Haier AD212BMBAA User Manual

Manual is about: Network Air Conditioner Two by One Room Air Conditioner

Summary of AD212BMBAA

  • Page 1

    Auto, cooling, dehumidifying, heating operation ad212bmbaa haier network air conditioner two by one room air conditioner contents before use to user name of parts safety precautions operation instruction fan operation timer on/off function sleep function timer on-off function maintenance maintenance...

  • Page 2: Characteristics of Products

    Characteristics of products far distance monitoring there is a pre-set far distance control communication interface on the control panel of indoor unit. After installing the peripheral equipment according to the manual attached with the haier made far distance control detector, the computer manageme...

  • Page 3: Operation Points

    1 change of fan speed in cooling mode, the air sending is set at auto, when the indoor temperature is near the set temperature, the fan speed will lower automatically. In heating mode, when room temperature reaches the set temperature, the compressor will stop running, and the fan will change to low...

  • Page 4: Name of Parts

    2 wire controller heat auto set room mode fan swing temp clock set timer sleep reset filter reset on/off indoor unit 1 2 * air outlet * ventilation hole name of parts.

  • Page 5: Name of Parts

    Name of parts wire controller 14.Network control display used to adjust the time of timer and clock w h e n t h e w i r e controller appears abnormal condition, use a sharp-pointed article to press this button to make the w i r e c o n t r o l l e r resume norma after cleaning the air inlet, press t...

  • Page 6: Safety Precautions

    4 safety precautions before starting the unit, please read the following ìsafety precautionsî carefully to guarantee the normal operation of the system. The following lists two kinds of safety precautions ì warningî and ì noticeî. For the items that the improper use may cause death or serious injury...

  • Page 7: Safety Precautions

    Safety precautions 5 notice the system should never be used for any other purposes than intended such as for preservation of food, flora and fauna, precision devices or work of art. Do not put the fire devices in the places, which the a i r f r o m t h e a i r conditioner can directly blow. It may c...

  • Page 8: Operation Instruction

    Operation instruction 3 2 mode fan swing temp clock set timer sleep reset filter reset on/off heat fan operation about fan operation: fan operation refers the air conditioner does not perform cooling and heating operation, but fan operation. In this mode, the air conditioner cannot perform auot fan ...

  • Page 9: Operation Instruction

    2 7 operation instruction auto/cooling/dehumidifying/heating operation hints: the wire controller can memorize the working condition of each time. When start the unit for the second time, just need to press on/off button, the air conditioner will work according to the previous working mode. (except ...

  • Page 10: Timer On/off Function

    Timer on/off function operation instruction set on/off mode fan swing temp clock set timer sleep reset filter reset heat 2 before using timer function, calibrate the clock first (referring to page 3). When you wake up in the morning, before going back to home after work or after going to bed, you ca...

  • Page 11: Operation Instruction

    At this time, the" "will not flash. Off then choose the timer on-off mode. At this time the" "will flash. On 2 9 operation instruction timer on-off function cancel timer press the timer button several times until the timer mode display disappears. According to the sequence of timer on & timer off se...

  • Page 12: Operation Instruction

    10 operation instruction sleep operation use of sleep function after turning on the unit, setting the working mode, then press sleep button to make the air conditioner have the previous sleep time (powered on for the first time or after performing sleep is 1h). The sleep symbol will appear. Press ti...

  • Page 13: Usersí Attention

    Usersí attention set proper room temperature not too low or high and make every people in the room feel comfortable. Do not let the cold air blows directly to human body for a long time and do not make the room temperature drop too low. Otherwise, it may cause uncomfortable or bad to your health. Th...

  • Page 14: Maintenance

    Maintenance 12 notice only after turning off the unit and cutting off the power can the cleaning of the unit be performed. Otherwise, it may cause electric shock or injury. Do not use water to clean the air conditioner. Otherwise, it may cause electric shock the repair can only be performed by the p...

  • Page 15: Maintenance

    Maintenance 13 before using season 1.Check the following items: if the air inlet and outlet of indoor and outdoor unit are blocked. If the earth wire is proper. If the wire connection is proper. If there is abnormal phenomenon, please ask the after-sale service staffs for help. 2.Cleaning the air fi...

  • Page 16: Troubleshooting

    Troubleshooting 14 the following phenomena are not troubles symptom cause hear the sound of water flow when the air conditioner is started; during operation the compressor starts or stops; or when the unit is stopped; sometimes it gives the sound of ìhua, huaî or ìgudu, guduî. This is the sound of t...

