Haier 10518181 Installation Manual

Manual is about: Haier Room Air Conditioner Installation Manual

Summary of 10518181

  • Page 1

    No.0010518181 installation manual of room air conditioner read this manual before installation 1.Driver 2.Hacksaw 3.Hole core drill 4.Spanner(17,19 and 26mm) 5.Torque wrench(17mm,22mm,26mm) 6.Pipe cutter 7.Flaring tool 8.Knife 9.Nipper 12.Reamer 10.Gas leakage detector or soap-and-water solution 11....

  • Page 2

    Fixing of outdoor unit indoor unit selection of installation place power source selection of pipe outdoor unit fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally. When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails or wires in c...

  • Page 3

    Indoor unit 1.Fitting of the mounting plate and positioning of the wall hole 2.Making a hole on the wall and fitting the piping hole cover when the mounting plate is first fixed when the mounting plate is fixed side bar and lintel 1.Carry out, based on the neighboring pillars or lintels, a proper le...

  • Page 4

    Indoor unit fixing the indoor unit body [other direction piping] indoor/outdoor electric cable and drain hose must be bound with refrigerant piping by protecting tape. Cut away, with a nipper, the lid for piping according to the piping direction and then bend the pipe according to the position of wa...

  • Page 5

    Indoor unit 1. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. The type of connecting wire is h05/07rn-f or 245iec57(yzw). 2. If the fuse on pc board is broken please change it with the type of t. 3.15a/250v. 3. The wiring me...

  • Page 6

    Outdoor unit 1.Installation of outdoor unit 3.Connection 4.Attaching drain-elbow 2.Connection of pipes install according to to bend a pipe, give the roundness as large as possible not to crush the pipe connecting the pipe of gas side first makes working easier. The max vertical distance between the ...

  • Page 7

    Outdoor unit 5.Purging method: 7 push the air out of the indoor unit and piping as followes: (1) remove the valve cap on 2-way valve in outdoor unit. (2) loosen by 1/2 turn the flare nut of gas pipe, which is conneted to 3-way valve. (3) loosen 2-way valve by 90 o using hexagon wrench, and after app...

  • Page 8

    It becomes high midway. The end is immersed in water. It waves. The gap with the ground is too small less than 5cm there is the bad smell from a ditch 1.Power source installation 2.Cutting and flaring work of piping 3.On drainage check for installation and test run check items for test run the power...