Haier AB242ACBCA Operation Manual

Manual is about: CASSETTE AIR CONDITIONER

Summary of AB242ACBCA

  • Page 1

    Please read this operation manual before using the air conditioner. No.0010572002 operation manual ab282acbca au282ahbda (hbu-28hd03/r1) cassette air conditioner ab42nacbca au42naibba (hbu-42hd03/r1) ab242acbca au242ahbba (hbu-24he03/r1) ab36nacbca au36naibba (hbu-36hc03/r1).

  • Page 2

    Contents cautions .............................................................................................. Introduction to spare parts ............................................................... Guide to operation ...............................................................................

  • Page 3: Cautions

    Cautions 1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Cautions

    Cautions 4. The wiring method should be in line with the local wiring standard. 5. The power cable and connecting cable are self-provided. The requirement of the power cable: the connecting cable should be h05rn- f 4g 0.75mm. All the cables shall have got the european authentication certificate. 6. ...

  • Page 5: Cautions

    3 cautions warning! Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of safety cautions and suggestions. Warning! Caution! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequenc...

  • Page 6: Cautions

    Cautions 4 cautions! Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.G. The preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these s...

  • Page 7: Cautions

    5 cautions warning ! Caution ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditione...

  • Page 8: Introduction To Spare Parts

    Introduction to spare parts 6 operation auto % s e t room on off mode fan swing temp clock set timer sleep reset filter reset on/off buttons and display of the wire controller. Cautions: on cooling only unit, heating mode is not available. Note: the above information is the explanation of the displa...

  • Page 9: Introduction To Spare Parts

    Introduction to spare parts 7 % operating lamp buttons and display of the wire controller. Dry cool auto fan speed timer on timer off clock temp. Fan operation heat clock set when unit is started for the first time, clock should be adjusted as follows: press clock button, "am"or "pm" flashes. Press ...

  • Page 10: Introduction To Spare Parts

    Introduction to spare parts indoor unit outdoor unit drain hose swing fender refrigerant pipe cable line earthing line air filter outlet suction grill (located in the suction grill) in cooling operation,to discharge the water from inside the room. Discharge unit (built in) (located in the outlet) 8 ...

  • Page 11: Guide To Operation

    9 guide to operation mode fan swing temp clock set timer sleep reset filter reset on/off 1 4 3 2 a m room fan operation enjoy yourself by just a gentle press. (1) unit start (2) select operation mode (3) fan press on/off button, unit starts. Previous operation status appears on display. (not timer s...

  • Page 12: Guide To Operation

    Guide to operation 10 a u t o mode fan swing temp clock set timer sleep reset filter reset on/off 1 5 2 3 4 s e t low mid high auto auto run, cool,heat and dry operation use cool in summer. Use heat in winter. Use dry in spring,autumn and in damp climate. (1) unit start (2) select operation mode (3)...

  • Page 13: Guide To Operation

    Guide to operation 11 o n mode fan swing temp clock set timer sleep reset filter reset on/off a m a m 1 2 4 3 s e t timer operation hints set clock correctly before starting timer operation. You can let unit start or stop automatically at following time: before you wake up in the morning, or get bac...

  • Page 14: Guide To Operation

    Guide to operation 12 o n o f f mode fan swing temp clock set timer sleep reset filter reset on/off p m a m 1 5 6 4 2 3 s e t blank on off on off timer on-off operation mode will be displayed on lcd. Power indicator lights up. Every time the button is pressed, display changes as follows: select . (3...

  • Page 15: Guide To Operation

    Guide to operation 13 at night, before going to bed you can press down the sleep button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. In cooling, dehumidifying mode in heating mode comfortable sleep note: in auto mode, unit w...

  • Page 16: Guide To Operation

    Guide to operation 14 adjusting up/down air flow direction up/down direction can be adjusted by using the swing button on the remote controller. Each time pressing this button, the mode changes in the following sequence. Swing no indication (louver stopped) change to the airflow mode. Swing louver s...

  • Page 17: Guide To Operation

    Guide to operation 15 remote control: there is a telecommunication interface for remote control on the control panel of the indoor unit. After the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector, the air conditioner will be c...

  • Page 18: Maintenance

    Maintenance 16 appropriate room temperature setting don't be too low or too high, to make everybody in the room feel comfortable. Otherwise reduce the efficiency of the air- conditioner. Don't open the doors and windows. Otherwise will consume several or dozens of kwh electricity per day. To use air...

  • Page 19: Maintenance

    Maintenance 17 3. Dismantle air filter caution! Don't wash with water over 50 ,to prevent discoloring or deforming. Don't dry over fire. Filter maybe burn. 4. Clean 6. Close inlet grill 7. Press the filter signal return key on the controller. [ clean air filter ] (a) use vacuum suction or (b) wash w...

  • Page 20: Maintenance

    Maintenance 18 [clean inlet grill] 3. Take of inlet grill open the inlet grill by an angle of 45 , lift up. 4. Clean caution! Don't wash with water over 50 c,to prevent decoloring or deforming. Use soft brush, water and neutrul detergent, then swing off the water. Note when too much dust to spray th...

  • Page 21: Maintenance

    Maintenance 19 [dismantle and install swing plate ] 3. Install swing plate lightly rotate swing plate to insert the ridge at both ends of the outlet into the groove and then screw up. For detailed information consult dealer. Perfect circuit connection. If any abnormal cases, consult dealer. 2. Call ...

  • Page 22: Trouble Shooting

    Trouble shooting 20 the following symptoms are not faults symptom reason conditioner doesn't work when stop machine then continue operation. When press temp setting key and release at once. When power turns on. When humidity too high in the cooling operation (high content of oil or just in room). Wh...