  • Page 17: When Troubles Occur

    When troubles occur if after the above checking and treatment, the air conditioner still can not work normally, or find the following phenomena, please stop the operation of the unit and contact the commissioned repair center. The fuse or breaker often opens circuit. During cooling or dehumidifying,...

  • Page 18: When Troubles Occur

    E8 trouble code on wire control type indoor unit the compressor indicator light flashes 1 time in 0.2s/time frequency e4 the compressor indicator light flashes 2 time in 0.2s/time frequency the compressor indicator light flashes 3 time in 0.2s/time frequency the compressor indicator light flashes 4 ...

  • Page 19: Installation Instruction

    17 installation instruction before installing, do read this ìsafety precautionsî carefully to guarantee the proper installation. The below attentive matters are divided into ì warningî and ì noteî two parts. When the wrong installation occur, it is very possible death and severe injury and other ser...

  • Page 20: Installation Instruction

    3 1 4 2 5 big wire clamp 2 6 thermal insulation pipe plastic clamp 8 seal cushion 4 7 8 gasket 11 10 9 18 installation instruction notice warning this manual can not include all kinds of conditions, if you have new requirements and questions, please contact with local haier sales center. Before inst...

  • Page 21: Installation Procedure

    Installation procedure install indoor unit obstacle 19 1. Before installation [before finishing installation, do not throw the attached parts installation needs] confirm the way to move the unit to the installation place. Before moving the unit to the installation place, do not remove their packages...

  • Page 22: Installation Procedure

    Installation procedure install indoor unit (2) if necessary, cut a opening on the ceiling for installation and checking. (in original ceiling circumstance) for the dimension of the ceiling opening, please refer to the above figure. Before installation, finish the preparation work of all the pipes (r...

  • Page 23: Installation Procedure

    Installation procedure install indoor unit 4. Installation of indoor unit fix the indoor unit on the hoisting screw. If necessary, suspend the unit on the crossbeam. Do not use hoisting screw, directly use screw bolt. Note: if the dimension of main parts does not meet the opening of the ceiling, adj...

  • Page 24: Installation Procedure

    Installation procedure install indoor unit 5. Drain hose (a)the drain hose should always have a slant degree (1/50~1/100) to avoid the protruding part or causing water flow bend.* (b) when connecting the drain hose with equipment, be sure not to use too much force to the pipe on one side of the equi...

  • Page 25: Installation Procedure

    Installation procedure install indoor unit (d) when the equipped drain hose used to many units, the position of public pipe should be 100mm lower than the drain hole of any unit. As the figure shown. For this purpose, the thicker pipe should be used. (e) the stiff pvc pipe put indoor side should be ...

  • Page 26: Installation Procedure

    (a)absorb of fresh air (single air supplying) use side air absorbing nozzle or absorb from the air in pipe (b)air discharging use side air discharging nozzle (do use together with air absorbing) (c) perform thermal insulation to the duct to prevent from frosting please consult the after-sales servic...

  • Page 27: Installation Procedure

    Installation procedure install indoor unit recommend to use anti-frost and sound-absorbing duct. (locally bought) the duct installation work should be finished before the fitment of ceiling. The duct must be heat insulated. The specific air-discharging outlet should be installed at the place where t...

  • Page 28: Installation Procedure

    26 installation procedure install wire controller 1.Remove the upper cover of wire controller 2.Install wire controller drill 2 wall holes according to the position of the 2 screw holes on the back cover of wire controller, then hit wood in the wall holes. Put the 2 screw holes on the back cover of ...

  • Page 29: Installation Procedure

    2. Dimension of connection pipe 3. The additional charging amount of refrigerant the additional charging of refrigerant (r407c) should be complied with the installation manual of outdoor unit. It must use measurer to quantificationally charge. The additional charging amount must be complied with the...

  • Page 30: Installation Procedure

    Installation procedure electric wiring 2.The wiring method of straight terminal for those connection wires whose end are not orbicular terminals, their wiring method is: loosen the connecting screw, insert the end of the wire directly into the terminal block, and then tighten screw. Pull the wire ou...

  • Page 31: Installation Procedure

    Installation procedure other instruction and test run 29 other instruction 1.Power supply the air conditioner must use a special power circuit and special air switch. The users should provide special switch, grounding wire by themselves. The wiring should be done by a qualified electrician according...