Haier AC142ACBIA Operation And Installation Manual

Manual is about: CONVERTIBLE TYPE AIR CONDITIONER

Summary of AC142ACBIA

  • Page 1

    Operation & installation manual convertible type air conditioner ac142acbia au142afbia ac182acbia au182afbja no. 0010572896 e please read this operation manual before using the air conditioner. Please keep this manual carefully and safely..

  • Page 2: Contents

    Contents cautions ............................................................................... Safety precautions .................................................................. Features and functions ........................................................... Name of parts.......................

  • Page 3: Cautions

    1 cautions for the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight o...

  • Page 4: Cautions

    Cautions d l k1 temperature and humidity range if the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during cooling and dry modes, if the unit is used under conditions of lower temper...

  • Page 5: Safety Precautions

    Safety precautions warning! If the power supply cord of this air conditioner is damaged, it must be replaced by the manufacturer its authorized service personnel only. Use copper wire only. All the cables shall have got the european authentication certificate. The power supply connects from the outd...

  • Page 6: Features and Functions

    Features and functions automatic operation sleep heat & cool type merely press the on/off button, and the unit will begin automatic operation in any of the heating, cooling and blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room. Cooling type w...

  • Page 7: Name of Parts

    Name of parts fig.1 indoor unit 1 4 6 7 3 fig.2 power oper timer comp emer 2 fig.3 outdoor unit 12 intake grill 13 outlet grill 14 pipe unit 13 12 14 fig.3 1 operating control panel (fig.2) 2 emergency switch 3 remote control signal receiver 4 power indicator lamp (red) 5 operation indicator lamp (g...

  • Page 8: Cleaning and Care

    Cleaning and care caution! Before cleaning the air conditioner ,be sure to turn it off and disconnect the power supply cord. Be sure the intake grill is installed securely. When removing and replacing the air filters, be sure not to touch the heat exchanger, as personal injury may result. Cleaning t...

  • Page 9: Trouble Shooting

    Followings are not problems sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode. In cooling operation, unit switches to blowing operation...

  • Page 10: Trouble Shooting

    Before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating is power supply switch turned on? Power supply switch is not set at on. Is city power supply normal? Is leakage current breaker activated? This is very dangerous, please ...

  • Page 11: Operation Tips

    Malfunction code indoor unit led2 malfunction judgement no. Remark indoor unit malfunction outdoor unit malfunction time state indoor unit led1 time state flash 1 2 flash flash flash flash flash flash flash flash flash malfunction cause 1 2 3 6 7 8 14 10 1 2 3 4 5 6 7 8 9 10 power supply led flash 1...

  • Page 12: Installation

    Installation warning ! Caution ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditioner. Air-conditioner can't be install...

  • Page 13: Installation Tools

    Installation tools standard parts the following installation parts are furnished. Use them as required. 11 mark parts name adhesive tape saddle (l.S) with screws connecting electric cable for indoor and outdoor drain hose heat insulation material piping hole cover putty plastic clamp optional parts ...

  • Page 14: Installation Procedures

    Installation procedures under ceiling 9.52mm dia 15.88mm dia. Outdoor unit indoor unit 2 cm or more ceiling indoor unit 30 cm or more left right 1.5m floor console 30 cm or more 30 cm or more 1.5m 1.5m left right may be difference selecting the mounting position (1)do not install where there is the ...

  • Page 15: Installation Procedures

    Installation procedures 30 cm or more 60 cm or more 40 cm or more 30 cm or more 60 cm or more 2. Outdoor unit (1) if possible, do not install the unit where it will be exposed to direct sunlight.(if necessary, install a blind that does not interfere with the air flow.) (2) install the outdoor unit i...

  • Page 16: Installation Procedures

    Installation procedures open the intake grill and remove the three or four or six screws.(fig. 1) remark: the main unit can be wired before the indoor unit is installed. Select the most appropriate installation order. A. Floor console type 1. Drilling for piping select piping and drain directions.(f...

  • Page 17: Installation Procedures

    Installation procedures select whether the drain hose will be connected to the left or right side.(fig.3) insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener. (fig.6) 2. Installing drain hose (fig. 6) wrap the insulation (drain hose) around the drain hose conne...

  • Page 18: Installation Procedures

    Fig. 15 3. Installing brackets install the brackets with nuts, washers and spring washers.(fig. 15) spring washer special nut bracket 4. Installing indoor unit bracket (right) bracket (left) installation procedures select piping and drain directions. (fig.11) 1. Drilling for piping fig. 14 fig. 13 i...

  • Page 19: Installation Procedures

    Installation procedures select whether the drain hose will be connected to the left or right side.(fig.3) insert the drain hose into the drain pan, then secure the drain hose with a nylon fastener.(fig.6) wrap the insulation (drain hose)around the drain hose connection.(fig.7) be sure to arrange the...

  • Page 20: Installation Procedures

    Installation procedures place where air circulates. Place free from heat radiation from other heat sources. Place where drain water may be discharged. Place where noise and hot air may not disturb the neighbors. Place where there is not heavy snowfall in winter. Place where obstacles do not exist ne...

  • Page 21: Installation Procedures

    Installation procedures if it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. Detach the charge hose from the service port, open 2-way valve and 3-way. Turn the valve rod antic...

  • Page 22: Installation Procedures

    Installation procedures how to connect wiring to the terminals a. For solid core wiring (or f-cable)(fig.24a) (1) cut the wire with a wire cutter or wire-cutting pliers, then strip the insulation to about 25mm of the exposed solid wire. (2) using a screwdriver, remove the terminal screw(s) on the te...

  • Page 23: Installation Procedures

    Installation procedures electrical requirement electric wire size and fuse capacity: table 5 power supply cord (mm 2 ) fuse capacity(a) max min 3.5 3.5 2.5 2.5 20 30 electrical wiring 1. Indoor unit side (1) remove the electric component box. Fig. 26 electric component box fig. 27 electric component...

  • Page 24: Installation Procedures

    Installation procedures electrical wiring (1) the power source capacity must be the sum of the room air conditioner current and the current of other electrical appliances. When the current contracted capacity is insufficient, change the contracted capacity. (2) when the voltage is low and the air co...

  • Page 25: Installation Procedures

    Installation procedures (2) insert the hinges on the bottom of the intake grill into the holes in the base assembly. Then mount the arms to the three areas on the top of the intake grill. Fig. 35 fig. 34 (1) cut the right side of the intake grill. This is only when the pipe exits from the right side...