    Room air conditioner outdoor unit before using the air conditioner,please read this manual carefully. Please keep this manual properly for future use. Contents name of parts----------------------1 safety cautions------------------2-3 installation procedure---------4-13 installation instructions no.0...

  • Page 2: Name of Parts

    Name of parts 1 air inlet air outlet (inside of unit) compressor au36naieaa au362aieaa au48naieaa au60naieaa au242ageaa au122aeeaa au182aeeaa air inlet air outlet (inside of unit) compressor air inlet air outlet (inside of unit) compressor air inlet air outlet (inside of unit) compressor au282aheaa ...

  • Page 3: Safety Cautions

    Below are listed three kinds of safety cautions and suggestions. Warning! Caution! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences. Incorrect operations may result in severe consequences of death or serious injuries. Instructions: these in...

  • Page 4: Safety Cautions

    Air-conditioner can't be installed in the environment with inflammable gases because the inflammable gases near to air-conditioner may cause fire hazard. Connect earthing wire. Use discharge pipe correctly to ensure efficient discharge. Earthing wire should not be con- nected to the gas pipe, water ...

  • Page 5: Installation Procedure

    Note : (1). Fix the parts with screws (2).Don't intake the strong wind directly to the outlet air-flow hole. (3).A one meter distance should be kept from the unit top (4).Don't block the surroundings of the unit with sundries installation procedure 2. Selection of the place of installation 1. Access...

  • Page 6: Installation Procedure

    (a) concrete foundation (b) foundation anchor (b) foundation anchor (a) concrete foundation (a) concrete foundation (b) foundation anchor (a) concrete foundation (b) foundation anchor installation of outdoor unit 5 installation procedure 3. Installation of outdoor unit fix the unit in a proper way a...

  • Page 7: Installation Procedure

    (2) installation sketch of outdoor unit 180 447 180 648 410 installation of outdoor unit 6 installation procedure au122aeeaa au182aeeaa au282aheaa au28naheaa au242ageaa 730 630 308 335 power wiring terminal power wiring distribution hole 860 power wiring terminal power wiring distribution hole 25 78...

  • Page 8: 4. Refrigerant Piping

    (1) outline piping 4. Refrigerant piping installation of outdoor unit 7 580 340 380 installation procedure outdoor unit 3-way stop valve gas pipe liquid pipe flare connection indoor unit flare connection 3-way stop valve outdoor unit 3-way stop valve gas pipe liquid pipe flare connection indoor unit...

  • Page 9: Installation Procedure

    (2) piping size gas pipe 15.88x1.0mm install the removed flare nuts to the pipes to be connected, then flare the pipes. Liquid pipe gas pipe 9.52x0.8mm 19.05x1.0mm liquid pipe 9.52x0.8mm (3) limitations for one way piping length and vertical height difference. Forced fastening without centering may ...

  • Page 10: 5. Air Discharging Method

    In the first to third test steps, if the pressure drops, check the leakage in each joint use sense of hearing, feeling and soap water, etc. Methods to find the leaking point. After confirming the leaking point, welding it again or tighten the nut tightly again. Checking the leaking point first step:...

  • Page 11: Installation Procedure

    It shall use the vacuum p ump of (lower than -755mmhg)high vacuum degree and large air discharging (over 40l/min). The vacuumizing time depends on the length of the connecting pipe, generally is 1~2 hours. When vacuumizing, it shall be confirmed both gas and liquid side valves are closed. If after 2...

  • Page 12: 5. Electric Wiring

    5. Electric wiring danger of bodily injury or death turn off electric power at circuit breaker or power source before making any electric connections. Ground connections must be completed before making line voltage connections. (1) selection of size of power supply and interconnecting wires. Precaut...

  • Page 13: Installation Procedure

    Electric wiring 12 (3) wiring procedure 1) remove set screws on the side before taking off the front panel toward the direction shown in figure. 2) connect wires to the terminal block correctly and fix the wires with a wire clamp equipped nearby the terminal block. 3) route the wires in a proper way...

  • Page 14: 6.  Test Run

    13 electric wiring 6. Test run caution this unit will be started instantly without "on" operation when electric power is supplied.Be sure to execute "off" operation before electric power is disconnected for servicing. This unit has a function of automatic restart system after recovering power stoppa...

  • Page 16

    Haier group qingdao haier air conditioner electric co., ltd. Address: haier garden, qianwangang road, economic development zone, qingdao, shandong 266500, p.R.China web site: http://www.Haier.Com.