H3C MS8000 User Manual

Manual is about: Media Switch Server

Summary of MS8000

  • Page 1

    H3c ms8000 media switch server user manual hangzhou h3c technologies co., ltd. Http://www.H3c.Com manual version: t2-08019e-20081202-c-2.01.

  • Page 2

    Copyright © 2008, hangzhou h3c technologies co., ltd. And its licensors all rights reserved no part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of hangzhou h3c technologies co., ltd. Trademarks h3c, , aolynk, , h 3 care, , top g, , irf, n...

  • Page 3

    About this manual organization h3c ms8000 media switch server user manual describes the appearance, features, installation, configuration, and management for h3c ms8000 media switch server (hereinafter referred to as the ms8000). This document is organized as follows: chapter contents 1 overview des...

  • Page 4

    Obtaining documentation you can access the most up-to-date h3c product documentation on the world wide web at this url: http://www.H3c.Com. The following are the columns from which you can obtain different categories of product documentation: [products & solutions]: provides information about produc...

  • Page 5: Table of Contents

    I table of contents 1 overview ·····················································································································································1-1 features ···········································································································...

  • Page 6

    Ii introduction······································································································································4-6 viewing system logs ······················································································································4-6 displ...

  • Page 7: Overview

    1-1 1 overview h3c ms8000 (hereinafter referred to as the ms8000) is a media switch server developed by hangzhou h3c technologies co., ltd. (h3c). It is an important component in the h3c ip video surveillance system (ivs) solution. Figure 1-1 shows its appearance. Figure 1-1 ms8000 appearance featur...

  • Page 8

    1-2 appearance front view figure 1-2 ms8000 front view (1) power switch (2) power led (pwr) (3) alarm led (alm) (4) running led (run) table 1-1 description for the leds led color status meaning blinking the ms8000 is starting up. Steady on the ms8000 has started up. Pwr green off the ms8000 is not p...

  • Page 9

    1-3 technical specifications table 1-2 ms8000 hardware specifications item description cpu 2.8 ghz 2m cache xeon processor memory (ram) 2 gb physical dimensions (h × w × d) 43.6 × 430 × 503.4 mm (1.72 × 16.93 × 19.82 in.) weight 9.4 kg (20.72 lb) input voltage 100 vac to 127 vac/200 vac to 240 vac, ...

  • Page 10: Device Installation

    2-1 2 device installation precautions to ensure its proper operation and extend its longevity, consider the precautions when installing the ms8000: z install the ms8000 indoors. Z install the ms8000 in a place with good ventilation, especially around the heat dissipation holes. Do not place any obje...

  • Page 11

    2-2 before installation before installing the ms8000: z verify the equipment model, and the type and quantity of accessories against the packing list. Z make sure you have reviewed the content in the "precautions" section on page 2-1, and all requirements are met. Z prepare a flathead screwdriver an...

  • Page 12

    2-3 figure 2-2 install mounting brackets and inner slide rails (1) (2) (3) (4) (1) (2) (3) (4) (1) four screws (2) mounting brackets (3) slotted hole (4) inner slide rail step2 as shown in figure 2-3, fix the outer slide rails to the rack posts on the same height at the two rear sides of the rack wi...

  • Page 13

    2-4 table 2-1 verification list for ms8000 result no. Item yes no remarks 1 the mounting brackets and inner slide rails are fixed to the ms8000 tightly. 2 the ms8000 is installed at an appropriate position. 3 the outer slide rails are fixed on the rack posts at the rear of the rack. 4 the inner and ...

  • Page 14

    2-5 if your ms8000 is installed in a 19-inch rack, you can lay the cables either over the top or below the bottom of the rack according to the actual situation (whether the signal cables of the equipment room are wired on the rack top or below the rack bottom). Z do not bundle cables near the heat d...

