Haier AD092AMBHA Operation And Installation Manual

Manual is about: Haier Duct Type Air Conditioner Operation & Installation Manual

Summary of AD092AMBHA

  • Page 1

    Operation & installation manual no. 0010572410 d duct type air conditioning ad122ambha au122aabha (hdu-12ha03/m(r1)(b)) ad092ambha au092aabha (hdu-09ha03/m(r1)(b)).

  • Page 2: Table of Contents

    1 table of contents malfunction 7-8 care and maintenance 9-10 installation manual for outdoor unit 11-14 installation manual for indoor unit 15-20 safety precautions 3-5 parts and functions 6 cautions 2 installation manual for electric wiring 21 installation manual for wire controller 22 check and t...

  • Page 3: Cautions

    Cautions 2 all electrical ropairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by p i e r c i n g o r p e r f o r a t i n g t h e a i...

  • Page 4: Safety Precautions

    Safety precautions before starting to use the system, read carefully this"safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified to " warning" and " caution". Precautions which are shown in the column of " waning" means that an improper handi...

  • Page 5: Safety Precautions

    Safety precautions 4 caution do not wash the air conditioner with water. Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited ...

  • Page 6: Safety  Precautions

    Safety precautions 5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. An extend cord is not recommended, the requirement of the power supply cord is h07rn-f 3g 2.5mm 2 (suitable for installation in european region) 3. If th...

  • Page 7: Parts And Functions

    Parts and functions 6 indoor unit outdoor unit motor(inside) fan(inside) air inlet air outlet drain hose connecting piping and electrical wiring.

  • Page 8: Malfunction

    7 please check the following things about your air conditioner before making a servie call. Malfunction flickering f1 note: this unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it is not required. Content of defect f2 the trouble of...

  • Page 9: Malfunction

    8 malfunction the followings are not malfunction shuru shuru when the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a...

  • Page 10: Care  And  Maintenance

    9 care and maintenance points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. On off thinner do not use! Benzine tooth powder cleaning 1. Clean the air filter by lightly tapping it or with the cleaner. It is more effective to clean the...

  • Page 11: Care  And  Maintenance

    10 "hot keep"is operated in the following cases. When heating is started: in order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to...

  • Page 12

    11 for inspection and maintenance when you change your address or the installation place electric work confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself. Installation place avoid i...

  • Page 13: 1. Accessories

    Installation manual for outdoor unit edging (2) installation where the area with strong winds. Install the unit so that the air outlet section of the unit must not be faced toward wind direction. (1) open space requirement around the unit 2. Selection of the place of installation 1. Accessories "edg...

  • Page 14: 4. Refrigerant Piping

    13 installation manual for outdoor unit (1) outline piping 4. Refrigerant piping (2) piping size (3) limitations for one way piping length and vertical height one way piping length: less than 15m. 90 + 0.5 install the removed flared nuts to the pipes to be connected, then flare the pipes. Precaution...

  • Page 15

    14 installation manual for outdoor unit 7 90 for 6 sec. 4 (5) purging method ( the refrigerant is r407c) if it does not stop gas leakage, discharge whole refrigerants from the serice port. After flaring work again and vacuumize, fill up prescribed refrigerant from the gas cylinder. Detach the charge...

  • Page 16: 1.  Safety Precautions

    15 installation manual for indoor unit 1. Safety precautions warning please read these "safety precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibi...

  • Page 17

    16 installation manual for indoor unit notice all wiring of this installation must comply with national, state and local regulations. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur,...

  • Page 18

    17 installation manual for indoor unit (4) preparation for suspending the unit there should be no obstacles within 250 (a) figure of installation dimension: (unit: mm) when install the duct hidden type indoor unit, the return air box must be designed and installed, as figure3, figure4. The distance ...

  • Page 19

    18 installation manual for indoor unit 28 b c air outlet grille top panel of unit c amplified use screw to fix top panel (figure 6) b air supply passage rivet unit m8 screw nut m8 wide expansion screw bolt (figure 5) a amplified b amplified air supply passage b m8 wide lock washer m8 hoisting screw ...

  • Page 20

    19 installation manual for indoor unit angle steel for support hoisting screw suspending bolt requirements: the indoor side drain hose should be thermal insulated. The parts connected with indoor unit should be thermal insulated. Improper thermal insulation may cause dew-forming phenomenon. The drai...

  • Page 21

    20 installation manual for indoor unit material of connection pipe and thermal insulation foam polyethylene pipe, thickness over 10mm stiff pvc pipe vp 20mm (inside diameter) material of connection pipe material of thermal insulation warning ! Perform with two spanners depenbing on the outdoor unit....

  • Page 22

    21 installation manual for electric wiring 1(l) cautions: use copper wire only.Parameters of connecting line : h05rn-f 4g0.75mm 2 power supply :1ph,220-230v~,50hz, connect from outside. Wiring methods: 1.Wiring method of ring terminal for connecting line which end is a ring,its wiring method as show...

  • Page 23

    22 installation manual for wire controller 1.Remove the upper cover of wire controller the pc board is installed on the back cover of wire controller. When remove the upper cover, pay attention not to damage pc board. 2.Install wire controller ** drill 2 wall holes according to the position of the 2...

  • Page 24: Check and Test Run

    23 check and test run other instruction 1. Set of the air sending of the fan motor before leaving factory, the rotation speed of fan motor has already been set at standard choice. When the indoor unit uses free air sending and not needing to connect with duct, the fan speed of indoor unit is set at ...