HAAS + SOHN FIREPLACE INSERT General Instructions For Operation, Installation And Maintenance

Summary of FIREPLACE INSERT

  • Page 1

    General instructions for operation, installation and maintenance fireplace insert haas + sohn rukov s.R.O. Manufacturer: snp 474, 408 01 rumburk, czech republic company id: 62740989 tax id: cz62740989 contents 1. Technical specifications .................................................................

  • Page 2

    10.6. Haas+sohn rukov s.R.O products and manufacturing programme.................................. 17 11. Supplements...............................................................................................................17-19 congratulations! You have just bought the fireplace insert haas + ...

  • Page 3

    The inner space of the firing chamber is usually lined with fireclay brick shapes. The brick shapes are not jointed with any filler (the reason is a protection of the bricks against damage by thermic dilatation). The upper part of the firing chamber is equipped with partitions designed for directing...

  • Page 4

    3.2. Safe distance between the fireplace insert and flammable material if you have installed a fireplace insert within the room with flammable objects, flammability class b, c1 and c2, the safety distance from the front (or side glass surfaces) is 800 mm; for the other directions, the safety distanc...

  • Page 5

    4.5. Cleaning the heating device and chimney it is necessary to provide approach to the piping (smoke path) for occasional cleaning by means of, for example, a removable part of the casing at the area of the smoke flue. We recommend you to advise of the requirement the company whose technicians will...

  • Page 6

    5.4. Glass cleanness the cleanness of the transparent glass depends on the type of the fuel, proper combustion air supply (this is applied especially to the secondary air) , the chimney effect and – last but not least – on the way how the fireplace insert is operated. It is recommended to load one l...

  • Page 7

    7. What to do if... ...Do you do it yourself? Problem cause corrective action chimney or smoke flue sealing (malfunction, “false” air is being added). Contact a chimney sweep (ask them to check the chimney). For example, new sealing for the chimney door is needed. Adjust the positions of smoke pipes...

  • Page 8

    8.4. Blind element substituted with exchanger (optional) disassembly: use a wrench (proper size) to unscrew the nuts from the blind element. Remove it from the insert construction. Assembly: before you install the exchanger, carefully clean the contact area. Remove any remaining parts of the previou...

  • Page 9

    Disposal: insert body and stone lining. For the disposal after the service life, sort the fireclay, vermiculite panels, glass and sealing tapes as solid communal garbage. Sort the metal corpus and other metal components for the waste collecting point. 10.5. Es declaration of conformity and ce certif...

  • Page 10

    Example: protective barrier for the heating device and smoke flue (dimensions in mm) printed: tiskÁrna Ř ehÁk Č eská lípa, czech republic, tel.: +420 487 853 897 passage through the fire proof smoke flue wall (dimensions in mm) 1 – wall 2 – smoke flue system 3 – cover (fireproof, non-metal) 4 – rose...