Five-Button Controller, Cont.
Button
Function
Buttons
The
CHANGE
(C),
SELECT
(S),
DISPLAY
(P), and
SCROLL BACK
(
) buttons are used when
changing Customer Settings and Service Settings.
REGENERATE
(R) The
REGENERATE
(R) button can be used in three ways.
1.
The
REGENERATE
(R) button can be used to put the appliance into an immediate regeneration.
a.
Press and hold the
REGENERATE
(R) button for about five seconds until the display
changes to “Going to 1”.
b.
The appliance is in regeneration mode and will display the status of each cycle. After all
regeneration cycles are complete, the display will return to normal operating mode.
2.
The
REGENERATE
(R) button can be used to toggle through all of the regeneration cycles to
speed up the cycles.
a.
Speeding up the cycle is used only when starting up or diagnosing the appliance.
b.
To quickly advance through the regeneration cycles, press and hold the
REGENERATE
(R)
button for five seconds to start a regeneration.
c.
Wait for the cycle to begin. The controller will indicate “Going to”, then the cycle position will
display (for example, Backwash 1).
d.
Each cycle can be advanced by pressing the
REGENERATE
(R) button.
e.
Always wait until the cycle position displays before advancing to the next cycle position.
3.
Press and release the REGENERATE (R) button in Normal operating mode to schedule a
regeneration tonight or toggle it off.
Out of Salt
Should your appliance run out of salt, you might not have soft water available.
1.
Open the salt port lid and add salt.
2.
Wait two hours, then press and hold the
REGENERATE
(R) button for 2 to 5 seconds.
3.
Regeneration is complete after approximately 12 to 18 minutes. After regeneration the appliance
is returned to Service mode.
CHANGE
(C)
The
CHANGE
(C) button is used with the
SELECT
(S) button to set the value of certain parameters.
1.
When you press the
CHANGE
(C) button, the value under the cursor changes to the next
available value, typically increasing by one until all values have been displayed and the process
begins again.
SELECT
(S)
The
SELECT
(S) button is used to move the cursor when setting parameters.
1.
Press and release the
SELECT
(S)
button to move the cursor one digit to the right of the
parameter to be changed.
2.
When the cursor is at the extreme right position, press the
SELECT
(S)
button again to reset the
cursor to the extreme left position.
DISPLAY
(P)
The
DISPLAY
(P) button is used to enter programming modes and also to save a value and display
the next value to be changed.
1.
To program Customer Settings, press and hold the
DISPLAY
(P)
button for about 5 five seconds
while “Customer Setting” is displayed.
2.
To program Service Settings, press and hold both the
DISPLAY
(P)
button and the
SELECT
(S)
button while “Service Setting” is displayed.
3.
To reset the factory defaults, press and hold both the
DISPLAY
(P)
button and the
SCROLL BACK
(
)
button for about five seconds.
SCROLL BACK
(
)
The
SCROLL BACK
(
) button function is used to step back to a previous parameter setting. It is
typically used to go back to correct a setting without the need to scroll forward through all settings.