    Art. No.0499132299030 v09 g22 fireplace inserts en13229-w installation and operating manual nameplate: our supply program: oil heaters chimney stoves pellet stoves glazed tile and slow-burning stoves for wood and coal slow-burning stoves and cooking stoves for wood, coal and oil fireplace inserts fo...

  • Page 2

    Table of contents 1.Description 3 2. General instructions, safety instructions 3 3. Combustion air supply: 3 4. Suitable chimney: 4 5. Data for chimney calculation: 4 7. Installation of fireplace insert and connection to the chimney 5 7.1 connecting piece (flue gas pipe): 5 7.2 protection of install...

  • Page 3

    1.Description fireplace inserts are highly suitable for the heating of living and working rooms. The stove body consists of a welded steel structure. At the bottom is a wood storage compartment and above it the ash box, on top of that the firebox and a heat exchanger at the top. Between the latter t...

  • Page 4

    Be a minimum inflow to the heating inserts of 540 m³/h of combustion air for each m² of firebox opening and additionally at least 1.6 m³ of combustion air per hour for other fireplaces and for each kw of total rated heat output with a calculated pressure differential of 4 pa relative to the outside....

  • Page 5

    6. Room heating capacity according to din 18893: in this regard, please note the details on the equipment sheet. The values relate to rooms which do not correspond to the heat protection regulations. For rooms with a room volume in excess of 200m 3 a heat requirement calculation according to din 470...

  • Page 6

    7.4 chimney connection: if the existing chimney does not have a suitable shaped connection piece for the fireplace insert a subsequent connection has to be established. The chimney connection height is obtained from the correctly placed fireplace insert plus fitted smoke gas bend and connecting piec...

  • Page 7

    7.7 permissible heat insulation and primary walling material (minimum requirements) : 1. Insulation materials: insulation materials according to agi working sheet q 132: 12.07.21.70.09 (=insulation material code number). This means: insulation material group 12, type: stone wool, form of delivery gr...

  • Page 8

    8.5 ornamental beams: ornamental beams in front of the covering of the fireplace insert are permissible at a distance of at least 1 cm if the ornamental beam is not part of the building and the intermediate spaces to the covering are clear so that no heat congestion can develop and the ornamental be...

  • Page 9

    9. Installation drawing: fireplace insert according to din 18895 /en13229 without factory-made convection air jacket 1. Ceiling to be protected of combustible components or as carrying building element 2. Substitute material: carry out heat protection measure according to din 18160 4. Connecting pie...

  • Page 10

    Caution! Wood it not a slow-burning fuel so that continuous heating of the fireplace with fuel overnight is not possible. The fireplace insert is intended for the burning of dry billet wood with a maximum water content of 30% of the dry weight. Billet wood should be stored in airy and dry places for...

  • Page 11

    11.3 maximum fuel charge quantity of approximately 1 hour: total quantity fuel quantity esprit 185.16 komfort 180.18, prestige 181.18, exquisit 182.18 trend 184.18, opus 186.18 billet wood 2 – 3 billets 2,0 kg 2,5 kg wood briquettes 4 – 5 small pieces (divide large briquettes if required) 1,8 kg 2,1...

  • Page 12

    13.2 warranty directives: 1. Haas + sohn accept guaranty for the duration of three years calculated from the delivery to the end user for a) unobjectionable material condition and workmanship to suit the purpose, b) expert assembly, c) adherence to the rated heat output (watt) according to din 18895...