Haier AB092ACBHA Operation And Installation Manual

Manual is about: CASSETTE AIR CONDITIONER

Summary of AB092ACBHA

  • Page 1

    No.0010572402 b operation & installation manual ab092acbha au092aabha (hbu-09ha03/r1(b)) ab122acbha au122aabha (hbu-12ha03/r1(b)) please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. Cassette air conditioner.

  • Page 2: Contents

    Contents cautions ........................................................................................... Main points of operation................................................................ Name of each part .......................................................................... Safety c...

  • Page 3: Cautions

    Cautions 1 for the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight o...

  • Page 4: Specifications

    2 all electrical repairs must be carried o u t b y q u a l i f i e d e l e c t r i c i a n s . Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air condi...

  • Page 5: Main Points of Operation

    3 main points of operation operation of air conditioner when the environmental humidity is great, water maybe dripped from the air outlet in cooling or drying mode. 3-minute protection function if restart the unit immediately after stopping, the compressor will start only 3 minutes later to protect ...

  • Page 6: Main Points of Operation

    4 main points of operation prevent cool air blowing off in heating mode,the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off. Defrosting function in heating mode, when frost formed on the outdoor heat exchanger, the air conditioner will automatically defr...

  • Page 7: Indoor Unit

    5 indoor unit swing louver (air flow direction can be adjusted by using the swing button on the remote controller) electrical components case air inlet grille air filter (inside of the inlet grille) name of each part outdoor unit air inlet air outlet drain hose connecting piping and electrical wirin...

  • Page 8: Safety Cautions

    6 below are listed four kinds of safety cautions and suggestions: be sure to conform with the following important safety cautions. The safety cautions should be at hand so that they can be checked at any time when needed. If the air conditoner is transferred to the new user, this manual should be as...

  • Page 9: Safety Cautions

    7 warning no goods or nobody is permitted to be placed on or stand on outdoor unit. Donít clean air conditioner with water. Safety cautions the falling of goods and people may cause accidents. Don't operate the air conditioner with damp hands. Otherwise will be shocked. Only use correct type fuse. M...

  • Page 10: Maintenance

    8 maintenance clean the unit turn off the power supply switch do not touch with wet hand. Do not use hot water or volatile liquid the 4 fixed bolts must be loosed as shown in the figure by arrow if they are bolts, the method is that: push the blots inward till to another edge. Generally the fixed bl...

  • Page 11: Trouble Shooting

    9 trouble shooting seasonal reserve operate the unit with fan mode on a fair day for about half a day to dry the inside of the unit well. Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor...

  • Page 12: Trouble Shooting

    10 the followings are not malfuncition hua hua trouble shooting water flowing sound is heard when the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì bi- bi-î or ìgodo-godoî. It is the flowing sound of the...

  • Page 13: Trouble Shooting

    11 on off trouble shooting air does not blow or the fan speed cannot be changed during drying. In dry mode, when room temperature becomes 2 c higher than temperature setting, unit rill run intermittently at lo speed regardless of fan setting during heating,indoor fan is still running even unit is st...

  • Page 14: When Trouble Happens

    12 when trouble happens insufficient cooling or heating the operation controller adjusted as required air filter too dirty ? Horizontal swing louver upward ? (in heat mode) any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling any other heat sources in the...

  • Page 15: Customer Need-to-Know

    13 customer need-to-know customer need-to-know please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual f...

  • Page 16: Installation Tools

    14 a b c d e f installation tools standard accessories 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scrap...

  • Page 17: Installation Procedures

    15 installation of outdoor unit selection of installation place place strong enough to support unit weight, and will not cause vibration and noise. Place where discharged wind and noise do not cause nuisance to the neighbors, and is sufficiently ventilated. Place where is less affected by rain or di...

  • Page 18: Installation Procedudres

    16 1.Selection of installation place (1) place above the ceiling where have enough space to arrange the unit. (2) place where the drainage pipe can be arranged well. (3) place where inlet and outlet air of indoor and outdoor unit will not be blocked. (4) do not expose the unit to the place with heav...

  • Page 19: Installation Procedures

    17 (3) install a suspending bolt to support the unit weight ,anchor bolt should be used in the case of already exists ceiling. Fow new ceiling, use flush-in type bolt, built-in type bolt or parts pretared in the field. Before going on installing, adjust space to ceiling. Installation of indoor unit ...

  • Page 20: Installation Procedures

    18 large size seal pad 4mm below clip 3.Installation of water drainage pipe (1) install water drainage pipe pipe diameter shall be equal or larger than that of connecting pipe (pipe of polythene; size: 25mm; o.D.: 32mm ) drainpipe should be short, with a downward slope at least 1/100 to prevent air ...

  • Page 21: Installation Procedures

    19 4. Installation of ornament panel install ornament panel on indoor unit (1) check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge before install the ornament panel. (2)fas...

  • Page 22: Installation Procedures

    20 piping connection (1) dimension of connecting pipe fit the nut on and fasten (2) the maximum length and drop height of connecting pipe the maximum length is 10m the maximum drop height is 5m. To ensure the efficiency ,pipes shall be as short as possible. Cautions for piping connection do not twis...

  • Page 23: Installation Procedures

    21 detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod anticlockwise until hitting lightly. 6 in case of gas leakage, tighten parts of pipe connection. If leakage stops, then proceed steps. No gas leakage? 5 4 open the valve rod for the 2-way valve to and ang...

  • Page 24: Installation Procedures

    22 1(l) electrical wiring cautions: use copper wire only. Parameters of connectingline : h05rn-f 4g0.75mm 2 parameters of power supply: h07rn-f 3g2.0mm 2 power supply :1ph,220-230v~,50hz, connect from outside. Wiring methods: 1.Wiring method of ring terminal for connecting line which end is a ring,i...

  • Page 25: Check and Test Run

    Correct incorrect a pipe expander other instructions 1.Configuration of power supply air conditioner must use special power supply system (above 20a), and qualified electrician makes wiring and fixing according to wiring regulations specified in national standard. In socket, exactly distinguish eart...

  • Page 26: Malfunction Judgement

    Malfunction code indoor unit led2 malfunction judgement no. Remark indoor unit malfunction outdoor unit malfunction time state indoor unit led1 time state flash 1 2 flash flash flash flash flash flash flash flash flash malfunction cause 1 2 3 6 7 8 14 10 1 2 3 4 5 6 7 8 9 10 power supply led flash 1...