Hafler GX2300 Owner's Manual

Manual is about: 2-channel Audio Power Amplifier

Summary of GX2300

  • Page 3

    – 1 – table of contents declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 safety information . . . . . . . . . . . . . ....

  • Page 4

    – 2 – declaration of conformity application of council directive: 73/23/eec (low voltage directive) application of council directive: 89/336/eec (emc directive) standard(s) to which conformity is declared: en55103 -1 (emissions) en55103 -2 (immunity) en60065 (safety) manufacturer’s name: hafler manu...

  • Page 5: C A U T I O N

    – 3 – notice - important safety information 1. Read instructions all the safety and operating instructions of your hafler equip- ment should be read before power is applied to the equipment. 2. Retain owner's manual these safety and operating instructions should be retained for future reference. 3. ...

  • Page 6: P E L I G R O

    – 4 – advertencia – informacion de seguridad importante el símbolo de flecha relámpago dentro de un triángulo equi- látero, es para alertar al usario de la presencia de “voltajes peli- grosos” no aislados en el interior del aparato, los cuales pueden ser de suficiente magnitud para constituir un rie...

  • Page 7: A C H T U N G

    – 5 – achtung – wichtige sicherheits – informationen 1. Instruktionen lesen alle sicherheits- und operationshinweise ihres hafler equipments sollten vor der inbetriebnahme gelesen werden. 2. Betriebsanleitung aufbewahren bewahren sie die bedienungsanleitung sorgfältig auf, damit sie in dieser auch i...

  • Page 8: A T T E N T I O N

    – 6 – attention: informations importantes de sÉcuritÉ 1. Lire les instructions le mode d'emploi et les mesures de sécurité de votre équipement hafler devraient être consultés avant sa mise en marche. 2. Conserver le guide de l'utilisateur le mode e'emploi et les mesures de sécurité devraient être co...

  • Page 9: A T T E N Z I O N E

    – 7 – notare – importanti informazioni sulla sicurezza 1. Leggete le istruzioni tutte le istruzioni riguardanti la sicurezza ed il funzionamento devono essere lette prima di applicare tensione all'apparato. 2. Conservate il manuale queste istruzioni riguardanti la sicurezza ed il funzionamento devon...

  • Page 10

    – 8 – all measurements taken at normal operating conditions (i.E. 1/8th rated output power) unless noted otherwise. Power rating: 8 Ω 20-20khz @ 0.1% thd 300w x 2 ch 600w x 2 ch 4 Ω 20-20khz @ 0.2% thd 300w x 2 ch 600w x 2 ch 2 Ω 20-20khz @ 0.3% thd 300w x 2 ch 600w x 2 ch 70v 20-20khz @ 0.2% thd 60...

  • Page 11

    The hafler gx2300 and gx2600 amplifiers are two rack height, two channel, fan-cooled professional power amplifiers suitable for use in the most demanding sound reinforcement and commercial sound installations. These amplifiers offer out- standing efficiency by means of three technologies: high-effic...

  • Page 12

    – 10 – what else distinguishes these amplifiers? Constant power into varying impedance. It takes twice as much current to develop a given wattage into 2 Ω as it does into 8 Ω—but only half the voltage. Many amplifiers quote a high output current at 2Ω but have an unpublished operating time measured ...

  • Page 13

    – 11 – 1. Recessed front panel - prevents switches and controls from acci- dentally being adjusted or broken. 2. Power switch - turns the amplifier on and off 3. Power leds - verifies that the amplifier channel is on 4. Status leds - displays the status of the amplifier. The leds are as follows: sig...

  • Page 14

    The gx2300/2600 is a standard 2u (2 rack height) 19" rack-mount unit, with both front and rear rack mounting ears. In portable systems, the amplifier must be supported at both the front and rear. Cooling the gx2300/2600 uses forced-air cooling (fan cooling) to remove the heat produced during normal ...

  • Page 15

    – 13 – audio ground chassis/float switch in general, the audio ground of each amplifier should be connected to ac mains earth ground at one point only- either through the chassis (by selecting the "chassis" position) or through the input cable (with the switch in the "float" position, and pin 1 of t...

  • Page 16

    – 14 – the amplifier will operate with either a balanced or unbalanced signal source. Input the input jacks used on the gx2300/2600 are dual function connectors which accept 1/4 " trs (tip ring sleeve) or male xlr plugs. The amplifier will operate with either a balanced or unbalanced signal, from ea...

