  • Page 1

    1 haier household electrical dishwasher service manual part# dw-8888-02 haier america trading, llc www.Haieramerica.Com.

  • Page 2

    Table of contents page working principles 3 control panel 4 main technical data 4 electrical circuit diagram 5 wiring technology 5 troubleshooting and maintenance 9 resistance measurements and troubleshooting codes 14.

  • Page 4

    4 the cycle sequence is as follows: power on program selection water intake washing draining rinsing draining excess heat drying control panel main technical data type contents esd200 name household dishwasher power supply ac 110-120v/60hz power pump: 150, heater: 1300w, maximum: 1460w washing mode ...

  • Page 5

    5 electrical circuit diagram wiring technology 1 components wiring specification serial no. Name of components wiring diagrammatic drawing remarks 1 water overflow switch three wire cannot be interchanged.

  • Page 6

    6 2 drain pump two wires can be interchanged 3 door switch the two wires can be interchanged 4 heater the two wires can be interchanged 5 thermo limiter the two wire can be interchanged 6 power supply indicator the two can be interchanged..

  • Page 7

    7 7 transformer the wire can not be interchanged 8 detergent dispenser the wire can interchanged 9 control panel all wires can not be interchanged 10 power supply switch all wires can not be interchanged.

  • Page 8

    8 11 washing pump the three wires can be interchanged 12 water intake supply solenoid valve the two wires cannot be interchanged 13 water level switch the three wires cannot be interchanged.

  • Page 9

    9 14 half load value the two wires can be interchanged 15 wind motor the two wires can be interchanged troubleshooting and maintenance • door switch trouble phenomenon: the dishwasher does not work, the post&pan light is flashing check: whether door is closed close the door open the door and check i...

  • Page 10

    10 y y n y n y cable or program controller is broken • water supply phenomenon: water level cannot reach the required location, the three lights of post & pan, normal, light wash is flashing. Check: whether is flowing in the hose turn on the stopcock whether the stopcock is turned on whether solenoi...

  • Page 11

    11 y n n y y n n • water supply trouble phenomenon: water cannot be drained, the three lights of pots & pan, light wash, rinse & hold are flashing. Check: whether drained whether drain pump circuit is pump is working is electrified damaged drain pump is broken whether pipeline repair is ok pipeline ...

  • Page 12

    12 program controller check the change the is broke water level switch water level switch program controller is broken • heating trouble phenomenon: water cannot be heated check: whether socket connector connect it well is well connected whether thermo limiter is ok change thermo limiter whether hea...

  • Page 13

    13 whether socket connector connect it perfectly is connected perfectly measure whether power change the power supply switch is ok supply switch power supply indicator or circuit is broken advantages of this product series compared to other domestic like products. A) this product has cleaning rate o...

  • Page 14

    14 esd service information 1. Resistance measurements component resistance convection dry fan motor 32Ω dispenser door solenoid 295Ω fill valve solenoid 961Ω heating element 12-15Ω pump motor 30Ω temperature sensor approximately 1100Ω @ 70º f upper wash valve 1061Ω wash motor – single direction star...