  • Page 1

    No.*0010571564 after reading this attached manual, please keep it properly. If the user is changed, please do give this manual to him for the sake of safety and in order to use the air conditioner correctly, please read this manual and the operation manual of indoor unit carefully before using 7-10 ...

  • Page 2: Characteristics of Products

    Characteristics of products characteristics of products 1.220~230v normal power, suitable for both commercial use and home use. 2.Free choice of wire control and remote control. 3.Several types of indoor units, free combination of specification. 4.Single outdoor unit, space-saving and cost-saving. 5...

  • Page 3: Safety Precautions

    If still using the unit under this circumstance, the air conditioner may be damaged and may also cause electric shock or fire accidents. When needing repair, please ask the after- sales service work for help. Improper maintenance and repair may cause water leakage, electric shock and fire. If abnorm...

  • Page 4: Name of Parts

    Name of parts 3 1 2 4 repair panel air inlet air outlet air inlet note: do not block the air inlet and air outlet, otherwise the performance of the air conditioner may be lowered. 1 2 3 4 2.

  • Page 5: Installation Procedure

    Installation procedure install indoor unit 1.Choose installation place the chosen installation place should meet the following requirements and get the userís consent. Place air can freely circulate. Place can perform level installation. The condensate water can be drained smoothly. Place where the ...

  • Page 6: Installation Instruction

    Installation instruction the following is the manual mentioned standard accessories, please check them by yourself. Amount 6 name use screw bolt (m10) and screw nut to tightly fix the outdoor unit on its bracket, and keep it level. When install on the wall or roof, fix the bracket firmly and reliabl...

  • Page 7: Installation Instruction

    Installation instruction please perform the fastening of the screw nut according to the specified torque 2. Welding method of pipe (1)the refrigerant pipe should use clean new pipe. When performing work, pay attention to preventing vapor, dust from entering into the pipe. (2)when loosening and faste...

  • Page 8: Installation Instruction

    Installation instruction 4.Air discharging method according to the method of the figure shown, discharge the air in the indoor unit and pipe out. (1)remove the valve cap of little stop valve of the outdoor unit. (2)loosen the thick flare screw nut connected to big stop valve for about 1~1.5 circle. ...

  • Page 9: Electric Wiring

    The creepage breaker must be installed. If not installing creepage breaker may easily cause electric shock. After wiring, please power on the unit to detect electricity leakage. If the power cable is damaged, in order to avoid danger, it must be changed by the manufacturer or its repair center or th...

  • Page 10: Electric Wiring

    Electric wiring power cable (connect through outdoor unit) remove the repair panel of the outdoor unit, loosen the wire holding clamp a, then put the active wire, null wire and grounding wire of power cable through the wire holding clamp a and connect to the relative terminal block. After finishing ...

  • Page 11: Electric Wiring

    Electric wiring note: the pressing method when there is not terminal block connect the wire of the same diameter to the two sides of wire ends. Do not connect the wire of the same diameter to the same side of the wire end. Do not connect the wires of different diameter together. Terminal block of in...

  • Page 12: Electric Wiring

    10 electric wiring 1. Safety checking * **if the joint of pipe leaks? **how about the thermal insulation of the joint of the pipe? **if the electric wire connection of the indoor and outdoor unit is inserted ** firmly in the wiring board? **if the electric wire connection of the indoor and outdoor u...

  • Page 13: Operation and Performance

    Operation and performance 3 minutes delay function if start the unit immediately after its stop, the compressor will operate after 3 minutes have elapsed to protect the unit. The characteristic of heating operation during operation, if the outdoor temperature is too high, the fan motor of outdoor un...

  • Page 14: Troubleshooting

    Troubleshooting trouble code display e3 e5 phenomenon of outdoor unit trouble the trouble of outdoor ambient temperature sensor the trouble of outdoor coil temperature sensor over electric current protection ct wire breaks the flashing time of indicator light on outdoor control panel indoor control ...

  • Page 15: Troubleshooting

    Troubleshooting symptom cause blow out mist or water overflow the fan motor of outdoor unit automatically stop to perform defrosting. * during operation, in operation and shortly after unit stop, there is a sound of water flow; within 2~3 minutes after operation start, sometimes the sound becomes la...

  • Page 16: Pipe System Chart

    Muf fler one-way valve pipe system chart 14 indoor unit outdoor unit 4-way switch valve compressor indoor heat exchanger outdoor heat exchanger hea ting operation cooling operation note: the wiring diagram is pasted inside the unit. Stop valve indoor heat exchanger compressor gas and liquid separato...