Guide to Operation
After air conditioner operated for a period, dusts were
gradually accumulated on the filter ,and the filter up/down
function can be used to clean the filter.
1.Whether unit start or stop, continuously press FILTER
button 3 seconds,and enter into the filter up/down waiting
status (when unit stops,the yellow TIMER indicator flashes,
filter and clock displayed on the remote controller and no
others.Only the FILTER button and the temperature button
and time button are active).
2.Press temperature button or time button in filter
up/down waiting status, the up/down mechanism makes
the filter to move downward and do not stop until reach
the maximum limit.
3.Press temperature button or time button in filter
up/down waiting status , the up/down mechanism makes
the filter to move upward till near to the surface board and
then automatically adjust to reset (when adjusting to reset,
it will not be controlled by the remote controller till the adju-
stment is finished, and the remote controller can control
again.
4.During moving downward ,press temperature button
or time button, moving stops.
5.During moving downward ,press temperature button
or time button, moving stops.
6.Continuously press FILTER button 3 seconds again to
cancel the filter up/down waiting mode (unit stops, the
yellow timer indicator stops flashing, the filter backs to
the original position , the remote controller backs to off
status and only clock is displayed).
Note:
If the filter does not thoroughly back to the original position,only need to
operate several times repeatedly.