Manual is about: Two Speed Heat Pump 3 Stage Heat / 2 Stage Cool With Energy Efficient Control

Summary of RC-112

  • Page 1

    1 1 rc-112 / rc-112b two speed heat pump 3 stage heat / 2 stage cool - with energy efficient control thermostat installation instructions application this rc-112 thermostat is applicable to heat pumps with two stages of heating and cooling, plus a third stage of heating called "auxiliary" heating. T...

  • Page 2: Figure 1

    2 2 1. Ensure that the thermostat is mounted 5 feet above the floor and is at least 2 feet from an outdoor wall. 2. Ensure that the thermostat is located in an area where there is adequate air circulation. 3. Do not mount in the path of direct sunlight or of radiant heat generated by appliances. 4. ...

  • Page 3: Figure 2

    3 3 connect each wire to the terminal strip on the thermostat base per the wiring diagram for your system application - see figures 4 - 5. Form the thermostat wiring so that the cable lies flat between the terminal strip and the center of the base. If a remote system is being used with the thermosta...

  • Page 4: Caution:

    4 4 typical wiring diagrams caution: be sure to disconnect the power to the control transformer before removing or installing thermostat. Do not short compressor relays, fan relay, auxiliary heat relay, or reversing valve...Even momentarily. This will blow a non-replaceable fuse. Do not attempt to h...

  • Page 5: Figure 5

    5 5 figure 5.

  • Page 6: Figure 6

    6 6 configuring the backlight on the rc-112b the backlight on the rc-112b can be configured to one of three different modes: 1) on for 30 seconds when a key is pressed, 2) always on, or 3) always off. 1) to configure the display backlight to turn on when a key is pressed, then back off 30 seconds la...

  • Page 7

    7 7 power up 1. Double check wiring, be sure that thereareno stray wires or wire strands at the connections. 2. It is not necessary to connect the remote system (comm) cable at this time. 3. Connect power to the transformer and system. The display will show all segments for about 5 seconds. 4. Press...

  • Page 8

    8 8 00 address if you are using communications mode 0 or 1, and you are installing more than one thermostat, each must be set to a consecutive address, starting at 1. The default address setting is 1. An address from 1- 127 may be selected. 01 communications mode the thermostat can communicate with ...

  • Page 9

    9 9 03 display options the thermostat can be configured to display the following attributes: 0 celsius am/pm time format programmable 1 fahrenheit am/pm time format programmable 2 celsius 24-hour time format programmable 3 fahrenheit 24-hour time format programmable 4 celsius am/pm time format non-p...

  • Page 10

    1 1 0 0 10 stage 2 differential this item specifies the temperature difference between stage 1 (or low speed) heat pump operation and stage 2 (or high speed) heat pump operation. The default setting of 1 (degree f) is recommended for most applications. If energy efficiency is more important than pre...

  • Page 11

    1 1 1 1 14 clock adjust if the clock on the thermostat is running faster or slower than the actual time, you can have the thermostat automatically compensate up to 29 seconds per day. The thermostat will add or subtract the selected amount of time daily. (1 = “- 29” to 59 = “+ 29” seconds per day; 3...

  • Page 12

    1 1 2 2 quick-reference setup guide this table displays each installer setup item with its default setting. The column labeled "current" can be used to write down the current settings if any changes are made to the default settings. Item number description default current 00 address 1 01 communicati...

  • Page 13

    1 1 3 3 note: do not connect the red comm cable wire to 12v. Figure 7 - hookup to an hai system additional thermostats are connected in parallel. They may be connected in home-run or daisy chain configuration. Remote day/night setback switches the thermostat can be connected to a remote system or re...

  • Page 14

    1 1 4 4 * red and yellow wires are not used. Insulate each using a small piece of tape. Figure 8 - hookup to remote day/night setback switch other systems for connections to personal computers, utility management systems, and other automation systems, refer to connection diagrams provided with perso...

  • Page 15

    1 1 5 5 troubleshooting tips symptom action to take 1. Check power to the thermostat 2. Check wiring diagrams thermostat dead 3. Check thermostat temperature sensor thermostat will not operate with a damaged temperature sensor symptom action to take 1. Check for break in g, w, or y wire 2. Allow min...

  • Page 16

    1 1 6 6 symptom action to take 1. Heat pump is not able to meet load due to cold weather aux heat on too often 2. Thermostat is in em heat mode – set thermostat to heat or auto mode in em heat mode, the auxiliary heat is turned on. Symptom action to take heat pump heats in cool mode & cools in heat ...