  • Page 1

    N o . * please read this manual carefully before using please keep this manual for future use ab212bcbaa 0 0 1 0 5 7 1 5 7 0 haier network air conditioner two by one room air conditioner contents before use name of parts ************* 3-4 safety precautions ********** 5-6 operation instruction fan o...

  • Page 2: Characteristics of Products

    Characteristics of products far distance monitoring there is a pre-set far distance control communication interface on the control panel of indoor unit. After installing the peripheral equipment according to the manual attached with the haier made far distance control detector, the computer manageme...

  • Page 3

    Operation points 1 operation of air conditioner when the ambient humidity is too high, in cooling or dehumidifying mode, there may be water dropped in the air outlet. Far distance monitoring there is a pre-set far distance control communication interface on the control panel of indoor unit. After in...

  • Page 4

    Operation points anti-cold air blowing out defrosting function during heating operation, after starting the unit, the indoor fan motor will not rotate immediately to prevent cold air from blowing out. During heating operation, when frost formed on the heat exchanger of outdoor unit, the air conditio...

  • Page 5

    Connection pipes and electric wire drain hose louver louver air filter (inside of air outlet) (inside of air inlet grille) air inlet grille air outlet name of parts indoor unit wire controller ** ** ** ** ** ** ** ** ** **** auto ** ** ** **/** 3.

  • Page 6

    Name of parts wire controller 14.Network control display used to adjust the time of timer and clock when the wire controller appears abnormal condition, use a sharp-pointed article to press this button to make the wire controller resume normal after cleaning the air inlet, press this button, the uni...

  • Page 7

    When repair is needed, please ask the after-sales service worker for help. Improper repair and maintenance may cause water leakage, electric shock and fire. If finding abnormal phenomenon (e.G. Smell of firing), please cut off the power first, and contact the after-sales service worker for treatment...

  • Page 8

    Safety precautions 6 notice do not use wet hands to operate the air conditioner. Otherwise, it may cause electric shock. Only use the proper specified fuse. Do not use cable or other materials to replace the fuse, otherwise it may cause fire and other trouble. Do not use water to clean air condition...

  • Page 9

    Fan operation about fan operation: fan operation refers the air conditioner does not perform cooling and heating operation, but fan operation. In this mode, the air conditioner cannot perform auot fan operation, and does show the temperature value on the wire controller. Turn on the unit press the o...

  • Page 10

    Operation instruction auto/cooling/dehumidifying/heating operation hints: the wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press on/off button, the air conditioner will work according to the previous working mode. (except for ...

  • Page 11

    Operation instruction swing fixed air sending direction when the auto swing of the air conditioner swings to an appropriate angle, press swing button, the display “ ” on the lcd of the wire controller will disappear, the air sending direction is fixed. When fixing the air sending direction, the louv...

  • Page 12

    Operation instruction sleep operation use of sleep function after turning on the unit, setting the working mode, then press sleep button to make the air conditioner have the previous sleep time (powered on for the first time or after performing sleep is 1h). The sleep symbol will appear. Press time ...

  • Page 13

    Before using timer function, calibrate the clock first (referring to page 4). When you wake up in the morning, before going back to home after work or after going to bed, you can let your air conditioner automatically turn on or turn off. 2.Set of timer mode press the timer button to change the time...

  • Page 14

    Operation instruction timer on-off function cancel timer press the timer button several times until the timer mode display disappears. According to the sequence of timer on & timer off setting, you can realize turning on unit first, then turning off unit. After adjusting time, press set button to co...

  • Page 15

    Users’ attention set proper room temperature not too low or high and make every peop- le in the room feel comfortable. Do not let the cold air blows directly to human body for a long time and do not make the room temperature drop too low. Otherwise, it may cause uncomfortable or bad to your health. ...

  • Page 16

    Notice only after turning off the unit and cutting off the power can the cleaning of the unit be performed. Otherwise, it may cause electric shock or injury. Do not use water to clean the air conditioner. Otherwise, it may cause electric shock the repair can only be performed by the professional wor...

  • Page 17

    Clean the air filter 2. Dismantle the air filter pull the two side handles at the back of the air inlet grille, lift the air filter to dismantle it. 3. Clean notice do not use the hot water over 50* to clean to avoid discoloration or deformation. Do not dry the unit on fire, the filter may be burnt....

  • Page 18

    Clean the air inlet grille 1. Open air inlet grille pull the two handles at the same time, slowly draw them out. (when closing it, the procedure is reversed.) 2. Remove air filter referring to “clean the air filter”. 3. Remove the air inlet grille open the air inlet grille for 45o, the lift it up. 4...

  • Page 19

    Clean the air outlet and casing notice do not use gasoline, benzene, diluent, polish powder or liquid pesticide to clean. Do not use the hot water over 50* to clean to avoid discoloration or deformation. Use soft dry cloth to clean. If cannot remove the dust, use water or neutral detergent. If the l...

