Haier AC282AFEAA Operation And Installation Manual

Manual is about: CONVERTIBLE TYPE INDOOR UNIT

Summary of AC282AFEAA

  • Page 1

    Operation & installation manual no. 0010577967 a please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. Convertible type air conditioner ac282afeaa ac362afeaa ac482afeaa ac602afeaa ac282afera ac362afera ac522afera.

  • Page 2: Contents

    Contents cautions ........................................................................... Safety precautions ........................................................... Features and functions ................................................... Name of parts .........................................

  • Page 3: Cautions

    Cautions for the purpose of safety, the air conditioner must be properly grounded in accordance with specifications. Always remember to unplug the air conditioner before opening inlet grill. Always grip plug firmly and pull straight out from the outlet. Disposal of the old air conditioner before dis...

  • Page 4: Cautions

    2 cautions temperature and humidity range if the air conditioner is used under higher temperature condition than those listed, the built-in protection circuit may operate to prevent internal circuit damage. Also, during cooling and dry modes, if the unit is used under conditions of lower temperature...

  • Page 5: Safety Precautions

    3 safety precautions warning! Danger! Do not attempt to install this air conditioner by yourself. This unit contains no user-serviceable parts. Always consult authorized service personnel for repairs. When moving, consult authorized service personnel for disconnection and installation of the unit. D...

  • Page 6: Safety Precautions

    4 safety precautions warning! Provide occasional ventilation during use. Do not direct air flow at fire places or heating apparatuses. Do not climb on and place objects on the air conditioner. Do not hang objects from the indoor unit. Do not set flower vases or water containers on top of the air con...

  • Page 7: Features and Functions

    5 features and functions automatic operation sleep heat & cool type merely press the on/off button, and the unit will begin automatic operation in any of the heating, cooling and blow modes as appropriate, in accordance with the thermostat setting and the actual temperature of the room. Cooling type...

  • Page 8: Features and Functions

    6 features and functions vertical air direction adjustment use the air direction adjustment within the ranges shown above. Horizontal air direction adjustment each time the button is pressed, the air direction range will change as follows: press the air flow direction vertical set button. The vertic...

  • Page 9: Features and Functions

    Each time the button is pressed, the air direction range will change as follows: features and functions 7 the swing range of up-down flap is as follow : air direction louvers right/left 1 2 3 4 5 3 2 1 2 4 1 5 4 5 1 2 3 4 5 air flow direction set range of swing 1 2 3 4 5 1 1 2 3 1 to 3 to 3 to 4 to ...

  • Page 10: Name of Parts

    Name of parts 8 1 operating control panel 2 emergency switch 3 power indicator lamp 4 operation indicator lamp 5 timer indicator lamp 6 compressor lamp 7 remote receiver 8 inlet grill ( filter inside ) 9 front panel 4 5 6 1 power oper timer emer 2 comp 3 for series 282, 362, 422, 482, 602 8 9 1 7.

  • Page 11: Cleaning and Care

    9 the following four procedures are for series 282, 362, 422, 482, 602. 1. Pull the filters upward to remove them from the intake grill. 2. Clean the air filter: remove the dust from the filters by vacuum cleaner or washing them. After washing, allow the air filters to dry thoroughly in an area prot...

  • Page 12: Operation Tips

    10 operation tips operation and performance *heating performance *microcomputer-controlled automatic defrosting heat-pump air conditioners heat your entire room by recirculating air throughout the room, with the result that some time may be required after first starting the air conditioner until the...

  • Page 13: Warning !

    11 warning ! Caution ! Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Incorrect installation may cause water leaking, shock and fire hazard. Please call dealer to install the air-conditioner. Air-c...

  • Page 14: Warning

    1. Selecting the mounting position for authorized service personnel only warning warning caution installation of indoor unit 12 be careful not to scratch the room air conditioner when handing it. After installation, explain correct operation to the customer, according to the operating manual. Let th...

  • Page 15: Installation of Indoor Unit

    For half concealed installation (1) install the indoor unit level on a strong wall which is not subject to vibration. Installation of indoor unit 13 (2) the inlet and outlet ports should not be obstructed : the air should be able to blow all over the room. (3) do not install the unit where it will b...

  • Page 16: Installation of Indoor Unit

    Installation procedure install the room air conditioner as follows: connection pipe requirement table 1 m o d e l diameter liquid side gas side maximum length maximum height (between indoor and outdoor) 9.52 mm 19.05mm 50 m 30 m 14 installation of indoor unit 1. Remove the intake grill and side cove...

