Haier AB212XCEAA Operation And Installation Manual

Manual is about: Haier Cassette Type Air Conditioner Operation & Installation Manual

Summary of AB212XCEAA

  • Page 1

    Please read this operation manual before using the air conditioner. No.0010577706 operation & installation manual cassette type air conditioner please keep this manual carefully and safely. Ab212xceaa.

  • Page 2: Contents

    Contents cautions ............................................................................................. Introduction to spare parts................................................................... Maintenance.....................................................................................

  • Page 3: Cautions

    Cautions 1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Cautions

    2 all electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sha...

  • Page 5: Warning!

    3 warning! Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of safety cautions and suggestions. Warning! Caution! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incor...

  • Page 6: Cautions!

    4 cautions! Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.G. The preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may...

  • Page 7: Introduction to Spare Parts

    Introduction to spare parts 5 drain hose swing fender refrigerant pipe cable line earthing line air filter outlet suction grill (located in the suction grill) in cooling operation, to discharge the water from inside the room. Discharge unit (built in) (located in the outlet).

  • Page 8: [Clean Inlet Grill]

    6 3. Dismantle air filter caution! 4. Clean 6. Close inlet grill 7. Press the filter signal return key on the controller. (a) remove dust with vacuum filter. 5. Install air filter (1) put filter into protruding parts at the top of the inlet grill. (2) connect the two pothooks with inlet grill see 2 ...

  • Page 9: Maintenance

    Maintenance 7 3. Take of inlet grill 4. Clean caution! Note when the filter too much dust to spray the special detergent for vent fan or utensils. 5. Install inlet grill 6. Install air filter 7. Close inlet grill [clean outlet and shell] see 3 see "clean air filter" see 1 caution! Don't use gasoline...

  • Page 10: Maintenance

    8 note the inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by technician. In cooling operation, discharging system discharge water in room. 2. 1. Seasonal reserve operate the unit with fan mode on a fair day for about half a day to dry the inside of the unit wel...

  • Page 11: Trouble Shooting

    9 the followings are not malfuncition hua hua trouble shooting water flowing sound is heard when the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì bi- bi-î or ìgodo-godoî. It is the flowing sound of the ...

  • Page 12: Trouble Shooting

    10 **? On off trouble shooting air does not blow or the fan speed cannot be changed during drying. In dry mode, when room temperature becomes 2 c higher than temperature setting, unit rill run intermittently at lo speed regardless of fan setting during heating,indoor fan is still running even unit i...

  • Page 13: When Trouble Happens

    11 when trouble happens insufficient cooling or heating the operation controller adjusted as required air filter too dirty ? Horizontal swing louver upward ? (in heat mode) any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling any other heat sources in the...

  • Page 14: Customer Need-to-Know

    12 customer need-to-know customer need-to-know please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual f...

  • Page 15: Warning !

    13 warning ! Caution ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditioner. Air-c...

  • Page 16: Installation Procedure

    14 unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this manual. Cover pipe with insulation materials in cas...

  • Page 17: Installation Procedure

    15 installation tools 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7. Pipe expander 8. Knife 9. Pincers 10. Leakage detector or soapy water 11. Band tape 12. Scraper 13. Refrigerant oil the instal...

  • Page 18: Installation Procedure

    3. Preparation for the installation (1) position of ceiling opening between unit and suspending bolt. 3 16 (2) cut an opening in ceiling for installation if necessary. (when ceiling already exists.) (3) install a suspending bolt. (use a m10 bolt) to support the unit weight, anchor bolt shall be used...

  • Page 19: Installation Procedure

    17 4. Installation of indoor unit in the case of new ceiling (3) adjust unit to its right position. (refer to preparation for the installation-(1)) (4) check unit's horizontal level. Watert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level using ho...

  • Page 20: Installation Procedure

    6. Installation of water drainage pipe (as for outdoor piping, please refer to installation manual of outdoor unit.) 5. Refrigerant piping outdoor is precharged with refrigerant. Be sure to see the fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to t...

  • Page 21: Installation Procedure

    (2) check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage. After wiring remove cover of control box, short connect "check" terminal of the indoor unit, which is on the uper part of indoor unit pcb. Connect 1ph power t...

  • Page 22: Installation Procedure

    20 as for outdoor unit circuit, please see installation manual of outdoor unit. Note: all electric wires have their own poles, poles must match that on terminal block. 9. Installation of ornament panel 1. Prepare ornament panel handling of ornament panel ornament panel shall not be placed face down ...

  • Page 23: Installation Procedure

    21 (1) 3. Install ornament panel on indoor unit. As shown in fig . 7, match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit. Installation of ornament panel place the holding ring on swing flao motor side teporarily on...

  • Page 24: Installation Procedure

    22 item to the checked pay special care to the following and check after installation unproper installation may cause check is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? I...

  • Page 25: Installation Procedure

    Installation procedure after electric installation,power on them to do electric leakage test. The electric wiring work shall be conducted by qualified electricians according to the installation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring ...

  • Page 26: Installation Procedure

    Wire connection for built-in indoor unit insert from outside the connection wire and signal transmission wire through the wall hole with pipeline already arranged. Pull out the front ends of connection wire and signal wire and make a circle on the signal wire. Connect the connection wire according t...

  • Page 27: Failure Code

    Failure code the remote receiver can indicate the failure code 25 for remote type, flash times 10 1 2 3 4 5 6 7 8 9 11 14 15 16 17 18 19 20 21 22 failure code on wired control ler 08 01 02 4a 49 48 53 47 07 06 0b 4c 05 54 50 0c 4b 4d 32d 54d for central control, failure code 21 01 02 11 12 10 14 22 ...

  • Page 28

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden ,qianwangang road , economic development zone, qingdao ,shandong 266500, p.R.C web site: http://www.Haier.Com.