  • Page 17

    – 15 – floated source equipment source units with a 2-pin mains power cord have no means to connect the audio output ground to earth ground, so usually the audio output ground is floated from earth ground. However, this does not insure that when installed in a system, the audio output ground will re...

  • Page 18

    – 16 – delay (one of these switches must be selected. If all the switches are off, there will be no output signal.) the delay feature provides five sections of 2nd-order all-pass delay filters of 450µsec +/-10µsec each. Unlike the more commonly used 1st-order all-pass, the 2nd-order filters achieve ...

  • Page 19

    – 17 – level controls the gain for each channel can be controlled individually using the front panel level control. The controls have 32 detented positions that are calibrated in db. The maximum gain position is marked as the "0 db" position, and the lower gain posi- tions indicate the amount of att...

  • Page 20

    – 18 – load switch the load switch - located on the front panel - allows the amplifier power supply to be matched to the speaker load for more efficient, cooler running operation.This unique feature of the gx2300/2600 allows each channel to be configured for 2 Ω, 4Ω, 8Ω, or 70v, 100v mono operation....

  • Page 21

    – 19 – 1. Connect signal from source to both ch a and ch b inputs. 2. Move stereo/biamp switch to stereo input mode. 3. Move stereo/mono switch to stereo mode. 4. Select desired speaker load (8 Ω/4Ω/2Ω) for each channel – ch a & ch b loads do not need to match. 5. Connect appropriate speaker load 8 ...

  • Page 22

    – 20 – 1. Connect signal from source to ch b input. 2. Stereo/biamp switch not active (stereo/mono switch overrides this switch when in mono/70v/100v mode). 3. Move stereo/mono switch to 70v mode. 4. Select 70v load, both channels. 5. Connect parallel array of 70v transformer-equipped speakers acros...

  • Page 23

    – 21 – 1. Connect signal from source to ch b input. 2. Stereo/biamp switch not active (stereo/mono switch overrides this switch when in mono/70v/100v mode). 3. Move stereo/mono switch to 100v mode. 4. Select 100v load, both channels. 5. Connect parallel array of 100v transformer-equipped speakers ac...

  • Page 24

    – 22 – hafler offers a limited warranty on hafler products on the following terms: • length of warranty 5 years on gx2300 & gx2600 • what is covered this warranty applies only to products sold to the original owner (non-transferable). This only applies to units sold in the continental united states....

  • Page 25

    – 23 – pc board layouts x70 x69 x68 x67 x65 x64 x63 x62 x61 x60 x53 x6 x2 x9 x51 x66 x50 x49 x36 x34 x23 x22 x57 x56 x55 x48 x47 x46 x45 x44 x52 x42 x41 x28 x26 x27 x30 x31 x29 x38 x39 x32 x33 x37 x35 1/v agnd agnd out i-n 1/v 1/v i-p i-n test1 i-p 1/v mono stereo high voltage ct -rail +rail vfan -1...

  • Page 26

    – 24 – j9 j10 j16 j3 j5 j1 c5 c3 c2 r2 l2 l1 l3 c6 c1 c4 r3 c7 r1 j12 j11 r4 j8 j15 j13 j7 j6 j14 danger - high voltage 230v 230v 120v 120v org org wht wht black black ks4r pc-2460-e hafler j4 j2 emi filter crossover cd eq pc board layouts.

  • Page 27

    – 25 – pc board layouts time delay/phase inverter.

  • Page 28

    – 26 – bridge rectifier schematic diagrams.

  • Page 29

    – 27 – pc-2460-e.Sch-1 emi filter.

  • Page 30

    – 28 – crossover cd eq schematic diagrams.

  • Page 31

    – 29 – time delay/phase inverter.

  • Page 32

    – 30 – amplifier.

  • Page 33

    – 31 – c600_maualb.Sch-1.

  • Page 34

    – 32 – protection.

  • Page 35

    C600_maualb.Sch-2 – 33 –.

  • Page 36

    G – 34 – high voltage control.

  • Page 37

    – 35 – gx 2300

  • Page 38

    – 36 – housekeeping control.

  • Page 39

    – 37 – c600_maualb.Sch-6.

  • Page 40

    – 38 – input.

  • Page 41

    – 39 – c600_maualb.Sch-8.

  • Page 42

    – 40 – power.

  • Page 43

    – 41 – c600_maualb.Sch-5.

  • Page 44

    A division of rockford corporation 546 south rockford drive tempe, arizona 85281 u.S.A. In u.S.A. (480) 967-3565 / in canada, (604) 942-1001 in europe, fax 8503-9340-14 / in japan, fax (81) 559-79-01265 ® man-2987-a 6/00 mjt.