    Duct type air conditioner operation manual and installation manual contents english original instructions no. 0150519050 keep this operation manual for future reference. This product must only be installed or serviced by qualified personnel. Please read this manual carefully before installation. Cau...

  • Page 2

    2 your air conditioning product is marked with this symbol.This means that electrical and electronic products shall not be mixed with unsorted household waste.Do not try to dismantle the system yourself:the dismantling of the air conditioning system,treatment of the refrigerant,of oil and of other p...

  • Page 3: Cautions

    3 cautions disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, wh...

  • Page 4: Safety Precautions

    4 safety precautions before starting to use the system, read carefully this "safety precautions" to ensure a proper operation of the system. Safety precautions described here are classified to " warning" and " caution". Precautions which are shown in the column of " waning" means that an improper ha...

  • Page 5: Safety Precautions

    Do not wash the air conditioner with water. Do not install the system where the air outlet reaches directly the flora and fauna. Make sure to use a fuse of proper electric rating. Do not operate the system while the air outlet grill is removed. It is strictly prohibited to place a container of combu...

  • Page 6: Safety Precautions

    1. Applicable ambient temperature range: the machine is adaptive in following situation 2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person. 3. If the fuse on the indoor pc board is broken please change it with the type of t 3....

  • Page 7: Parts and Functions

    Adh071m1erg adh105m1erg adh125m1erg adh140m1erg adh090m1erg adh105h1erg adh125h1erg adh140h1erg adh160h1erg adh071m3erg 7 parts and functions the pump drain opening electrical components case drain pan evaporator air outlet frame air outlet frame drain pan evaporator the pump drain opening electrica...

  • Page 8: Heating Mode

    "hot keep" function heating mode 8 "hot keep" is operated in the following cases. When heating is started: in order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating operation is started. Wait for approx. 2 to 3 minute, and the operation...

  • Page 9: Care and Maintenance

    Points to observe turn off the power supply switch. Do not touch with wet hand. Do not use hot water or volatile liquid. On off thinner do not use! Benzine tooth powder cleaning the air filter do not dry the air filter with fire. Do not run the air conditioner without the air filter. Pre-season care...

  • Page 10: Troubleshooting

    Please check the following things about your air conditioner before making a service call. When the air conditioner does not operate properly after you have checked the above mentioned items or when the following phenomenon is observed, stop the operation of the air conditioner and contact your sale...

  • Page 11: Troubleshooting

    11 troubleshooting indoor unit trouble shooting malfunction of indoor unit ambient temperature sensor led flash times of indoor pcb wired controller display led4 led3 contents of malfunction possible reasons 0 1 01 sensor disconected,or broken, or at wrong position,or short circuit 0 2 02 malfunctio...

  • Page 12: Accessories

    No. Quantity 1 1 name of parts signal line 3/8" brass nut (liquid side) note 6 1 1 2 3 7 8 9 10 4 1 5/8" brass nut (gas side) 5 coupler heat insulation(gas side) 1 coupler heat insulation(liquid side) drain pipe instructions cable tie(large) cable tie(small) shape 12 connection between the wired rem...

  • Page 13: Precaution For Installation

    Warning please read these "safety precautions" first and then accurately execute the installation work. Though the precautionary points indicated herein are divided under two headings, and , those points which are related to the strong possibility of an installation done in error resulting in death ...

  • Page 14

    For inspection and maintenance when you change your address or the installation place electric work confirm the following items for safe and comfortable use of air conditioner. The installation work is to be burden on the sales dealer, and do not conduct it by yourself. Installation place avoid inst...

  • Page 15: Installation Procedure

    Avoid installation and use at those places listed below. Places exposed to oil splashes or steam (e.G. Kitchens and machine plants). Installation and use at such places incur deteriorations in the performance or corrosion with the heat exchanger or damage in molded synthetic resin parts. Places wher...

  • Page 16: Installation Procedure

    2.Installation of indoor unit fix the indoor unit to the hanger bolts. If required, it is possible to suspend the unit to the beam, etc. Directly by use of the bolts without using the hanger bolts. When the dimensions of main unit and ceiling holes does not match, it can be adjusted with the slot ho...

  • Page 17: Installation Procedure

    Drain pipe caution installing drain pipes good piping 1.5m ~ 2m suspension bolts heat insulation a downhill grade of 1/100 or more (a) drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps. (b) when connecting the drain pipe to unit, pay ...

  • Page 18: Installation Procedure

    Drain pipe (f) the stiff pvc pipe put indoor side should be heat insulated. (e) when constructing drain piping for several units, position the common pipe about 100 mm below the drain outlet of each unit as shown in the sketch. Use vp-30(11/4") or thicker pipe for this purpose. Vp-30 secure the elev...

  • Page 19: Installation Procedure

    Installation work for air outlet ducts calculate the draft and external static pressure and select the length, shape and blowout. A blowout duct 2-spot, 3-spot and 4-spot with 200 type duct are the standard specifications. Note (1) shield the central blowout hole for 2-spot. (2) shield the blowout h...

  • Page 20: Installation Procedure

    Electrical wiring warning danger of bodily injury or death turn off electric power at circuit breaker or power source before making any electric connections. Ground connections must be completed before making line voltage connections. Selection of size of power supply and interconnecting wires preca...

  • Page 24

    Address:haier industrial park,qianwangang road,eco-tech development zone,qingdao 266555,shandong,p.R.C. Contacts: tel +86-532-88936943; fax +86-532-8893-6999 website: www.Haier.Com.