  • Page 17: Installation of Indoor Unit

    15 installation of indoor unit 3. Drilling the holes and attaching the suapension bolts if using anchor bolts (1) drill holes for anchor bolts at the locations at which you will set the suspension bolts. Note that anchor bolts (to be obtained locally). (2) install the anchor bolts ,then temporarily ...

  • Page 18: Installation of Indoor Unit

    For half-concesled installation in order to check the drainage, be sure to use a level during installation of the indoor unit. If the installation site of the indoor unit is not level, water leskage may occur caution installation of indoor unit ceiling panel wall when installing the indoor unit in a...

  • Page 19: Installation of Indoor Unit

    Installing the coupler heat insulation after checking for gas leaks, insulate by wrapping insulation around the two parts (large and small) of the indoor unit coupling, using the coupler hest insulation. After installling the coupler heat insulation, wrap both ends with vinyl tape so that there is n...

  • Page 20: Installation of Indoor Unit

    18 installation of indoor unit drain piping install the drain pipe with downward gradient (1/50 to 1/100) and so there are no rises or traps in the pipe. Use general hard polyvinyl chloride pipe (vp25)[outside diameter 38 mm.] during installation of the drain pipe,be careful to avoid applying pressu...

  • Page 21: Installation of Indoor Unit

    19 installation of indoor unit (1) install insulation for the drain pipe.(see fig.12 and 13) cut the included insulation material to an appropriate size and adhere it to the pipe. Insulation for drain pipe (to be obtained locally.Length shoud be at least 8mm.) indoor unit(drain port) drain pipe insu...

  • Page 22: Installation of Indoor Unit

    20 installation of indoor unit electrical wiring how to connect wiring to the terminals (1)cut the wire and with a wire cutter or wire-cutting pliers,then strip the insulation to about 15/16"(25mm) of expose the solid wire. (2)using a screwdriver ,remove the terminal screw(s) on the terminal board. ...

  • Page 23: Installation of Indoor Unit

    21 installation of indoor unit caution (1) match the terminal block numbers and connection cord colors with those of the outdoor unit. Erroneous wiring may cause burning of the electric parts. (2) connect the connection cords firmly to the terminal block. Imperfect installation may cause a fire. (3)...

  • Page 24: Installation of Indoor Unit

    22 installation of indoor unit fresh-air intake (1)open up the knockout hole for the fresh-air intake,as shown in fig.16 (if using half-concealed installation ,open up the top knockout hole instead) caution (1)when removing the cabinet(iron plate),be careful not to damage the indoor unit internal pa...

  • Page 25: Warning

    Warning (1) remove the cord clamp. (2) process the end of the connection cords to the dimensions shown in fig.19. (3) connect the end of the connection cord fully into theterminal block. (4) fasten the connection cord with a cord clamp. (5) fasten the end of the connection cord with the screw. (6) t...

  • Page 26: Caution

    Test running 1. Check items (1) indoor unit (1) is operation of each button on the remote control unit normal? (2) does each lamp light normally? (3) do not air flow direction louvers operate normally? (4) is the drain normal? (2) outdoor unit (1) is there any abnormal noise and vibration during ope...

  • Page 27: Trouble Shooting

    25 trouble shooting followings are not problems sound of water flowing is not a problem. Sound of cracking is heard. Smell are generated. During operation, white fog or steam comes out from the indoor unit. No outlet air or fan speed can't be changed in dry mode. In cooling operation, unit switches ...

  • Page 28: Trouble Shooting

    26 before ask for services, please first check your unit against the following. Air conditioner won't start. Poor cooling or heating is power supply switch turned on? Power supply switch is not set at on. Is city power supply normal? Is leakage current breaker activated? This is very dangerous, plea...

  • Page 29: Trouble Shooting

    27 resumable if lower than 100 degree error display ( for era series ) trouble shooting for remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 14 15 16 17 18 19 20 21 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure ou...

  • Page 30: Trouble Shooting

    28 error display ( for eaa series ) trouble shooting for remote type, flash times 1 2 3 4 5 6 7 8 9 10 1 1 12 13 15 17 18 19 20 failure description indoor ambient temp. Sensor failure indoor coil temp. Sensor failure outdoor ambient temp. Sensor failure outdoor coil temp. Sensor failure/compressor d...

  • Page 31

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden ,qianwangang road , economic development zone, qingdao ,shandong 266500, p.R.China web site: http://www.Haier.Com.