Haier H2SM- - annexe 11 Operation Manual

Summary of H2SM- - annexe 11

  • Page 1

    Please read this operation manual before using the air conditioner. Split type room air conditioner operation manual 00105 h2sm-(9+9)hea03/r2 h2sm-(9+12)hea03/r2.

  • Page 2

    Ce tutti i prodotti sono conformi alle seguenti normative europee: - direttiva 73/23/eec basso voltaggio - direttiva 2006/95/ec basso voltaggio - direttiva 89/336/eec compatibilità elettromagnetica - direttiva 2004/108/ec compatibilità elettromagnetica rohs il prodotto è conforme alla normativa 2002...

  • Page 3

    Haier industrial park, no.1 haier road, qingdao, p.R.China ce todos los productos están en conformidad con las siguientes normativas europeas: - bajo voltaje directiva 73/23/eec - bajo voltaje directiva 2006/95/ec - compatibilidad electromagnética 89/336/eec - compatibilidad electromagnética 2004/10...

  • Page 4: R410A

    Questo prodotto contiene gas fluorurati ad effetto serra inclusi nel protocollo di kyoto. Non liberare tali gas nell’atmosfera. Tipo di refrigerante: r410a valore gwp*: 1975 * gwp = potenziale di riscaldamento globale compilare con inchiostro indelebile, • 1 la carica di refrigerante di fabbrica del...

  • Page 5: R410A

    Haier industrial park, no.1 haier road, qingdao, p.R.China 1 1+2= kg r410a 2 kg 2= 1= b c d f e kg contains fluorinated greenhouse gases covered by the kyoto protocol a este producto contiene los gases fluorados de efecto invernadora regulados por el protocolo de kioto. No vierta gases a la atmósfer...

  • Page 6

    Before disposing an old air conditioner that goes out of use, please make sure it's inop- erative and safe. Unplug the air conditioner in order to avoid the risk of child entrapment. It must be noticed that air conditioner system contains refrigerants, which require speciali- zed waste disposal. The...

  • Page 7

    3. If the fuse of indoor unit on pc board is broken,please change it with the type of t. 3.15a/ 250v. Do not obstruct or cover the ventilation grille of the air conditoner.Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air condit...

  • Page 8

    Cautions strict enforcement safety instruction installation warning please read the following safety instructions carefully prior to use. The instructions are classified into two levels, warning and caution according to the seriousness of possible risks and damages as follows. Compliance to the inst...

  • Page 9

    Cautions warning when abnormality such as burnt-small found, immediately stop the operation button and contact sales shop. Off use an exclusive power source with a circuit breaker enforcement connect power supply cord to the outlet completely use the proper voltage do not use power supply cord in a ...

  • Page 10

    5 parts and functions indoor unit outlet inlet connecting piping and electrical wiring drain hose outdoor unit actual inlet grille may vary from the one shown in the manual according to the product purchased display board inlet air purifying filter horizontal flap (adjust up and down air flow. Don't...

  • Page 11

    6 parts and functions note: cooling only unit do not have displays and functions related with heating on/off temp mode set fan timer swing clock sleep lock reset 5 6 7 8 9 10 19 20 21 22 23 4 1 2 3 11 12 13 14 15 16 a u t o on off am pm o c 17 18 24 health 1. Operation mode display 2. Swing display ...

  • Page 12

    7 parts and functions on/off temp mode set fan timer swing clock sleep lock reset 5 6 7 8 9 10 19 20 21 22 23 1 2 3 11 12 13 14 15 16 a u t o on off am pm o c 17 18 1. Operation mode display 2. Swing display 3. Fan speed display lo med hi auto 5. Sleep display 6. Lock display 7. Signal sending displ...

  • Page 13

    8 operation remote controller's operation when in use, put the signal transmission head directly to the receiver hole on the indoor unit. The distance between the signal transmission head and the receiver hole should be within 7m without any obstacle as well. Don't throw the controller, prevent it f...