  • Page 20

    Before using season 1. Check the following items: if the air inlet and outlet of indoor and outdoor unit are blocked. If the earth wire is proper. If the wire connection is proper. If there is abnormal phenomenon, please ask the after-sale service staffs for help. 2. Cleaning the air filter or air i...

  • Page 21

    Troubleshooting the following phenomena are not troubles symptom cause the unit does not work the unit blows out mist. The unit gives out noise the unit blows out dust the unit gives out smells. Immediately operate the unit after its stop. 3 minutes later, the unit will automatically operate. In coo...

  • Page 22

    When troubles occur before contacting the commissioned repair center for after-sales service, please check your air conditioner according to the following items. Trouble display e3 e5 phenomenon of outdoor unit trouble the trouble of outdoor ambient temperature sensor the trouble of outdoor coil tem...

  • Page 23

    Installation instruction before installing, do read this “safety precautions” carefully to guarantee the proper installation. The below attentive matters are divided into “ warning” and “ note” two parts. When the wrong installation occur, it is very possible death and severe injury and other seriou...

  • Page 24

    Installation instruction notice warning this manual can not include all kinds of conditions, if you have new requirements and questions, please contact with local haier sales center. Before installing the unit, please read this manual carefully. Improper installation may cause accidents and make uni...

  • Page 25

    1. Before installation [before finishing installation, do not throw the attached parts installation needs] confirm the way to move the unit to the installation place. Before moving the unit to the installation place, do not remove their packages. When have to remove the package, use a soft material ...

  • Page 26

    3. Preparation before installation the position relation among ceiling opening and hoisting screws (unit: mm) ceiling opening and the installation of hoisting screw treatment to ceiling about the treatment of dismantling ceiling. In order to prevent the ceiling from vibration, it is very important t...

  • Page 27

    *. Installation of indoor unit gradienter suspending pole hoisting screw suspending bolt (m8 or m10) the fittings should be prepared on site except for m10 flat washer screw cap (m8 or m10) in order to prevent the bolt from breaking off (safety), they must be installed blow the sus pending parts as ...

  • Page 28

    5.Refrigerant pipe [the proper thermal insulation must be treated to gas pipe and liquid pipe. If not, it may cause water leakage.] the outdoor unit is not charged with refrigerant. When connecting the pipes to unit or dismantling the pipes from the unit, do proceed as the figure shown, use spanner ...

  • Page 29

    The installation height of the drainage enhancing pipe should be less than 530mm. The drainage enhancing pipe should be vertical to the unit and no more than 300mm away from the unit. Instruction) *the slant of the accessory drain hose should be within 75mm to make the drain faucet not bear too much...

  • Page 30

    Test of drainage system (a)after finishing the electric work, perform the test to the drainage system. (b)during test, confirm the water flow properly passes the hose and there is no leakage at the joint. (c)if the house is new, perform test before installing ceiling. (d)even if installing in the se...

  • Page 31

    Connect the unit remove the electric box cover (1), draw the wire in the rubber lining, use wire clamp a to clamp it together with other wires, and connect the wire of the relative polarity to the inner power terminal block. After proper connection, press the wire clamp a tight. Bind the seal cushio...

  • Page 32

    Installation procedure install wire controller 1.Remove the upper cover of wire controller the pc board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage pc board. 2.Install wire controller ** drill 2 wall holes according to the position of t...

  • Page 33

    1. Preparation of decorative panel the treatment of decorative panel the decorative panel cannot be put down with the front downwards, cannot lean on the wall and cannot be put on the extruding objects. Do not touch louver or force on it, otherwise the louver may have trouble. (1) dismantle the air ...

  • Page 34

    Notice if fastening the screws improperly, it may cause the trouble as figure 5 shown. The screw should be fastened properly. If after fastening the screw, there still is gap between decorative panel and ceiling, please readjust the height of the indoor unit (referring to figure 6). If the indoor un...

  • Page 35

    (3)the circuit of the decorative panel connect the wire end of the louver motor installed on the decorative panel (referring to figure 7). When installing the air inlet grille, be careful not to wrap the wire of the louver motor. 3.Installation of air inlet grille and corner cover * (1)install the a...

  • Page 36

    Installation procedure connection of pipe 6.Thermal insulation treatment the thermal insulation of connection pipe should be performed at both gas side and liquid side. In cooling, both liquid side and gas side are in low temperature, in order to prevent dew from forming, thermal insulation should b...

  • Page 37

    35 note: the terminal block’s mark at the two ends of the connection wire should be corresponding one by one, otherwise the air conditioner cannot work normally. Installation procedure electric wiring connect wire between indoor & outdoor unit as the wiring diagram show to arrange the connection wir...

  • Page 38

    36 perform test run before installing decorative panel (1)open the stop valve of gas pipe. (2)open the stop valve of liquid pipe. (3)use remote controller to set to cooling operation, press on/off button to start operation. (4)after finishing operation, cut off the general power supply. Perform test...