Haier AB242AEEAA Operation Manual

Manual is about: Cassette Type

Summary of AB242AEEAA

  • Page 1

    Please read this operation manual before using the air conditioner. No.0010577963 f operation & installation manual cassette type air conditioner please keep this manual carefully and safely. Ab122acera ab182acera ab242acera ab242aeera ab282aeera ab362acera ab362aeera ab482aeera ab602acera ab122acea...

  • Page 2: Contents

    Contents cautions ........................................................................................... Unit appearance................................................................................ Maintenance......................................................................................

  • Page 3: Cautions

    Cautions 1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Cautions

    2 do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant spurts out and gets into eyes, it may result in se...

  • Page 5: Warning!

    3 warning! Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of safety cautions and suggestions. Warning! Caution! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incor...

  • Page 6: Cautions!

    4 cautions! Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.G. The preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may...

  • Page 7: Warning !

    5 warning ! Caution ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditioner. Air-co...

  • Page 8: Unit Appearance

    Unit appearance 6 ab362acera - ab482aceaa - ab602aceaa ab602acera ab282aeera - ab362aceaa -ab362aeera ab422aeeaa - ab482aeeaa - ab482aeera ab122aceaa - ab122acera - ab182aceaa ab182acera ab242aceaa - ab242acera - ab282aceaa ab242aeeaa - ab242aeera - ab282aeeaa.

  • Page 9: Maintenance

    7 maintenance clean the unit turn off the power supply switch do not touch with wet hand. Do not use hot water or volatile liquid for detailed information consult dealer. Note: for series 122, 182 and ab242aeeaa, ab242aeera, ab282aeeaa, ab282aeera, ab362aceaa, ab362aeera, ab422aeeaa, ab482aeera, ab4...

  • Page 10: Maintenance

    Maintenance 8 for series 602 and ab242aceaa, ab242acera, ab282aceaa, ab362acera, ab482aceaa clean the air filter instructions : 1. Open air inlet grille 2.Dismantle the air filter 3. Clean when not for cleaning, do not dismantle the air filter, otherwise it may cause trouble. When the air conditione...

  • Page 11: Maintenance

    9 maintenance clean the air inlet grille 1. Open air inlet grille 2. Remove air filter 3. Remove the air inlet grille 4. Clean use soft brush, water and neutral detergent to clean, then throw the water off. Instruction when there is too much dust use ventilation fan or directly spray the detergent s...

  • Page 12: Maintenance

    10 note the inner part of indoor unit must be cleaned. Consult dealer, because clean must be done by technician. In cooling operation, discharging system discharge water in room. 2. 1. Seasonal reserve operate the unit with fan mode on a fair day for about half a day to dry the inside of the unit we...

  • Page 13: Trouble Shooting

    11 the followings are not malfuncition hua hua trouble shooting water flowing sound is heard when the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds “ bi- bi-” or “godo-godo”. It is the flowing sound of the...

  • Page 14: Trouble Shooting

    12 **? On off trouble shooting air does not blow or the fan speed cannot be changed during drying. In dry mode, when room temperature becomes 2 c higher than temperature setting, unit rill run intermittently at lo speed regardless of fan setting during heating,indoor fan is still running even unit i...

  • Page 15: When Trouble Happens

    13 when trouble happens insufficient cooling or heating the operation controller adjusted as required air filter too dirty ? Horizontal swing louver upward ? (in heat mode) any obstacle exists at the air inlet or outlet? Door or window left opened ? Insufficient cooling any other heat sources in the...

  • Page 16: When Trouble Happens

    14 when trouble happens error display ( for era series ) resumable if lower than 100 degree for remote type, flash times 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure...

  • Page 17: When Trouble Happens

    15 when trouble happens error display ( for eaa series ) for remote type, flash times 1 2 3 4 5 6 8 9 10 11 12 13 15 17 18 19 20 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure outdoor coil temp. Sensor failure/compressor ...

  • Page 18: Customer Need-to-Know

    16 customer need-to-know customer need-to-know please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual f...

  • Page 19: Installation Procedure

    17 unit shall be grounded. But grounding shall not be connected to gas pipe water pipe, telephone line. Poor grounding will cause electric shock. Be sure to install a leakage breaker to avoid electric shock. Arrange water drainage according to this manual. Cover pipe with insulation materials in cas...

  • Page 20: Installation Procedure

    (1) position of ceiling opening between unit and suspending bolt. (2) ceiling height indoor unit can be installed on ceiling of 2.5-3m in height. (refer to foeld setting and installation manual of ornament panel.) (3) install suspending bolt. Check if the installation place is strong enough to hold ...

  • Page 21: Installation Procedure

    19 (2) cut an opening in ceiling for installation if necessary. (when ceiling already exists.) (3) install a suspending bolt. (use a m10 bolt) to support the unit weight, anchor bolt shall be used in the case of already exists ceiling. For new ceiling, use built-in type bolt or parts prepared in the...

  • Page 22: Installation Procedure

    20 4. Installation of indoor unit in the case of new ceiling (3) adjust unit to its right position. (refer to preparation for the installation-(1)) (4) check unit's horizontal level. Watert pump and flating switch is installed inside indoor unit, check four corners of the unit for its level using ho...

  • Page 23: Installation Procedure

    21 (2) check if water drainage is smooth after installation. 6. Installation of water drainage pipe (as for outdoor piping, please refer to installation manual of outdoor unit.) 5. Refrigerant piping outdoor is precharged with refrigerant. Be sure to see the fig.1, when connecting and removing pipin...

  • Page 24: Installation Procedure

    22 for series 122,182 and ab242aeeaa, ab242aeera, ab282aeeaa, ab282aeera, ab362aeera, ab362aceaa, ab422aeeaa, ab482aeeaa check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and check that the dimension of the ceiling opening is correct. Take off the lever gauge...

  • Page 25: Installation Procedure

    23 method of water charging charge water from air outlet charge water from inspecting hole watering can of plastic pipe should be about 100 mm long 100mm water drainage port for maintenance (drain water from this hole) self-provided stiff pipe maintenance inspecting hole for series ab242aceaa, ab242...

  • Page 26: Installation Procedure

    24 as for outdoor unit circuit, please see installation manual of outdoor unit. Note: all electric wires have their own poles, poles must match that on terminal block. 9. Installation of ornament panel 1. Prepare ornament panel handling of ornament panel ornament panel shall not be placed face down ...

  • Page 27: Installation Procedure

    25 (1) 3. Install ornament panel on indoor unit. As shown in fig.7,match the position of swing flap motor with that of the indoor unit piping hole , so that ormament panel can be placed on to indoor unit. Installation of ornament panel place the holding ring on swing flao motor side teporarily on ho...

  • Page 28: Installation Procedure

    26 item to the checked pay special care to the following and check after installation unproper installation may cause check is indoor unit firmly installed? Is gas leakage check performed? Is unit properly insulated? Is water drainage smooth? Is power voltage meet that stipulated on the nameplate? I...

  • Page 32

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden ,qianwangang road , economic development zone, qingdao ,shandong 266500, p.R.China web site: http://www.Haier.Com.