  • Page 15

    2-6 connecting the ac power cable the ms8000 ships with a cable retention clip. Before connecting the power cable, install the cable retention clip first. Step1 ensure that the power switch of the ms8000 is off, and the power cable retention clip has been installed on the ms8000 correctly. Step2 con...

  • Page 16

    2-7 after installation before performing the check, make sure that the device is powered off, to avoid bodily injury or equipment damage caused by incorrect cable connection. After the ms8000 is installed, check the following: z the ms8000 is installed securely with all screws fixed tightly. Z no ob...

  • Page 17: Initial Configuration

    3-1 3 initial configuration perform the initial configuration under the guide of h3c technicians to avoid exceptions. Prerequisites before logging in to the ms8000, make the following prerequisite tasks: z plan the system configuration, such as the ms8000 ip address and device id. Z ms8000 is operat...

  • Page 18

    3-2 task remarks configuring parameters for the ms8000 services configure operation parameters for the ms8000 services. Restarting ms8000 services starting the ms8000 services. Configuring host name if multiple ms8000s are installed in the network, you have to configure their hostnames. Suppose the ...

  • Page 19

    3-3 use the ethtool eth1 command to check that the settings of interface eth1, the link speed, and dual-duplex status are correct. The "link detected:yes" in the display means that the connection is up. If there is no such display, check the cable connection. [root@msserver ~]# ethtool eth1 settings...

  • Page 20

    3-4 z the device ip must be unique in the network. Z after the modification, press esc, and then enter :wq! If you want to save the changes and exit, or enter :q! If you want to exit without saving the changes. Z after the services restarts, the ip address is changed. Log in to the ms8000 using the ...

  • Page 21

    3-5 after opening the configuration file, type i to enter the edit status of the file. After the modification, press esc, and then enter :wq! If you want to save the changes and exit, or enter :q! If you want to exit without saving the changes. Restarting ms8000 services step1 after configuration, u...

  • Page 22: Web-Based Management

    4-1 4 web-based management the ms8000 provides web interfaces for configuration management, including: z system management z log management z user management z traffic statistics z two categories of users are in the ms8000: super administrator and common administrator. They operate based on the perm...

  • Page 23

    4-2 figure 4-1 layout of the web interface z the menus in the navigation area and tab in the operation area provide entries to specific configuration pages. Z after your first-time login, you are recommended to modify the login password. For details, refer to the "changing password" section on page ...

  • Page 24

    4-3 displaying version information select system management. The page displays the software version by default. Configuring communication protocol parameters on the communication protocol page, you can configure the protocol parameters of the ms8000 to communicate with the vm8000. To configure the c...

  • Page 25

    4-4 figure 4-4 configuration management step2 if you want to export the current system configuration, click export. In the pop-up dialog box, select save to bring up another dialog box. Select the directory to save the file and click save. Step3 if you want to import the system configuration click b...

  • Page 26

    4-5 displaying device information the ms8000 allows you to display the current information of the server. You can check the information in real time against the normal range. This greatly facilitates the server maintenance. Select system management, and then select the device status tab to enter the...

  • Page 27

    4-6 log management introduction the logs record key events that happened in the ms8000. Two types of logs are recorded, system logs and operation logs. Z system logs: record events that occurred during the ms8000 operation. Z operation logs: record configuration made by the administrator. The log ma...

  • Page 28

    4-7 z click refresh to view the latest log information. Z only the logs of the past three months can be queried and displayed. Displaying operation logs select log management, and then select the operation log tab to enter the page displaying the operation logs. Figure 4-9 operation log list z click...

  • Page 29

    4-8 figure 4-10 query logs step2 specify the query conditions. You can specify the event level if you select to query system logs. This is not available for operation logs. Step3 click the calendar icon and set the start and end time as required. The start time must be ahead of the end time. Step4 c...

  • Page 30

    4-9 step3 click export. A dialog box appears. Step4 choose to save the file and then select the directory for the file to be saved in the pop-up save as dialog box. Click save. The logs are saved locally in compressed files. Unzip the file and open the file in text format to view the logs. User mana...