  • Page 14

    9 operation hints remote controller can memorize settings in each operation mode. To run it next time just select the operation mode and it will start with the previous setting. No reelecting is needed.(timer on/off 、sleep、swing needs reelecting) cautions: note: on cooling only unit, heating mode is...

  • Page 15

    Press mode button. For each press, operation 10 operation (1) unit start mode changes as follows: press on/off button, unit starts. Previous operation status appears on display. (not timer setting) (2) select operation mode (3) select temp. Setting press temp button. Every time the button is pressed...

  • Page 16

    Press mode button. For each press, operation 11 operation (1) unit start mode changes as follows: press on/off button, unit starts. Previous operation status appears on display. (not timer setting) (2) select operation mode unit will run in operation mode displayed on lcd. Stop display at your desir...

  • Page 17

    Press mode button. For each press, operation 12 operation (1) unit start mode changes as follows: press on/off button, unit starts. Previous operation status appears on display. (not timer setting) (2) select operation mode (3) select temp. Setting press temp button. Every time the button is pressed...

  • Page 18

    13 operation hints fan operation in fan operation mode, the unit will not operate in cool or heat mode but only in fan mode. Auto is not available in fan mode,and temp .Setting is disabled. In fan mode,sleep operation is not available. Press mode button. For each press, operation (1) unit start mode...

  • Page 19

    14 operation on/off temp set timer clock swing sleep lock reset fan mode health 1.Status display of air sending horizontal flap ( auto swing ) 2.Up and down air flow direction(use remote controller) pos.4 remote controller blank move the vertical blade by a knob on air conditioner to adjust left and...

  • Page 20

    Comfortable sleep operation power failure resume function if the unit is started for the first time, the compressor will not start running unless 3 minutes have elapsed. When the power resumes after power failure, the unit will run automatically, and 3 minutes later the compressor starts running. Be...

  • Page 21

    Operation health operation 16 2.Health anion function air conditioner is operating the healthy function. Press the on/off switch press the " health"once, " " is displayed, now the 1.Unit start press the " health"again, then the healthy function stops. The anion generator in the air conditioner can g...

  • Page 22

    17 operation you can let unit start or stop automatically at following times: before you wake up in the morning, or get back from outside or after you fall asleep at night. Set clock correctly before starting timer operation timer on/off (1)after unit start, select your desired operation mode. Opera...

  • Page 23

    18 operation to cancel timer mode (1)after unit start, select your desired operation mode operation mode will be displayed on lcd. Every time the button is pressed, display changes as follows: (2) press timer button to change timer mode. Select timer on-off. "on" will flash. (3)time setting for time...

  • Page 24

    Emergency operation: pi pi 19 emergency operation and test operation operation use this operation only when the remote controller is defective or lost. When the emergency operation switch is pressed, the " pi "sound is heard once, which means the start of this operation. Temperature is below 16 o c,...

  • Page 25

    For smart use of the air conditioner setting of proper room temperature close doors and windows during operation if the unit is not to be used for a long time, turn off the power supply main switch. Use the timer effectively use the louvers effectively do not block the air inlet or outlet maintenanc...

  • Page 26

    For smart use of the air conditioner warning air filter cleaning open the inlet grille by pulling it upward. Remove the filter. Clean the filter. Attach the filter. Close the inlet grille. Push up the filter's center tab slightly until it is released from the stopper, and remove the filter downward....

  • Page 27

    22 maintenance 1.Open the lnlet grille 2.Detach the standard air filter 3.Attach air purifying filter 4.Attach the standard air filter (necessary installation) 5.Close the inlet grille close the grille surely slide the knob slightly upward to release the filter, then withdraw it. Put air purifying f...

  • Page 28

    23 trouble shooting before asking for service, check the following first. Normal performance inspection noise is heard phenomenon cause or check points the system does not restart immediately. Smells are generated. Mist or steam are blown out. Multiple check poor cooling application temp. Range of a...