H2W Technologies LCAM 5/15 Operation & Service Manual - Technical Specifications
H2W Technologies, Inc., 26470 Ruether Ave. #102, Santa Clarita, CA 91350, U.S.A. (888) 702-0540
8
TECHNICAL SPECIFICATIONS
Output
LCAM 5/15: 15A peak, 5A continuous, (forced air cooling required)
Note: Large motor and Small motor versions have different velocity loop compensation.
Input
LCAM 5/15: 24-75VDC
Integral forced air fan cooling (multi-axis LCAM 5/15 only)
Analog command signals: differential & single ended, adjustable gain
Reset: LCAM 5/15: pull up/pull down, active high only
Inhibit: Same as Reset
+/- Limits: Same as Reset
Output Connections
Motor : MTR + & MTR-
Fault out: LCAM 5/15: Optically isolated can sink up to 50 mA, active high only
Bandwidth
10 kHz maximum and varies with motor inductance
Status Indicator
LCAM 5/15: Green Run LED, Red Inhibit LED, Red Fault LED
Mechanical
LCAM 5/15 module: Height: 7.13”, Width: 2.23”, Depth: 5.69”
LCAM 5/15 2-Axis: Height: 10.75”, Width: 9.75”, Depth: 6.93”
LCAM 5/15 4-Axis: Height: 10.75”, Width: 14.90”, Depth: 6.93”
Environmental
Operating temperature 0 to 55°C
Storage temperature -40 to 80°C
Humidity 5 – 95% relative (non-condensing)