Goodman GPG1324045M41A Series Specifications

Manual is about: 2- to 5-Ton C Packaged Gas/Electric Units 13 SEER / 80% AFUE

Summary of GPG1324045M41A Series

  • Page 1

    Ss-gpg13m www.Goodmanmfg.Com 12/11 supersedes 11/11 2- to 5-t on p ackaged g as /e lectric u nits c ooling c apacities : 23,600 to 57,000 btu/ h h eating c apacities : 46,000 to 138,000 btu/ h standard features • high-efficiency compressor • durable, corrosion-resistant t-140 aluminized steel tubula...

  • Page 2: Omenclature

    P roduct s pecifications p roduct s pecifications 2 www.Goodmanmfg.Com ss-gpg13m n omenclature brand g goodman® brand electrical 1 208-230/1/60 product category 3 208-230/3/60 p packaged unit refrigerant unit type 2 r-22 g gas/electric 4 r-410a configuration efficiency h horizontal 13 13 seer m mult...

  • Page 3: Pecifications

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 3 s pecifications gpg1324 045m41a* gpg1324 070m41a* gpg1330 045m41a* gpg1330 070m41a* gpg1336 045m41a* gpg1336 045m41c* cooling capacity total btu/h 23,600 23,600 28,600 28,600 36,000 35,000 sensible btu/h 18,800 18,800 2...

  • Page 4: Pecifications

    P roduct s pecifications p roduct s pecifications 4 www.Goodmanmfg.Com ss-gpg13m s pecifications ( cont .) gpg1336 070m41a* gpg1336 070m41c* gpg1336 090m41a* gpg1336 090m41c* gpg1342 070m41a* gpg1342 090m41a* cooling capacity total btu/h 36,000 35,000 36,000 35,000 40,500 40,500 sensible btu/h 27,80...

  • Page 5: Pecifications

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 5 s pecifications ( cont .) gpg1348 070m41a* gpg1348 090m41a gpg1348 115m41a gpg1360 090m41a gpg1360 115m41a gpg1360 140m41a cooling capacity total btu/h 46,000 46,000 46,000 57,000 57,000 57,000 sensible btu/h 36,700 36,...

  • Page 6: Xpanded

    P roduct s pecifications p roduct s pecifications 6 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1324xxxm41 outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 70...

  • Page 7: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 7 e xpanded c ooling d ata — gpg1324xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 ...

  • Page 8: Xpanded

    P roduct s pecifications p roduct s pecifications 8 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1330xxxm41 out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 7...

  • Page 9: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 9 e xpanded c ooling d ata — gpg1330xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 ...

  • Page 10: Xpanded

    P roduct s pecifications p roduct s pecifications 10 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1336xxxm41 outdoor ambient t emper ature 65 75 85 95 105 115 entering indoor w et bulb t emper ature idb airfl o w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 7...

  • Page 11: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 11 e xpanded c ooling d ata — gpg1336xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71...

  • Page 12: Xpanded

    P roduct s pecifications p roduct s pecifications 12 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1342xxxm41 out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 ...

  • Page 13: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 13 e xpanded c ooling d ata — gpg1342xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71...

  • Page 14: Xpanded

    P roduct s pecifications p roduct s pecifications 14 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1348xxxm41 out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 ...

  • Page 15: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 15 e xpanded c ooling d ata — gpg1348xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71...

  • Page 16: Xpanded

    P roduct s pecifications p roduct s pecifications 16 www.Goodmanmfg.Com ss-gpg13m e xpanded c ooling d ata — gpg1360xxxm41 out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 ...

  • Page 17: Xpanded

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 17 e xpanded c ooling d ata — gpg1360xxxm41 ( cont .) out door ambien t t emper atur e 65 75 85 95 105 115 en tering indoor w et bulb t emper atur e idb airflo w 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71 59 63 67 71...

  • Page 18: Irflow

    P roduct s pecifications p roduct s pecifications 18 www.Goodmanmfg.Com ss-gpg13m a irflow d ata for psc m otors gpg13m— 2-t on m odels motor speed high med low e.S.P. Cfm watts rpm amps cfm watts rpm amps cfm watts rpm amps 0.1 1,190 380 823 1.67 850 230 647 1.02 600 150 514 0.67 0.2 1,140 360 845 ...

  • Page 19: Irflow

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 19 a irflow d ata for eem m otors gpg13m– 4-t on m odels — h eating speed t1 t2 t3 e.S.P cfm watts rpm amps cfm watts rpm amps cfm watts rpm amps 0.1 --- --- --- --- --- --- --- --- --- --- --- --- 0.2 914 125 611 1.07 1,...

  • Page 20: Emperature

    P roduct s pecifications p roduct s pecifications 20 www.Goodmanmfg.Com ss-gpg13m t emperature r ise r ange c hart 27 blower performance data 30 40 50 60 70 80 90 11 0 12 0 10 0 13 0 14 0 15 0 10 0 90 80 70 60 50 40 30 20 10 o u t pu t bt u /h r x 1 00 0 b t u o u t p u t v s t e m p e r a t u re r ...

  • Page 21: Imensions

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 21 d imensions model chassis size a b gpg1324xxxm41 medium 32” 16” gpg1330xxxm41 medium 32” 16” gpg1336xxxm41 medium 32” 16” gpg1342xxxm41 large 40” 18” gpg1348xxxm41 large 40” 18” gpg1360xxxm41 large 40” 18” 7 package ga...

  • Page 22: Iring

    P roduct s pecifications p roduct s pecifications 22 www.Goodmanmfg.Com ss-gpg13m w iring d iagram — gpg1324-42m41 8 7 6 5 4 2 1 3 8 7 6 5 4 2 1 3 e d b a c e d b a c confidential property of the goodman manufacturing company, l.P. Not to be disclosed to others, copied, or used for any purpose excep...

  • Page 23: Iring

    P roduct s pecifications p roduct s pecifications ss-gpg13m www.Goodmanmfg.Com 23 w iring d iagram — gpg1348-60m41 8 7 6 5 4 2 1 3 8 7 6 5 4 2 1 3 e d b a c e d b a c confidential property of the goodman manufacturing company, l.P. Not to be disclosed to others, copied, or used for any purpose excep...

  • Page 24: Ccessories

    P roduct s pecifications p roduct s pecifications 24 www.Goodmanmfg.Com ss-gpg13m goodman manufacturing company, l.P., reserves the right to discontinue, or change at any time, specifications or designs without notice or without incurring obligations. © 2011 • goodman manufacturing company, l.P. • h...