    Packaged unit operation manual ap42nacaaa au42naiaaa (hpu-44h03) ap42nacmaa au42naimca (hpu-42c03) no.0010571223 ion timer on timer off : am pm am pm am pm : timer clock set time time sleep a u t o lo med hi set temp c room temp temp temp swing mode fan speed on off : am temp swing fan on off mode s...

  • Page 2

    Operation content cautions parts indoor unit outdoor unit operation display wireless remote control operation auto cooling operation dry operation heating operation fan operation sleep timer on and timer off air flow adjustment operation hints energy saving cautions for the operation maintenance air...

  • Page 3

    Cautions 1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4

    Cautions 2 for the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight o...

  • Page 5

    Parts 3 1 2 3 4 1 outlet grill 2 operation panel 3 inlet grill 4 air filter 5 remote-controller indoor unit am temp swing fan on off mode sleep set clock timer reset 5 lock 6 7 outdoor unit air inlet 6 7 [at side and rear] air outlet.

  • Page 6

    Parts manual operation ion timer on timer off : am pm am pm am pm : timer clock set time time sleep a u t o low mid high set temp c room temp temp temp swing mode fan speed on off 7 6 5 3 2 9 8 10 1 4 : 4 remote controlled operation power on/off used for unit start and stop. Swing used to set auto f...

  • Page 7

    Operation 5 clock set when unit is started for the first time and after replacing batteries in remote controller, clock should be adjusted as follows: press clock button, "am"or "pm" flashes. Press or to set correct time. Each press will increase or decrease 1min . If the button is kept depressed, t...

  • Page 8

    Am timer clock set time time sleep a u t o low mid high set temp c temp temp swing mode fan speed on off : operation 6 auto manual operation remote-controlled operation 1 3 note: during auto run operation, temp. Setting will not be shown in lcd display, unit will select heating, cooling or fan opera...

  • Page 9

    Operation 7 cooling manual operation am timer clock set time time sleep set temp temp temp swing mode fan speed on off : 2 3 1 5 4 c remote-controlled operation press on/off button unit starts running. The previous status appears on the display (except. Timer, sleep and swing mode) press mode button...

  • Page 10

    Operation 8 dry manual operation remote-controlled operation press on/off button unit starts running. The previous status appears on the display (except. Timer, sleep and swing mode) press mode button. For each press, operation mode changes as follows: select drying operation shows" " dry operation ...

  • Page 11

    Operation 9 heating manual operation remote-controlled operation press on/off button unit starts running. The previous status appears on the display (except. Timer, sleep and swing mode) press mode button. For each press,operation mode changes as follows: select heating operation " " appears and hea...

  • Page 12

    Operation 10 fan manual operation remote-controlled operation press on/off button unit starts running. The previous status appears on the display (except. Timer, sleep and swing mode) press mode button. For each press,operation mode changes as follows: select fan operation shows " ", fan operation s...

  • Page 13

    Operation 11 sleep am timer clock set time time sleep low mid high set temp c temp temp swing mode fan speed on off : remote-controlled operation before sleeping you can press the sleep button. The conditioner will run under comfort sleep mode, and give you a comfort sleep. Usage of the sleep functi...

  • Page 14

    Operation 12 timer on/off operation manual operation remote controlled operation timer operation timer on am am : timer clock set time time sleep low mid high room temp temp temp swing mode fan speed on off : set clock correctly before starting timer operation (refer to page 5) you can let unit star...

  • Page 15

    Operation 13 timer on-off function manual operation remote controlled operation timer on-off (1) after unit start, select your desired operation mode. Operation mode will be displayed on lcd. (2) timer mode selection press timer button to change timer mode. Every time the button is pressed, display ...

  • Page 16

    Operation 14 air flow adjustment swing louvers (vertical louvers) horizontal louvers (adjust by hand) up and down adjust the louvers by hand to proper position. Put louvers at up position in cooling and down position in heating mode. This will be helpful to keep an even room temp. Note: in cooling o...

  • Page 17

    Operation hints 15 unit operation protection devices inside the unit will activate to stop unit operation, when ambient temp. Is extremely low or high. When unit is running under high humidity in cooling or dehumidifying mode, conden- sate might appear at outlet grill. 3-min delay protection fan spe...

