Haier AD482XMAAA Operation And Installation Manual

Manual is about: DUCT TYPE AIR CONDITIONER

Summary of AD482XMAAA

  • Page 1

    Operation & installation manual no. 0010576258 duct type air conditioner ad482xmaaa.

  • Page 2: Table of Contents

    1 table of contents operation 9-14 malfunction 15-16 care and maintenance 17 for preparation of heating 18 is the unit installed correctly 19 installation manual for wire controller 20-21 installation manual for indoor unit 22-27 installation manual for electric wiring 28 safety precautions 3-5 part...

  • Page 3: Cautions

    Cautions 2 all electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of danger for the user of the air conditoiner. Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes...

  • Page 4: Safety Precautions

    Safety precautions before starting to use the system, read carefully this"safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified to " warning" and " caution". Precautions which are shown in the column of " waning" means that an improper handi...

  • Page 5: Safety Precautions

    4 caution do not wash the air conditioner with water. Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited to place a containe...

  • Page 6: Safety Precautions

    5 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on pc board is broken please change it with the type of t. 3.15a /250v. 4. The wiring method should be in line with the local wiring standard. 1. Applicable ...

  • Page 7: Parts and Functions

    Parts and functions 6 air outlet air inlet duct ad482xmaaa.

  • Page 8: Parts and Functions

    Buttons and display of the wire controller. Cautions: on cooling only unit, heating mode is not available. Note: the above information is the explanation of the displayed information therefore varies with those displayed in actual operation. 7 clock used to set correct time. Timer used to select tim...

  • Page 9: Operation

    8 buttons and display of the wire controller. Clock set when unit is started for the first time, clock should be adjusted as follows: press clock button, "am"or "pm" flashes. Operation operating lamp dry cool auto fan speed sleep timer on timer off clock temp. Fan operation heat remote control parts...

  • Page 10: Operation

    Operation 9 fan operation enjoy yourself by just a gentle press. (1) unit start (2) select operation mode (3) fan press on/off button, unit starts. Previous operation status appears on display. (not timer setting) power indicator lights up. Press mode button. For each press, operation mode changes a...

  • Page 11: Operation

    Auto run, cool,heat and dry operation use cool in summer. Use heat in winter. Use dry in spring,autumn and in damp climate. (1) unit start (2) select operation mode (3) select temp. Setting press on/off button, unit starts. Previous operation status appears on display (not timer setting). Power indi...

  • Page 12: Operation

    11 timer operation hints set clock correctly before starting timer operation. You can let unit start or stop automatically at following time: before you wake up in the morning, or get back from outside or after you fall asleep at night. Operation mode will be displayed on lcd. Power indicator lights...

  • Page 13: Operation

    Blank on off on off 12 timer on-off operation mode will be displayed on lcd. Power indicator lights up. Every time the button is pressed, display changes as follows: select . (3)time setting for timer on press time button. (5)time setting for timer off to cancel timer mode every time the button is p...

  • Page 14: Operation

    Operation about 6 hrs 1 hr 1 hr 13 at night, before going to bed you can press down the sleep button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. In cooling, dehumidifying mode in heating mode setting t sleep run begins slee...

  • Page 15: Operation

    Mark 1 2 3 on inverter have rise and drop swing off fixed frequency no rise and drop not swing 4 the collection temperature of indoor unit the collection temperature of wire controller. Operation 14 power failure compensation (to be applied for a necessary situation) after the power failure compensa...

  • Page 16: Malfunction

    15 please check the following things about your air conditioner before making a servie call. Unit fails to start malfunction on off is the power source switch adjust cut in? Is city supply power in normal? Power stoppage? Isn't the signal receiving section exposed to the direct sunlight or strong il...

  • Page 17: Malfunction

    16 the followings are not malfunction shuru shuru when the air conditioner is started, when the compressor starts or stops during operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru" or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble. W...

  • Page 18: Care and Maintenance

    17 care and maintenance points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatileliquid. On off thinner do not use! Benzine tooth powder cleaning caution do not dry the air filter with fire. Do not run the air conditioner without the air filter....

  • Page 19: Warming Operation

    18 for preparation of heating("hot keep") "hot keep"is operated in the following cases. When heating is started: in order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the ope...

  • Page 20

    19 is the unit installed correctly for inspection and maintenance when you change your address or the installation place electric work confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by your...

  • Page 21

    Installation manual for wire controller 20 1. Remove upper part of wire controller remove upper part of wire controller by press. 2. Install wire controller (1) for exposed installation, use 2 wood screws (accessory). (2) for recessed installation, use 2 wood screws (accessory). Note try as far as p...

  • Page 22

    21 3. Indoor unit wiring connect terminals (a,b,c,d) on lower part of wire controller to terminals (a, b,c,d) on pcb of indoor unit. Hint when make wiring, please keep a distance between wires and power supply cord. Hint tread surface of the terminal well so that shielding may not contact other part...

  • Page 23

    22 installation manual for indoor unit 1. Safety precautions warning please read these "safety precautions" first then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibi...

  • Page 24

    23 notice all wiring of this installation must comply with national, state and local regulations. These instructions do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular problems occur, the matter should be referred to yo...

  • Page 25

    24 (4) preparation for suspending the unit (a) size of hole at ceiling and position of hanging bolts (b) hanger bolts installation use care of the piping direction when the unit is installed. Hanging bolt m10 hole-in anchor hole-in plug insert concrete installation manual for indoor unit dimensions ...

  • Page 27

    26 vp 30 secure the elevation as high as possible (approx. 100 mm) a downhill grade of 1/100 or more drain hose joint for vp 25 (local procurement) 600 (maximum local drain up dimension) right overhead 290~325mm attached drain hose clamp drain piping main unit drain situation can be checked with tra...

  • Page 28

    27 (7) installation work for air outlet ducts calculate the draft and external static pressure and select the length, shape and blowout. A blowout duct 2-spot, 3-spot and 4-spot with 200 type duct are the standard specifications. Determine the number of spots based on following table. Note (1) shiel...

  • Page 29

    28 5. Electric wiring warning danger of bodily injury or death turn off electric power at circuit breaker or power source before making any electric connections. Ground connections must be completed before making line voltage connections. (1) selection of size of power supply and interconnecting wir...