Haier AE092FCAHA Instruction Manual

Manual is about: Household MRV Ceiling Concealed Type Room Air Conditioner

Summary of AE092FCAHA

  • Page 1

    Ae092fcaha ae182fcaha 0010570925 a household mrv ceiling concealed type room air conditioner.

  • Page 2

    1.

  • Page 3

    2.

  • Page 4

    3 ae092fcaha ae182fcaha.

  • Page 5: Part Description

    Heating operation indication for adjusting the clock and time for timer operation. Note: this model of air conditioner doesnt provide the air sending direction adjustment function and thus the "lou" key is disengaged while the automatic air direction indication may be displayed. This remote controll...

  • Page 6: Important Points of Safety

    Important points of safety the following four important points of safety and suggestions should be paid great attention: warning: misuse may cause fatal result such as death or serious injury etc. Attention: misuse may cause human injury or damage of machine, in some case fatal results. : content ma...

  • Page 7: Important Points of Safety

    Important points of safety warning l avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. L donít extend your fingers or any other article into the inlet or outlet during operation of the machine for touching re- volving fans may cause human injur...

  • Page 8: Important Points of Safety

    Important points of safety attention attention points for use * ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. * check whether installation bench of the machine is damaged after a long period of use. Machine on damaged ...

  • Page 9: Operating Instructions

    Auto, fan operation operating instructions 2 1 3 4 unit start press the "on/off" key to turn on the unit. The lcd on the remote controller displays the previous operating conditions (excluding previous timer, sleep and louver conditions). The remote controller operation indicator turns on. Am r 2 1 ...

  • Page 10: Operating Instructions

    2 3 1 4 5 r 3 1 2 4 5 operating instructions cool, dry, heat operation recommended operation mode: please use cooling mode in summer and heating mode in winter. Please use dry mode in spring or autumn humid climate. Unit start press the "on/off" key to turn on the unit. The lcd on the remote control...

  • Page 11: Operating Instructions

    4 4. Confirm the setting 12:00 12:00 am 12:00 12:00 operating instructions timer on/off function please adjust the clock before using timer function. You may set the air conditioner automatically turn on or turn off when you wake in the early morning, come off work or after you fall asleep. R 1 4 2 ...

  • Page 12: Operating Instructions

    12:00 12:00 12:00 12:00 * * r 1 4 2 6 3 5 timer on-off operation operating instructions 1. After unit starts, select your desired operation mode. The operation indicator turns on and the operation mode is displayed on the lcd screen. 2. Timer mode selection am timer on timer off timer on blank timer...

  • Page 13: Operating Instructions

    Operating instructions sleep function using sleep function before using this function, the time must be checked and set. After the unit starts, set the operation status, then press "sleep " key. Before going to bed, you can press the "sleep " key on the remote controller and the air condit- ioner wi...

  • Page 14: Troubleshooting

    Troubleshooting the following cases are not troubles. During operation, the air conditioner may sometimes exhibit a sound of "clatter " or "rumble " . This is the common sound of refrigerant flow but not a trouble. A sound of "pi-pa " is generated. Smells are given off. During operation, mist or ste...

  • Page 15: Troubleshooting

    Troubleshooting on off during dry operation, there is no air sent out or fan speed cant be changed. In heat mode, the outdoor unit generates water or steam. This occurs during removal of the frost (in defrosting operation) on the radiator of outdoor unit. Defrost operation in heat mode, the indoor f...

  • Page 16: When Fault Occurs

    When fault occurs poor cooling or heating is the operation controller adjusted as required? Are there any obstructs before the air inlet or outlet? Is there any door or window left open? Poor cooling is there any other heat source in the room? Is there any direct sunlight into the room? Are there to...

  • Page 17: Notice to Users

    Notice to users notice to users l to ensure proper operation of the system, the user shall follow this instruction manual to install the unit. L when handling the air conditioner, please be care not to scratch the case surface. L this instruction manual describes the installation method aided with t...

  • Page 18: Installation Precautions

    Installation precautions 1 7 warning ! Before installing, do read this "safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" warning " and " note" two parts. When the wrong installation occur, it is very possible death and severe injury an...

  • Page 19: Installation Precautions

    Installation precautions this description does not address to all possible cases. For new requirement and query, please consult the regional sales center of haier air conditioner general co., ltd. This instruction manual must be read carefully before beginning of installation, improper ins- tallatio...

  • Page 20: Installation Procedure

    L the power supply shall be connected from the outdoor side. (for models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side the power cord size is 3 x (1.25-1.5)mm 2 , type of yzw). L a separate power circuit shall be supplied and connecte...

  • Page 21: Installation Procedure

    Installation procedure fig 1 choosing the installation location please do not install the unit in places where flammable gases may be leaked. In case that gas is leaked and accumulated around the unit, it may cause dangers of fire etc. The indoor unit shall be installed at locations where cold and h...

  • Page 22: Installation Procedure

    1100 223 installation procedure fig 2 ae182fcaha ae092fcaha installation of indoor unit lthe unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause dangers of unit falling down etc. After selecting the unit installation locati...

  • Page 23: Installation Procedure

    Installation procedure installation of indoor unit l when installing the cassette hind type indoor unit, a specially designed return air bellows shall be installed, as shown in figure 3, figure 4. L the distance between the air duct outlet and the air conditioner air outlet shall not exceed 0.5 m. 2...

  • Page 24: Installation Procedure

    Installation procedure installation of indoor unit installing the suspension screw: use m8 or m10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, m10 size is the only choice). These screws shall be installed as follows with space adapting to air conditio...

  • Page 25: Installation Procedure

    Installation procedure installation of remote controller installation of the remote controller 1. Remove the back cover of the remote controller firstly detach the remote controller back cover at the bottom, then detach at the top. The whole back cover of the remote controller could be removed. Remo...

  • Page 26: Installation Procedure

    25 installation procedure drain pipe ! Caution l in order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements l the indoor drai...

  • Page 27: Installation Procedure

    Installation procedure r efrigerant piping l in installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. L after installation, please verify that there is no refrigerant leakage. The leaked ...

  • Page 28: Installation Procedure

    Installation procedure r efrigerant piping vacuum pumping with a vacuum pump, create vacuum from the stop valve of the outdoor unit. L emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves open all the valves on the outdoor unit. Gas leakage detection check wi...

  • Page 29: Installation Procedure

    Installation procedure celectric wiring ! Warning l the electric wiring work shall be conducted by qualified electricians according to the install- ation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or f...

  • Page 30: Installation Procedure

    Installation procedure electric wiring wiring connection method : (the wiring diagram is attached inside the machine) 1) ring terminal connection method connection method f or ring terminal if there is a ring at the end of the connection wire, the wire connection method is as shown in the right figu...

  • Page 31: Installation Procedure

    Installation procedure field setting field setting field setting the unit number in order to realize central control of the mrv air conditioning system, its necessary to set the indoor unit number (control address). Indoor unit number setting indoor unit number setting switch and confirmation of the...

  • Page 32: List of Troubles

    List of troubles list of displayed troubles on the remote controller trouble description ambient temperature sensor fault indoor unit gas pipe temperature sensor abnormal indoor unit and outdoor unit signal transmission abnormal faulty communication between indoor unit 846 chip and 808 chip indoor u...

  • Page 33: Installation Check

    Installation check and trial operation check if the drain pipe and connection wires are arranged properly. The drain pipe shall be put below. The connection wire shall be put above. Be sure to wrap the drain pipe (especially the indoor part and the part inside the machine) with thermal ins- ulating ...