  • Page 18

    Energy saving 16 keep proper room temp. Too cold or too warm is no good to your health, and power consumption will be increased as well. Air filter should be periodically cleaned if air filter is clogged: it will cause poor cooling and heating efficiency, higher power consumption and even problem ma...

  • Page 19

    Cautions for the operation 17 use control panel to operate the unit. Don't press buttons unless necessary. Use fuses of the right capacity. Never use iron or copper wires instead. Don't touch moving outlet grills. Keep a smooth air flow to inlet and outlet of both indoor and outdoor unit. To avoid a...

  • Page 20

    Maintenance 18 disconnect power supply don't touch it with wet hand don't wash with hot water or solvent to clean the unit don't use hot water over 40 c, as this may cause damage to air filter. Wipe air filter carefully. Clean it with warm and wet cloth or with neutral detergent, then wipe it dry wi...

  • Page 21

    Maintenance 19 after season maintenance before season maintenance let the unit run in fan mode for half a day in a fine weather to dry completely the unit inside. Turn off the unit and pull out power plug. There might be certain power consumption even if unit is stopped. Clean air filter and indoor ...

  • Page 22

    Trouble shooting 20 followings are not problems sound of water flowings are not problems. Sound of cracking is heard. Smells are generated. During operation, white fog or steam comes out of indoor unit. In cooling operation, unit switches to fan operation. Unit will not restart after stop. Won't sta...

  • Page 23

    When problems occur? 21 before ask for services, please first check your unit against following. Air conditioner won't start. Is power supply switch turned on? Power supply switch is not set at on. Are operation controlls adjusted correctly as specified? Are horizontal louvers at up position (in hea...

  • Page 24

    Indoor & outdoor unit connection 22 power cable length approx 1.5m approx 2m pipe direction left rear right bottom over 10cm over 10cm over 10cm over 10cm over 10cm over 60cm over 15cm over 100cm.

  • Page 25

    Indoor & outdoor unit connection 22 power cable length approx 1.5m approx 2m pipe direction left rear right bottom over 10cm over 10cm over 10cm over 10cm over 10cm over 60cm over 15cm over 100cm.

  • Page 26

    23 tools necessary tools necessary remote controller cement nail drain hose heat-insalution pipe l-shaped metal fall-prevention fitting metal wire clip drain elbow self-tapping scerw rubber pad hexagon wrench wall hole cover piping hole cover dry battery 7 # putty no. Qty shape and description parts...

  • Page 27

    24 installation procedures display of whole unit installation of outdoor unit 190 340 190 580 installation dimension of outdoor unit (mm) try to bring the packed unit to the installation place. When it is inevitable to unpack the unit, be careful not to damage the unit. Wrap it with nylon etc. After...

  • Page 28

    Installation procedures 25 installation of indoor unit selection of installation place place where it is easy to route drainage pipe and outdoor piping. Place away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evenly to every corner of the room. Pla...

  • Page 29

    26 installation of fall-prevention fitting metal: fix the fitting metal to the wall by screws so that there is no clearance between them. With the unit set up vertically, fix the fitting metal to the unit with screws while making an adjustment at the long portion of the hole so that there is no clea...

  • Page 30

    27 2. Piping connection of indoor unit arrangement of piping and drainage pipe after opening inlet grill, you will see a control box as shown in the fig. Remove the cover before working. Cut away, with a hammer or a saw, the lid for piping according to piping direction. Insulation material copper tu...

  • Page 31

    28 3. Piping connection of outdoor unit. Connect the connecting pipe and inlet and outlet liquid pipe according to the piping method. Installation procedures when piping is longer than 5 m, charge additional refrigerant specified in this list. Pipe length refrigerant charge (g) 5m 10m 15m 20m 500 75...

  • Page 32

    29 electric wiring note: electric wiring must be done by qualified person. Use copper wire only, the parameter of connecting cable is h07rn-f4 x 0.75mm 2 . Wiring of indoor unit insert the cable from outside the wall hole where piping already exist. Pull it out from front. Loosen terminal screws and...

  • Page 33

    30 others 1. Power supply air conditioner must use an exclusive line (over 30a) when installation air conditioner in a wet place, try to use a circuit breaker against current leakage. For installation in other places, use circuit breaker as far as possible. Installation inspection and test run: plea...