  • Page 1

    Mbvc blowers • refer to service manual rs6200007 for installation, operation, and troubleshooting information. • all safety information must be followed as provided in the service manual. • refer to the appropriate parts catalog for part number information. • models listed on page 2. Rt6223003 septe...

  • Page 2: Product Identification

    Product identification 2 the model number is used for positive identification of component parts used in manufacturing. Please use this number when requesting service or parts information. Mbvc1200aa-1aa mbvc1600aa-1aa mbvc2000aa-1aa warning warning high voltage! Disconnect all power before servicin...

  • Page 3: Product Design

    Product design 3 g eneral i nformation the mbvc blower cabinets are used in combination with a cased evaporator coil for a two-piece blower and coil combi- nation. This combination of blower and coil functions as the indoor part of a split air-conditioning system, and may be matched with a remote co...

  • Page 4: Mbvc Blower Specifications

    Mbvc blower specifications 4 w h (3) knockouts 1.125 1.375 1.750 .875 knockout (2 places) c 6 1/2 5 5 1/8 3 1/4 d mbvc1200/1600/2000 physical information shipping blower wheel (d x w) blower motor (hp) mca 1 mop 1 w h d weight lbs.(kg) mbvc1200 10x8 1/2 4.3 15 17½ (445) 26 (660) 21 (533) 72 (32.6) m...

  • Page 5: Mbvc Blower Specifications

    Mbvc blower specifications 5 blower opening dimensions (top view) mbvc1200/1600/2000 hkr heater data no heat kit hkr-03* hkr05-(c)* hkr-06* hkr-08(c)* mbvc 1200aa-1aa x x x x x 1600aa-1aa x x x x x 2000aa-1aa x x x x x ^ = circuit 1: single phase for air handler motor * = revision level that my or m...

  • Page 6: Blower Performance Data

    Blower performance data 6 3 4 normal* +10% air flow adjust taps (*indicates factory setting) -10% normal off off off off on on on on 3 4 3 4 3 4 thermostat "fan only" mode during "fan only" operations, the cfm output is 30% of the maximum cfm capability. Cfm trim adjust minor adjustments can be made...

  • Page 7: Wiring Diagrams

    Wiring diagrams 7 high voltage! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-d...

  • Page 8: Wiring Diagrams

    Wiring diagrams 8 high voltage! Disconnect all power before servicing or installing this unit. Multiple power sources may be present. Failure to do so may cause property damage, personal injury or death. Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-d...