  • Page 7

    7 w i r i n g note: all wiring should be made in accordance with the national electrical code. Consult your local power company to determine the availability of sufficient power to operate the unit. Check the voltage, frequency, and phase at the power supply to ensure it corresponds to the unit’s ra...

  • Page 8

    8 branch circuit ampacity 15 20 25 30 35 40 45 50 supply wire length - feet 200 6 4 4 4 3 3 2 2 150 8 6 6 4 4 4 3 3 100 10 8 8 6 6 6 4 4 50 14 12 10 10 8 8 6 6 2. Wire size based on 60° c rated wire insulation and 30° c ambient temperature (86° f). 3. For more than 3 conductors in a raceway or cable...

  • Page 9

    9 crankcase thereby preventing liquid migration and subsequent compressor damage. The insert type heater is self regulating. It is connected electrically to the contactor l1 and l2 terminals. Condenser motor this item is activated by the contactor during heating and cooling, except during defrost an...

  • Page 10

    10 supplementary heat for all heat pump installations in areas where the temperature drops below 45° f. It is also a good practice to provide sufficient supplementary heat to handle the entire heating requirement should there be a component failure of the heat pump, such as a compressor, or refriger...

  • Page 11

    11 notes: • data shown is dry coil. Wet coil pressure drop is approximately: 0.1” h 2 0, for two-row indoor coil; 0.2” h 2 o, for three-row indoor coil; and 0.3” h 2 0, for four-row indoor coil. • data shown does not include filter pressure drop, approx. 0.08” h 2 0. • all models should run no less ...

  • Page 12

    12 s peed t ap a djustments f or i ndoor b lower m otor psc motor adjust the cfm by changing the speed tap of the indoor blower motor at the ebtdr “com” connection with one of the speed taps on “m1” or “m2”. (black-high speed, blue-medium speed, red- low speed.) eem motor adjust the cfm by changing ...

  • Page 13

    13 unit model number 5 8 10 15 20 gph1324m41** m ( f) m ( f) m (f) h na gph1330m41** m ( f) m ( f) m (f) h na gph/gpc1336m41** m m h (f ) h (f ) na gph1342m41** m m h (f ) h (f ) na gph/gpc1348m41** 3 (f ) 3 (f) 3 (f ) 3 (f) 3 ( f) gph/gpc1360m41** 3 (f ) 3 (f) 3 (f ) 3 (f) 3 ( f) gpc1336m43** --- -...

  • Page 14

    14 troubleshooting chart symptom high head - low suction a. Restriction in liquid line or flowrator a. Remove or replace with proper size flowrator. High head - high or normal suction a. Dirty condenser coil a. Clean coil. B. Overcharged b. Correct system charge. C. Condenser fan not running c. Repa...

  • Page 15

    15 appendix unit dimensions medium chassis gp*1324m4** gp*1330m4** gp*1336m4** gp*1342m4** large chassis gp*1348m4** gp*1360m4** blower access panel ? ? 2 34 51 47 supply 1 3/8 a return power wire entrance 4 1/8 2 1/8 6 ½ 16 16 5 ½ b b control wire entrance condensate drain connection 3/4” npt femal...

  • Page 16

    16 minimum clearances recommended filter sizes 3" min 12" min 36" min (for service) . 48" min 12" min 36" min (for service) note: roof overhand should be no more than 36” unit 2 ton 2-1/2 ton 3 ton 3-1/2 ton 4 ton 5 ton min. Filter size (1) 25x25x1 (1) 25x25x1 (1) 25x25x1 (1) 25x25x1 (2) 20x20x1 (2)...