Haier AS072AZBDA Operation Manual

Other manuals for AS072AZBDA: Operation Manual, Operation Manual, Operation Manual
Manual is about: Split Type Room Air Conditioner

Summary of AS072AZBDA

  • Page 1

    As182atnda au182afnba (hsu-18cw03/r1) as162atnca au162afnaa (hsu-16cw03/r1) as072azbda au072abbaa (hsu-07hw03/r1) as072aznda au072abnaa (hsu-07cw03/r1).

  • Page 2

    Contents cautions parts and functions operation maintenance trouble shooting 1-2 3-6 7-14 15-17 18.

  • Page 3

    Cautions disposal of the old air conditioner before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, whic...

  • Page 4

    Cautions always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on the power cord. Always grip plug firmly and pull straight out from the outlet. All electrical repairs must be carried out by qualified electricians. Inadequate repairs m...

  • Page 5: Indoor Unit

    Parts and functions indoor unit as182atnda au182afnba (hsu-18cw03/r1) as162atnca au162afnaa (hsu-16cw03/r1) as072azbda au072abbaa (hsu-07hw03/r1) as072aznda au072abnaa (hsu-07cw03/r1) power operation mode indicator lights up when timer operation is selected. Lights up during compressor running. Inle...

  • Page 6

    Au182afnba (hsu-18cw03/r1) au162afnaa (hsu-16cw03/r1) au072abbaa (hsu-07hw03/r1) au072abnaa (hsu-07cw03/r1) for models: for models: 14 power failure resume (to be applied for a necessary situation): setting method: when the remote controller is on (excluding timer mode and fan mode), press the " sle...

  • Page 7

    On off temp swing mode clock sleep set lock reset timer fan off on auto am pm am pm am pm parts and functions buttons and display of the remote power temp. Fa used to set auto fan used to set correct used to set correct time used to select timer on, timer off, used to lock buttons used to set clock ...

  • Page 8

    On off temp swing mode clock sleep set lock reset timer fan off on auto am pm am pm am pm parts and functions buttons and display of the remote operation hints aut aut dr aut fan clock temp fan hea when unit is started for the first time and after replacing batteries in remote controller, clock shou...

  • Page 10: Auto Run, Fan Operation

    Unit will run in selected mode. Stop display at " " auto or " " fan. Operation enjoy yourself by just a gentle press. (1) unit start (2) select operation mode (3) fan (4) unit stop aut aut aut dr hea fa press on/off button, unit starts. Previous operation status appears on display. (not timer settin...

  • Page 11

    Operation aut dr hea fa cool aut aut lo med hi (1) unit start (2) select operation mode (3) select temp.Setting press mode button. For each press, operation unit will run in operation mode displayed on lcd. Press fan button. For each press, fan speed changes hints (4) fan speed selection unit will s...

  • Page 12

    After operation mode is selected, vertical flap will open automatically according to the mode. Referring to the fig. Operation when humidity is high, condensate water might occur at air outlet if all horizontal louvers are adjusted to left or right. Unit won't restart until 3 minutes have elapsed, d...

  • Page 13

    Operation timer operation hints set clock correctly before starting timer operation(referring to page 6) you can let unit start or stop automatically at following times: before you wake up in the timer on/off (2)timer mode selection press timer button to change timer mode. Every time the button is p...

  • Page 14

    Operation timer on-off (1)after unit start, select your desired operation mode operation mode will be displayed on lcd. Power indicator on indoor unit lights up. (2) press timer button to change timer mode. Every time the button is pressed, display changes as follows: select timer on-off. "on" will ...

  • Page 15

    Operation emergency carry out this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, a " pi " sound starts once, which means the start of this operation. In this operation, it is not possible to change the settings of temperature and air ...

  • Page 16

    Operation in cool mode in heat mode approx. 6 temp. Unit stop temp. Unit stop approx. 3 note: in auto mode, unit will run in sleep function according to operation mode. In fan mode, comfortable sleep is not available. Fig.1 fig.2 comfortable sleep before going to bed at night, you can simply press t...

  • Page 17

    Maintenance cut off power supply before cleaning wipe unit casing with soft cloth. In case of heavy stain, clean it with neutral detergent. Squeeze water in the cloth, wipe off the detergent on unit cleaning of unit casing cleaning of remote controller cleaning of air filter don't use water to wash ...

  • Page 18

    Maintenance.

  • Page 19

    Maintenance proper room closing of doors and windows during operation. Effective use of the never fail to observe the do not block the inlet or outlet. Do not use for other do not pull power plug. Once every avoid time- wasteful better use of air conditioner cleaning of the air filter. Proper temper...

  • Page 20

    Trouble shooting before asking for service, check the following first. Cause or check normal performanc e smells are mist or steam are blown multiple check is power plug inserted? Is there a power failure? Is fuse blown out? Poor phenomenon when unit is stopped, it won't restart immediately until 3 ...