Haier AB182ACBDA Operation Manual

Manual is about: CASSETTE AIR CONDITIONER

Summary of AB182ACBDA

  • Page 1

    Operation manual no.0010571994 cassette air conditioner ab182acbda au182afbaa (hbu-18hd03/r1).

  • Page 2

    1 contents cautions .................................................................................. The name of each part and its function ................ Introduction to spare parts ................................... Guide to operation ....................................................... Ai...

  • Page 3

    2 cautions disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4

    3 cautions all electrical repairs must be carried o u t b y q u a l i f i e d e l e c t r i c i a n s . Inadequate repairs may result in a major source of danger for the user of the air conditioner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the ...

  • Page 5

    Indoor unit back up switch swing louver air blows out from here. Air flow direction is adjusted. Air inlet grille takes in the indoor air. Air filter removes dust or dirt out of the inlet air. (in the air inlet grille) air inlet outdoor unit air outlet compressor(inside of unit) 4 the name of each p...

  • Page 6: Operation

    Operation % introduction to spare parts 5 buttons and display of the wire controller. Cautions: on cooling only unit, heating mode is not available. Note: the above information is the explanation of the displayed information therefore varies with those displayed in actual operation. Clock used to se...

  • Page 7: Operation

    % introduction to spare parts 6 operating lamp buttons and display of the wire controller. Dry cool auto fan speed timer on timer off clock temp. Fan operation heat clock set when unit is started for the first time, clock should be adjusted as follows: press clock button, "am"or "pm" flashes. Press ...

  • Page 8

    1 4 3 2 fan operation enjoy yourself by just a gentle press. (1) unit start (2) select operation mode press on/off button, unit starts. Previous operation status appears on display. (not timer setting) power indicator lights up. Press mode button. For each press, operation mode changes as follows: u...

  • Page 9

    1 5 2 3 4 guide to operation 8 auto run, cool,heat and dry operation use cool in summer. Use heat in winter. Use dry in spring,autumn and in damp climate. (1) unit start (2) select operation mode (3) select temp. Setting press on/off button, unit starts. Previous operation status appears on display ...

  • Page 10

    1 2 4 3 timer operation hints set clock correctly before starting timer operation. You can let unit start or stop automatically at following time: before you wake up in the morning, or get back from outside or after you fall asleep at night. Operation mode will be displayed on lcd. Power indicator l...

  • Page 11

    Reset 1 6 4 2 3 blank on off on off timer on-off operation mode will be displayed on lcd. Power indicator lights up. Every time the button is pressed, display changes as select . (3)time setting for timer on press time button. (5)time setting for timer off to cancel timer mode every time the button ...

  • Page 12

    About 6 hrs 1 hr 1 hr increase 1 c increase 1 c at night, before going to bed you can press down the sleep button on the controller and the air-conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. One hour after sleeping operation start, the temp. Is 1 c higher t...

  • Page 13

    Adjusting up/down air flow direction up/down direction can be adjusted by using the swing button on the remote controller. Each time pressing this button, the mode changes in the following sequence. Swing no indication (louver stopped) change to the airflow mode. Swing louver stopped louver moves in...

  • Page 14

    Remote control: there is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be computerized and contro...

  • Page 15

    14 for comfortable use 43 15 / 26 -7 / -8 24 / 18 c c c c c c c c c c c c c clean the air filter periodically. When cooling season is over,clean the air filter. If air filter is colgged: efficiency of air-conditioning is reduced, and it will result in excessive consumption of elec- tric power. It wi...

  • Page 16

    15 care and maintenance points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. T h i n n e r do not use! B e n z i n e t o o t h p o w d e r cleaning the air filter clean the air filter periodically. Removal cleaning 1. How to open the...

  • Page 17

    16 malfunction? Care and cleaning of the unit clean with soft and dry cloth. If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water. After wiping, clean off the detergent using clean water. Post-season care operate the unit with fan mode on a fair...

  • Page 18

    The followings are not malfunction water flowing sound is heard. When the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru "or" gobo gobo". It is the flowing sound of the refrigerant, and it is n...

  • Page 19

    18 warning operation heat pump type warming with the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of refrigerant to warm the indoor space, is utilized. Defrosting operation when a room is warmed with a heat pump type air conditioner, frost acc...

  • Page 20

    19 safety precautions electric work before starting to use the system, read carefully this "safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified as " warning" and " caution". Precau- tions which are shown in the column of " warning" means t...

  • Page 21

    20 cautions for operation warning caution do not install nearby the place where may have leakage of flammable gas. Depending on the place of in- stallation, a circuit breaker may be necessary. Drain pipe should be arranged to provide a positive draining. If the pipe is arranged improperly, furniture...

  • Page 22

    21 safety precautions caution the system should never be used for any other purposes than intended such as for preserva- tion of foods, flora and fauna, precision devices or work of art. It could cause deterioration of foods or other problems. Do not handle switches with a wet hand. Combustion appar...

  • Page 23

    Caution 22.