Haier AB182ACACA Operation Manual

Manual is about: CASSETTE AIR CONDITIONER

Summary of AB182ACACA

  • Page 1

    Operation manual no.0010541136 f cassette air conditioner ab182acmca au182afmca (hbu-18cc03) ab182acaca au182afaca (hbu-18hc03) ab182acnaa au182afnaa (hbu-18ca03/r1) ab182acbba au182afbaa (hbu-18hc03/r1) ab184acmaa au184afmca (hbu-18c13) ab182acnba au182afnba (hbu-18cc03/r1).

  • Page 2: Contents

    1 contents cautions ................................................................................. The name of each part and its function ............... Introduction to spare parts .................................. Remote controller operation .................................. Guide to operatio...

  • Page 3: Cautions

    2 cautions disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Cautions

    3 cautions all electrical repairs must be carried o u t b y q u a l i f i e d e l e c t r i c i a n s . Inadequate repairs may result in a major source of danger for the user of the air conditioner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the ...

  • Page 5

    4 the name of each part and its function indoor unit unit indication section (power, timer, run, pump) remote controller signal receiver the signal is received. Back up switch swing louver air blows out from here. Air flow direction is adjusted. Wireless remote controller air inlet grille takes in t...

  • Page 6

    Introduction to spare parts 5 buttons and display of the remote controller. Operation clock mode swing power on/off temp fan sleep set hour reset lock timer used for unit start and stop. Used to set auto fan direction. Used to select auto run, cool,dry,heat and fan operation. Used to set correct tim...

  • Page 7

    Introduction to spare parts 6 hints lo mid hi auto auto buttons and display of the remote controller. Operation dry cool auto swing fan speed sleep clock set timer on timer off lock clock temp. Signal sending fan operation heat when unit is started for the first time and after replacing batteries in...

  • Page 8

    Remote controller operation 7 remote controller's operation when in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the contro...

  • Page 9

    Guide to operation 8 fan operation remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reselecting is needed.(timer on/off needs reselecting) hints (1) unit start (2) select operation mode ...

  • Page 10

    Guide to operation 9 auto run, cool,heat and dry operation use cool in summer. Use heat in winter. Use dry in spring,autumn and in damp climate. (1) unit start (2) select operation mode (3) select temp.Setting press on/off button, unit starts. Previous operation status appears on display.(not timer ...

  • Page 11

    Guide to operation 10 press fan button. For each press, fan speed changes as follows: (4) fan speed selection unit runs at the speed displayed on lcd. In heat mode, warm air will blow out after a short period of time due to cold-draft prevention function. In dry mode, when room temp. Becomes 2 c hig...

  • Page 12

    Guide to operation 11 timer operation hints set clock correctly before starting timer operation(refer to page 6) you can let unit start or stop automatically at following times: before you wake up in the morning, or get back from outside or after you fall asleep at night. Timer on/off (1)after unit ...

  • Page 13

    Guide to operation 12 temp swing fan on off mode sleep set clock timer lock reset o n a m 2 1 6 3 5 o f f p m 4 every time the button is pressed, time increases 10min. If button is kept depressed, time will change quickly. Every time the button is pressed, time decreases 10min. If button is kept dep...

  • Page 14

    Air flow direction adjustment procedure 13 caution adjusting up/down air flow direction up/down direction can be adjusted by using the swing button on the remote controller. Each time pressing this button, the mode changes in the following sequence. Swing no indication (louver stopped) change to the...

  • Page 15: In Heating Mode

    14 at night, before going to bed you can press down the sleep button on the controller and the air-conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. One hour after sleeping operation start, the temp. Is 1 c higher than the setting one. After another hour the t...

  • Page 16

    15 power failure resume (to be applied for a necessary situation): setting method: when the remote controller is on (excluding timer mode and fan mode), press the "sleeping" button on the remote controller 10 times within 5 seconds, and after the buzzer rings 4 times, the air conditioner will enter ...

  • Page 17

    16 for comfortable use clean the air filter periodically. When cooling season is over,clean the air filter. If air filter is colgged: efficiency of air-conditioning is reduced, and it will result in excessive consumption of elec- tric power. It will result in malfunction. Water drop will drip in coo...

  • Page 18

    17 care and maintenance points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. T h i n n e r d o n o t use! B e n z i n e t o o t h p o w d e r cleaning the air filter clean the air filter periodically. Removal cleaning 1. How to open ...

  • Page 19

    18 malfunction? Care and cleaning of the unit clean with soft and dry cloth. If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water. After wiping, clean off the detergent using clean water. Post-season care operate the unit with fan mode on a fair...

  • Page 20

    The followings are not malfunction water flowing sound is heard. When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru "or" gobo gobo". It is the flowing sound of the refrigerant, and it is n...

  • Page 21

    20 warning operation heat pump type warming with the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized. Defrosting operation when a room is warmed with a heat pump type air conditioner, frost acc...

  • Page 22

    21 safety precautions electric work before starting to use the system, read carefully this "safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified as " warning" and " caution". Precau- tions which are shown in the column of " warning" means t...

  • Page 23

    22 cautions for operation warning caution do not install nearby the place where may have leakage of flammable gas. Depending on the place of in- stallation, a circuit breaker may be necessary. Drain pipe should be arranged to provide a positive draining. If the pipe is arranged improperly, furniture...

  • Page 24

    23 safety precautions caution caution the system should never be used for any other purposes than intended such as for preserva- tion of foods, flora and fauna, precision devices or work of art. It could cause deterioration of foods or other problems. Do not handle switches with a wet hand. Combusti...

  • Page 25

    Caution 24 off on do not use the power switch to turn on or off the system. It could cause a fire or water leakage do not touch the exhaust section while the swing louver is operating there is a risk of injury. Do not use such equipment as a water heater,etc. Around the indoor unit or the remote con...