Installation Procedure
Original concrete slab
Use hole hinge, hole plunger or hole bolt.
l
Fasten the nut on the suspension screw and then hang the suspension screw in the T
slot of the suspension part of the unit.
l
Aided with a level meter, adjust level of the unit within 5 mm.
Steel reinforcement structure
Use steel angle or new support
steel angle directly.
Rigid PVC pipe VP31.5mm (internal diameter)
Foamed PE with thickness above 7mm
! Caution
In order to drain water normally, the drain pipe shall be processed as specified in
the installation manual and shall be thermal insulated to avoid dew generation.
Improper hose connection may cause indoor water leakage.
Requirements
The indoor drain pipe shall be thermal insulated.
The connection part between the drain pipe and the indoor unit shall be insulated so as to
prevent dew generation.
The drain pipe shall be slant downwards (greater than 1/100). The middle part shall not be
of S type elbow, otherwise abnormal sound will be produced.
The horizontal length of the drain pipe shall be less than 20 m. In case of long pipe, suppo-
rts shall be provided every 1.5 ñ 2m to prevent wavy form.
Central piping shall be laid out according to the following figure.
Take care not to apply external force onto the drain pipe connection part.
Pipe and insulation material
Pipe
Insulation
VP30
To the largest (app. 10cm)
Down slope above 1/100
S type elbow
1.5m~2m
Support
Insulation
(supplied by the user)
Down slope
above 1/100
Important Points of Safety
Warning
Avoid your body being blown
directly by cold wind for long
period, otherwise your health
may be affected.
Donít extend your fingers or
any other article into the inlet
or outlet during operation of
the machine for touching re-
volving fans may cause human
injury or damage of machine.
If something abnormal (e.g.: burnt
smell etc.) occurs, stop running the
machine, shut down the manual
power switch and contact after
service. Continuous operation in
disorder may cause fire hazard or
electric shock etc.
W
arning for use
W
arning for move and repair
When you have to disassemble
and reinstall the machine, entrust
it to after service. Improper inst-
allation may cause fire hazard,
electric shock or damage of ma-
chine.
Unauthorized alteration or repair
work is strictly forbidden. Impr-
oper alteration or maintenance
may cause fire hazard, electric
shock or water leakage. Repair
work should be entrusted to cert-
ified person of after service.
Attention
Attention points for installation
Ensure the drainage hose work
normally during installation.
Improper installation of drainage
can cause water leakage and
damp articles.
DO NOT install the machine in
place where flammable gas
releases easily to avoid fire
hazard.
Ensure electric leakage breaker
being installed. Electric leakage
breaker MUST be installed,
otherwise electric shock may be
caused.
If the power supply cord is
damaged, call a certified
electrician of the manufacturer
or other maintenance department
to replace it.
!
!
!
!
4
!
!
Hanging bolt
Suspension screw
Support steel angle
Hanging of the indoor unit