  • Page 31

    4-10 adding a user only the super administrator has the permission to add users to the system. To add a user, follow these steps: step1 select user management to enter the page listing the users. Step2 click add to enter the page for adding a user, as shown in figure 4-13. Figure 4-13 add a user ste...

  • Page 32

    4-11 step4 input yes in the confirmation dialog box and click ok. The system performs the operation and displays the result later. Resetting password only the super administrator has the right to reset passwords for users. Common administrators can ask the super administrators to reset the passwords...

  • Page 33

    4-12 figure 4-14 traffic statistics displaying vod traffic statistics select traffic statistics to enter the page as shown in figure 4-14. The vod traffic tab is displayed by default. The information about the vod service status is displayed, including the media url, speed rate, and client ip addres...

  • Page 34

    4-13 figure 4-16 forwarding traffic statistics.

  • Page 35

    5-1 5 compliance and safety manual for ms8000 regulatory compliance information regulatory compliance standards table 5-1 regulatory compliance standards discipline standards emc z fcc part 15 (cfr 47) class a z ices-003 class a z vcci-3 class a z vcci-4 class a z cispr 22 class a z en 55022 class a...

  • Page 36

    5-2 weee directive–2002/96/ec the product this manual refers to is covered by the waste electrical & electronic equipment (weee) directive and must be disposed of in a responsible manner. Usa regulatory compliance fcc part 15 ms8000 complies with part 15 of the fcc rules. Operation is subject to the...

  • Page 37

    5-3 japan regulatory compliance vcci ms8000 complies with the requirements of vcci class a information technology equipment (ite). Warning: if this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions....

  • Page 38

    5-4 anmerkung lesen sie bitte alle arbeitsanweisungen und sicherheitvorschriften sorgfältig durch, bevor sie mit dem arbeiten beginnen. Nur durch beachtung dieser hinweise lässt sich das unfallrisiko minimieren. Die in anderen handbüchern aufgeführten symbole anmerkung, achtung, warnung und gefahr b...

  • Page 39

    5-5 table 5-2 safety symbol and description sicherheitssymbole und beschreibung 安全标识和描述 safety symbol symbole 安全标识 description erläuterung 描述 generic alarm symbol: to suggest a general safety concern alarm: hinweis auf ein generelles sicherheitsproblem 一般注意标识:用于一般安全提示 esd protection symbol: to sugge...

  • Page 40

    5-6 z for ac supplied model: the plug-socket combination must be accessible at all times because it serves as the main disconnecting device. Z mit wechselstrom betriebenes modell: der netzstecker muss jederzeit leicht zugänglich sein. Z ac 供电:插座必须随时可用,因为它是主要的切断电源装置。 z because the device has several ...

  • Page 41

    5-7 z sollte sich wasser im baugruppenträger befinden oder der baugruppenträger feucht sein, ist die energiezufuhr sofort zu unterbrechen und das system abzuschalten. Z 当有液体进入机架或机架有损坏时,请立即切断电源。 z when operation is performed in a damp environment, make sure that water is kept off the equipment. Z mus...

  • Page 42

    5-8 anmerkung das entfernen und anbringen von zuleitungen ist strengstens verboten. Kurzschlüsse zwischen innerem und äußerem leiter können lichtbögen oder funkenflug verursachen, was zu feuer oder einer augenverletzung führen kann. 禁止安装和移动带电的线缆。因为导电体和带电的线缆,即使短暂接触,也会引起电火花或电弧,从而 导致失火或是伤害眼睛。 z before ...

  • Page 43

    5-9 thunderstorm gewitter 防雷击 danger high voltage and ac operations or operations on a steel tower and a mast on a thunderstorm day are prohibited. In order to prevent the equipment from being damaged by lightning, proper grounding is required. Gefahr arbeiten mit hochspannung und wechselstrom oder ...