Haier AF072XCBAA Operation And Installation Manual

Manual is about: Room Air-conditioner indoor units Console Type

Summary of AF072XCBAA

  • Page 1

    Af072xcbaa af092xcbaa af122xcbaa af142xcbaa console type no.0010573520 e cautions..................................................1-4 parts and functions ....... ......... ......... ............ ..5-8 operation... ....... ........ ........ .................... 9-14 m a i n te n a n ce . . . . . . ....

  • Page 2: Cautions

    1 disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which requi...

  • Page 3: Cautions

    2 do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit. Specifications the refrig...

  • Page 4: Cautions

    3 cautions please read the following safety instructions carefully prior to use. The instructions are classified into two levels, warning and caution according to the seriousness of possible risks and damages as follows. Compliance to the instructions are strictly required for safety use. Safety ins...

  • Page 5: Use of Air Conditioner

    Use of air conditioner cautions strict enforcement 4 when abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Connect power supply cord to the outlet completely. After installed, the unit shall be tested for electric leakage. Take care not to damage t...

  • Page 6: Parts and Functions

    5 parts and functions 1 3 4 5 2 1.Outlet 2.Control panel 3.Inlet 4.Filter ( inside ) 5.Outlet remote controller indoor unit fresh high/so timer set filter b a m d health reset lock sleep fan temp on off swing mode clock code light off a u t o heat.

  • Page 7: Parts and Functions

    Parts and functions caution before opening the front grille, be sure to stop the operation and turn the breaker off. Do not touch the metal parts on the inside of the indoor unit, as it may result in injury. On/off button push once to start operation, push once again to stop it. Operation is set to ...

  • Page 8: Parts and Functions

    Parts and functions 7 25 26 21 23 36 fresh high/so timer set filter b a m d health reset lock sleep fan temp on off swing mode clock code light off a u t o 1 2 3 4 6 7 9 10 13 17 15 5 8 18 19 22 34 33 24 27 28 32 31 30 35 20 14 16 remote controller 1.Temp setting button (used to set temperature. Set...

  • Page 9: Parts and Functions

    8 parts and functions clock set displays when healthy run function is set. 22.Temperature display 34.Lock state display 33.Battery energy display notify the user when it is time to change the batteries. 24.Hign/so run display 26.Signal sending display 28.Fresh display 29.Auxiliary electrical heating...

  • Page 10

    9 auto, cool , heat and dry operation 1. Unit start press on/off button,unit starts. Previous operation status appears on lcd (except for timer,sleep and swing setting) 3.Temperature setting then select auto run or select cool operation or select dry operation or select heat operation 2.Select opera...

  • Page 11

    10 fan operation 1.Unit start press on/off button to start your air conditioner. Previous operation status appears on lcd (except for timer, sleep, and swing setting). 2.Select operating mode press mode button. At each press, operation mode changes as follows: 3. Adjust fan speed press fan button. A...

  • Page 12

    11 sleep function before going to bed you can press down the sleep button and the air conditioner will run so as to make you sleep more comfortably. Before using this function, the clock must be set. Use of sleep function after the unit's start, set running mode and then press sleep button once to m...

  • Page 13

    12 every time the button is pressed, time increases 10 minuts. If the button is kept pressed, time changes quickly. Timer on/off function set clock correctly before starting timer operation 1.Unit start after unit start, select your desired operation mode (operation mode will be displayed on lcd) 2....

  • Page 14

    13 timer on-off function set clock correctly before starting timer operation 1.Unit start after unit start, select your desired operation mode (operation mode will be displayed on lcd) 2.Timer mode selection press timer button on the remote controller to change timer mode. Every time the button is p...

  • Page 15: Operation Hints

    14 operation hints power failure resume (please set and apply as necessary) with setting of power failure resume, if sudden power failure occurs, the unit will resume original operation when power is supplied again. Used than setting method: with on of remote controller (except timer and fan),repeat...

  • Page 16: Maintenance

    Maintenance maintenance at the end of application season on a fine day, unit shall be started and operate in fan mode for about half a day until the inside of the unit becomes thoroughly dry. Turn off the unit operation switch and power on/off. Otherwise,there will be some electricity consumption ev...

  • Page 17: Trouble Shooting

    Is the air filter dirty? Normally it should be cleaned every 15 days. Are there any obstacles before inlet and outlet? Is temperature set correctly? Are there some doors or windows left open? Is there any direct sunlight through the window during the cooling operation?(use curtain) are th ere too mu...

  • Page 18

    17 installation manual of room air conditioner place where it is easy to route drainage pipe and outdoor piping. Place ,away from heat source and with less direct sunlight. Place where cool and warm air could be delivered evently to every corner of the room. Place near power supply socket.Leave enou...

  • Page 19: Fixing of The Unit

    Installation manual of room air conditioner 18 fixing of the unit 1. Position of the wall hole wall hole should be decided according to installation place and piping direction.(refer to installation drawings). 2. Making a wall hole drill a hole of 120x70mm dia. With a little slope towards outside. 3...

  • Page 20

    Installation manual of room air conditioner 19 piping connection of the indoor unit 1. Arrangement of piping and drainage pipe after opening inlet grill,you will see a control box. Remove the cover before working. Cut away, with a hammer or a saw, the lid for piping according to piping direction. Ac...

  • Page 21

    20 installation manual of room air conditioner electric wiring : when connecting indoor and outdoor wire, check the number on indoor and outdoor terminal blocks. Terminals of same number and same color shall be connected by the same wire. Incorrect wiring may damage air conditioner's control or caus...

  • Page 22

    21 2.Piping cutting and flaring be sure to carry out deburring after cutting with a pipe cutter. Insert flaring tool to make a flare. Installation inspection and test run: please operate unit according to this manual. Items to be checked during test run. Please made a '' '' in '' '' are there any ga...

  • Page 23

    22 resumable failures are marked with " ", the others are not resumable failures. Resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds. But the other failure code will disappear only after the unit starts up once again. W...