Haier AE092FCAJA, AE182FCAJA Instruction Manual

Manual is about: CEILING CONCEALED TYPE AIR CONDITIONER INDOOR UNIT

Summary of AE092FCAJA, AE182FCAJA

  • Page 1

    Ae182fcbja 0010572352 household mrv ceiling concealed type room air conditioner ceiling concealed type air conditioner indoor unit ae182fcbja ae092fcaja ae182fcaja 5 8 health and power failure compensation function 14 15-16 17 fault occurs 18 installation precautions 19-20 21-33 34.

  • Page 2

    1.

  • Page 3

    2 21*/15.5* ae092fcbja,ae182fcbja 21*/18* ae092fcaja,ae182fcaja.

  • Page 4: Operation

    3 r407c:ae092fcbja ae182fcbja 4 2 9 7 13 swing new fan s e t l o c k r e s e t 10 1 3 5 6 8 12 ** h e a l t h f a n s p e e d timp mode sleep c l o c k t i m e r on off * a u t o % s e t r o o m o n o f f m o d e f a n t e m p c l o c k s e t t i m e r s l e e p r e s e t fil ter re set o n / o f f ...

  • Page 5: Operation

    * a u t o % s e t r o o m o n o f f m o d e f a n t e m p c l o c k s e t t i m e r s l e e p r e s e t fil ter re set o n / o f f h e a l t h operation 4 1.When using remote controller, first point it to the receiving window of wire controller, and then operate remote controller. A ìtickî tone will...

  • Page 6

    5 note:the wired remote controller is supplied by factory along with the indoor unit,but the remote controller should be purchased separately. Battery loading batteries are fitted as follows: * * * make sure that the remote controller is used within 7 meters from receiver window of the wire controll...

  • Page 7: Important Points of Safety

    Important points of safety the following four important points of safety and suggestions should be paid great attention: warning: misuse may cause fatal result such as death or serious injury etc. Attention: misuse may cause human injury or damage of machine, in some case fatal results. : content ma...

  • Page 8: Important Points of Safety

    Important points of safety warning l avoid your body being blown directly by cold wind for long period, otherwise your health may be affected. L donít extend your fingers or any other article into the inlet or outlet during operation of the machine for touching re- volving fans may cause human injur...

  • Page 9: Important Points of Safety

    8 important points of safety attention attention points for use * ensure ventilation of the room if the machine is used with burning facilities. Deficient ventilation can cause oxygen shortage. * check whether installation bench of the machine is damaged after a long period of use. Machine on damage...

  • Page 10: Operating Instructions

    Operating instructions 9 fan operation enjoy yourself by just a gentle press. (1) unit start (2) select operation mode (3) fan press on/off button, unit starts. Previous operation status appears on display. (not timer setting) power indicator lights up. Press mode button. For each press, operation m...

  • Page 11: Operating Instructions

    Operating instructions 1 0 * a u t o mode fan health temp clock set timer sleep reset filter reset on/off 1 5 2 3 4 s e t s w i n g n e w f a n s e t l o c k r e s e t ** h e a l t h f a n s p e e d t i m p m o d e s l e e p c l o c k t i m e r o n off 5 low mid high auto auto low mid high a u t o a...

  • Page 12: Operating Instructions

    S w i n g n e w f a n s e t l o c k r e s e t ** h e a l t h f a n s p e e d t i m p m o d e s l e e p c l o c k t i m e r o n off operating instructions 11 timer operation hints: set clock correctly before starting timer operation. You can let unit start or stop automatically at following time: bef...

  • Page 13: Operating Instructions

    1 2 * o n o f f mode fan health temp clock set timer sleep reset filter reset on/off p m a m 1 5 6 4 2 3 set blank on off on off timer on-off operation mode will be displayed on lcd. Power indicator lights up. Every time the button is pressed, display changes as follows: select . (3)time setting for...

  • Page 14: Operating Instructions

    Operating instructions about 6 hrs 1 hr 1 hr increase 1 * increase 1 * at night, before going to bed you can press down the sleep button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. One hour after sleeping operation start, t...

  • Page 15: Operating Instructions

    Operating instructions 1 4 s w i n g c o m f o r t s e t l o c k r e s e t l i g h t h e a l t h f a n t i m p m o d e s l e e p c l o c k t i m e r o n o f f * mode fan health temp clock set timer sleep reset filter reset on/off a m s e t o f f 1.How to use the health function (only for units with ...

  • Page 16: Troubleshooting

    Troubleshooting the following cases are not troubles. During operation, the air conditioner may sometimes exhibit a sound of "clatter " or "rumble " . This is the common sound of refrigerant flow but not a trouble. A sound of "pi-pa " is generated. Smells are given off. During operation, mist or ste...

  • Page 17: Troubleshooting

    Troubleshooting on off during dry operation, there is no air sent out or fan speed cant be changed. In heat mode, the outdoor unit generates water or steam. This occurs during removal of the frost (in defrosting operation) on the radiator of outdoor unit. Defrost operation in heat mode, the indoor f...

  • Page 18: When Fault Occurs

    When fault occurs poor cooling or heating is the operation controller adjusted as required? Are there any obstructs before the air inlet or outlet? Is there any door or window left open? Poor cooling is there any other heat source in the room? Is there any direct sunlight into the room? Are there to...

  • Page 19: Notice to Users

    Notice to users notice to users l to ensure proper operation of the system, the user shall follow this instruction manual to install the unit. L when handling the air conditioner, please be care not to scratch the case surface. L this instruction manual describes the installation method aided with t...

  • Page 20: Installation Precautions

    Installation precautions 1 9 warning ! Before installing, do read this "safety precautions" carefully to guarantee the proper installation. The below attentive matters are divided into" ! Warning " and " ! Note" two parts. When the wrong installation occur, it is very possible death and severe injur...

  • Page 21: Installation Precautions

    Installation precautions this description does not address to all possible cases. For new requirement and query, please consult the regional sales center of haier air conditioner general co., ltd. This instruction manual must be read carefully before beginning of installation, improper ins- tallatio...

  • Page 22: Installation Procedure

    L the power supply shall be connected from the outdoor side. (for models with electric-aided heating function, the power supply to the indoor unit shall be connected at the indoor side the power cord size is 3 g(1.0-1.5)mm 2 , type of h05rn-f). L a separate power circuit shall be supplied and connec...

  • Page 23: Installation Procedure

    Installation procedure fig 1 choosing the installation location please do not install the unit in places where flammable gases may be leaked. In case that gas is leaked and accumulated around the unit, it may cause dangers of fire etc. The indoor unit shall be installed at locations where cold and h...

  • Page 24: Installation Procedure

    650 223 installation procedure fig 2 ae092fcaja installation of indoor unit l the unit shall be installed according to the specifications to resist to strong wind and earthquake. Improper installation may cause dangers of unit falling down etc. After selecting the unit installation location, proceed...

  • Page 25: Installation Procedure

    Installation procedure installation of indoor unit l when installing the ceiling concealed type indoor unit, a specially designed return air bellows shall be installed, as shown in figure 3, figure 4. 24 a installing building roof ceiling air supply air outlet duct unit return air return air bellows...

  • Page 26: Installation Procedure

    Installation procedure installation of indoor unit 25 indoor unit flexible joint or static pressure box transitive air duct circular air duct joint of air diffuser air diffuser fig1: duct connected *** mm indoor unit air return shutter rivet air return duct galvanized board glue nail insulating fabr...

  • Page 27: Installation Procedure

    Installation procedure installation of indoor unit installing the suspension screw: use m8 or m10 suspension screws (4, prepared in the field) (when the suspension screw height exceeds 0.9 m, m10 size is the only choice). These screws shall be installed as follows with space adapting to air conditio...

  • Page 28: Installation Procedure

    Installation procedure installation of remote controller upper part of wire use shielede wires for telecommunication between wire controller and indoor unit; indoor unit and outdoor unit. Ground the shield on one side. Otherwise misoperation because of noise may occur. Signal wire is self-provided. ...

  • Page 29: Installation Procedure

    28 installation procedure drain pipe ! Caution l in order to drain water normally, the drain pipe shall be processed as specified in the installation manual and shall be thermal insulated to avoid dew generation. Improper hose connection may cause indoor water leakage. Requirements l the indoor drai...

  • Page 30: Installation Procedure

    Installation procedure r efrigerant piping l in installation, if there is refrigerant gas leakage, please take ventilation measures immediately. The refrigerant gas will generate poisonous gas upon contacting fire. L after installation, please verify that there is no refrigerant leakage. The leaked ...

  • Page 31: Installation Procedure

    Installation procedure r efrigerant piping vacuum pumping with a vacuum pump, create vacuum from the stop valve of the outdoor unit. L emptying with refrigerant sealed in the outdoor unit is absolutely forbidden. Open all valves open all the valves on the outdoor unit. Gas leakage detection check wi...

  • Page 32: Installation Procedure

    Installation procedure electric wiring l the electric wiring work shall be conducted by qualified electricians according to the install- ation instructions. A separate power circuit shall be used. Insufficient power cord amperage or improper wiring will cause danger of electric shock or fire. L duri...

  • Page 33: Installation Procedure

    32 installation procedure electric wiring wiring connection method : (the wiring diagram is attached inside the machine) 1) ring terminal connection method if there is a ring at the end of the connection wire, the wire connection method is as shown in the right figure. Remove the terminal screw and ...

  • Page 34: Installation Procedure

    Installation procedure field setting field setting field setting the unit number in order to realize central control of the mrv air conditioning system, its necessary to set the indoor unit number (control address). Indoor unit number setting indoor unit number setting switch and confirmation of the...

  • Page 35

    Wrap the connection pipe, the drain pipe and the connection wire together with pvc tape..